Appendix 4. Servo/spindle drive unit categories based on higher harmonic suppression countermeasure guidelines
Appendix 4-1 Servo/spindle drive unit circuit categories based on higher
harmonic suppression countermeasure guidelines
Refer to the following table and calculate the circuit category (conversion coefficient) and the power
capacity based on higher harmonic suppression countermeasure guidelines.
Circuit category
Name
TRS Series
MR-S1/S2/S3
MR-S11/12 Series
AC servo
drive unit
MDS-A-SVJ
MDS-B-SJV2
MR-J2-CT Series
MDS-A-V1/V2
MDS-B-V1/V14/V2/V24
MDS-C1-V1/V2 Series
SFJ/SGJ Series
MDS-A-SPJ
MDS-B-SPJ2 Series
AC spindle
drive unit
MDS-A-CSP-370/450
MDS-A-SP/SPA
MDS-B-SP/SPA/SPH/SPM/SPX
MDS-C1-SP/SPH/SPM/SPX Series
Usage conditions: The power supply unit (MDS-A/B/C1-CV Series) applies when using the AC
Power facility capacity
Type
MDS-A/B/C1-SP-37
MDS-A/B/C1-SP-55
MDS-A/B/C1-SP-75
MDS-A/B/C1-SP-110
MDS-A/B/C1-SP-150
MDS-A/B/C1-SP-185
MDS-A/B/C1-SP-220
MDS-A/B/C1-SP-260
MDS-A/B/C1-SP-300
MDS-B-SP-370
MDS-B-SP-450
MDS-B-SP-550
SP: Including SPA/SPH/SPM/SPX
Model
reactor (B-AL Series). When using the MDS-A-CR Series, calculate using the
conversion coefficient K31 = 3.4 (no reactor).
Rated
capacity
[kVA]
4.61
MDS-A/B/C1-V1-03
6.77
MDS-A/B/C1-V1-05
9.07
MDS-A/B/C1-V1-10
13.1
MDS-A/B/C1-V1-20
17.6
MDS-A/B/C1-V1-35
21.8
MDS-A/B/C1-V1-45
25.9
MDS-A/B/C1-V1-70
30.0
MDS-A/B/C1-V1-90
34.7
42.8
52.1
63.7
V1: Including V14
Circuit
category
3-phase bridge
3
(smoothing capacitor)
with no reactor
3-phase bridge
3
(smoothing capacitor)
with no reactor
3-phase bridge
3
(smoothing capacitor)
with no reactor
3-phase bridge
3
(smoothing capacitor)
with AC reactor
3-phase bridge
3
(smoothing capacitor)
with no reactor
3-phase bridge
3
(smoothing capacitor)
with no reactor
3-phase bridge
3
(smoothing capacitor)
with no reactor
3-phase bridge
3
(smoothing capacitor)
with no AC reactor
Rated
Type
capacity
[kVA]
0.6
1.0
1.6
2.7
4.7
5.9
9.0
11.5
A4 - 2
Conversion
Circuit type
coefficient
K31 = 3.4
K31 = 3.4
K31 = 3.4
K32 = 1.8
K31 = 3.4
K31 = 3.4
K31 = 3.4
K32 = 1.8
Type
MDS-A/B/C1-V2-0503
MDS-A/B/C1-V2-0505
MDS-B/C1-V2-1003
MDS-A/B/C1-V2-1005
MDS-A/B/C1-V2-1010
MDS-A/B/C1-V2-2010
MDS-A/B/C1-V2-2020
MDS-A/B/C1-V2-3510
MDS-A/B/C1-V2-3520
MDS-A/B/C1-V2-3535
MDS-A/B/C1-V2-4520
MDS-A/B/C1-V2-4535
MDS-C1-V2-4545
MDS-C1-V2-7070
V2: Including V24
Rated
capacity
[kVA]
1.6
2.0
2.2
2.6
3.2
4.3
5.4
6.3
7.4
9.4
8.6
10.6
11.8
18.0

Hide quick links: