Parameter Numbers During Initial Parameter Error - Mitsubishi MELDAS MDS-C1 Instruction Manual

Ac servo/spindle
Table of Contents

Advertisement

6-4-3

Parameter numbers during initial parameter error

If an initial parameter error (alarm 37) occurs, the alarm and the number of the parameter that may
have been set exceeding the setting range will appear on the CNC Diagnosis screen. (For M60S, E60
Series NC.)
S02 Initial parameter error
If an error number larger than the servo parameter number is displayed for the servo drive unit
(MDS-C1-V1/V2), the alarm is occurring for several related parameters. Refer to the following table,
and correctly set the parameters.
Error parameter No.
2301
2302
2304
2305
6. Troubleshooting
: Error parameter
: Axis name
Details
The following settings are overflowing.
Electronic gears
Position loop gain
Speed feedback
The absolute position parameter is valid when
OSE104 and OSE105 are connected.
The servo option is not available. The SHG control
function is set.
The servo option is not available. The adaptive filter
function is set.
6 - 43
Related parameters
SV001, SV002
SV003, SV018
SV019, SV020
SV049
SV017, SV025
SV057, SV058
SV027