Mitsubishi MELDAS MDS-C1 Instruction Manual page 215

Ac servo/spindle
Table of Contents

Advertisement

bit8. Torque limit 1 (TL1)
bit9. Torque limit 2 (TL2)
bitA. Torque limit 3 (TL3)
This signal is used to temporarily reduce the spindle motor's output torque such as when clamping
the spindle motor on the machine side. The torque limit is designated in percentage using the
motor's short-time rating as 100%.
Set the SP021, SP049 to SP054 torque limit value with a combination of TL1 to 3.
TL3
TL2
0
0
0
1
0
1
1
0
bitF. Cutting (G1)
This signal is used to determine whether cutting is taking place or not during C-axis control.
(2) Spindle control input 2
Spindle control input 2 is not used.
Name
Spindle control input 2
5. Spindle Adjustment
TL1
Torque limit value
1
SP021
0
SP049
1
SP050
0
SP051
F
E
D
C
B
A
bit
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
5 - 5
TL3
TL2
TL1
1
0
1
1
1
0
1
1
1
Details
9
8
7
6
5
4
Details
Torque limit value
SP052
SP053
SP054
3
2
1
0

Hide quick links:

Advertisement

Table of Contents
loading