  • Page 2 Introduction This manual covers the items required for installing, connecting and setting up the MITSUBISHI CNC. Supported models are as follows: Supported models Abbreviations in this manual M800S Series M850S, M830S M80 Series M80 TypeA, M80 TypeB E80 Series E80 TypeA, E80 TypeB...
  • Page 3 CAUTION For items described as "Restrictions" or "Usable State" in this manual, the instruction manual issued by the machine tool builder takes precedence over this manual. Items that are not described in this manual must be interpreted as "not possible". This manual is written on the assumption that all the applicable functions are included.
  • Page 5 Manual List Manuals related to M800/M80/E80/C80 Series are listed as follows. These manuals are written on the assumption that all optional functions are added to the targeted model. Some functions or screens may not be available depending on the machine or specifications set by MTB. (Confirm the specifications before use.) The manuals issued by MTB take precedence over these manuals.
  • Page 6 Manuals for MTBs (NC) Manual IB No. Purpose and Contents  Model selection M800/M80/E80/C80 Series IB-1501505 Specifications Manual (Function)  Outline of various functions  Model selection M800/M80/E80/C80 Series IB-1501506 Specifications Manual (Hardware)  Specifications of hardware unit  Detailed specifications of hardware unit M800W/M80W Series IB-1501268 Connection and Setup Manual...
  • Page 7 (Monitor) GOT2000 Series Connection  Outline of connection types and connection method between Manual (Mitsubishi Electric SH-081197 GOT and Mitsubishi Electric connection devices Products) GT Designer3 (GOT2000) Screen  Outline of screen design method using screen creation SH-081220 Design Manual software GT Designer3 ■...
  • Page 8 ■ For C80 Series Manual Purpose and Contents MELSEC iQ-R Module Configuration  Outline of system configuration, specifications, installation, SH-081262 Manual wiring, maintenance, etc. MELSEC iQ-R CPU Module User’s  Outline of specifications, procedures before operation, SH-081263 Manual (Startup) troubleshooting, etc. for CPU module MELSEC iQ-R CPU Module User’s ...
  • Page 10 Precautions for Safety Always read this manual and enclosed documents before installation, operation, maintenance and inspection to ensure correct usage. Thoroughly understand the basics, safety information and precautions of the devices before using. This manual classifies the safety precautions into "DANGER", "WARNING" and "CAUTION". DANGER When the user could be subject to imminent fatalities or serious injuries if handling is mistaken.
  • Page 11 For Safe Use Mitsubishi CNC is designed and manufactured solely for applications to machine tools to be used for industrial purposes. Do not use this product in any applications other than those specified above, especially those which are substantially influential on the public interest or which are expected to have significant influence on human lives or properties.
  • Page 12 2. Items related to prevention of fire CAUTION Install the controller, drive unit, motor and regenerative resistor on non-combustible material. Installation directly on or near combustible materials could result in fires. If any malfunction in the unit is observed, shut off the power at the unit’s power supply side. Continuous flow of large current could result in fires.
  • Page 13 4. General precautions Always follow the precautions below. Incorrect handling could result in faults, injuries or electric shocks, etc. (1) Items related to product and manual CAUTION For items described as "Restrictions" or "Usable State" in this manual, the instruction manual issued by the machine tool builder takes precedence over this manual.
  • Page 14 CAUTION Do not block the intake/outtake ports of the motor with the cooling fan. Install the controller’s display section and operation board section on the spot where cutting oil will not reach. The controller, drive unit and motor are precision devices, so do not drop or apply thumping vibration and strong impacts on them.
  • Page 15 (3) Items related to wiring CAUTION Correctly wire this product. Failure to observe this could result in motor runaway, etc. Incorrect terminal connections could cause the devices to rupture or damage, etc. Do not install a phase advancing capacitor, surge absorber or radio noise filter on the output side of the drive unit.
  • Page 16 CAUTION Separate the signal wire from the drive line or power line when wiring. Carry out wiring so that there is no possibility of short circuit between wires, nor of dangerous state. Use wires and cables whose wire diameter, heat resistance level and bending capacity are compatible with the system.
  • Page 17 (4) Set up WARNING Do not cancel the emergency stop before confirming the basic operation. Always set the stroke end and stroke limit. Failure to set this could result in collision with the machine end. CAUTION If the descriptions relating to the "restrictions" and "allowable conditions" conflict between this manual and the machine tool builder's instruction manual.
  • Page 18 (6) Usage CAUTION Use this product within the range of environmental condition described in this manual. Using this product in an environment outside the range could result in electric shock, fire, operation failure, or damage to or deterioration of the product. Install an external emergency stop circuit so that the operation can be stopped and the power turns OFF immediately when unforeseen situation occurs.
  • Page 19 The electrolytic capacitor’s capacity will drop due to deterioration. To prevent secondary damage due to capacitor’s faults, Mitsubishi recommends the electrolytic capacitor to be replaced approx. every five years even when used in a normal environment. Contact the Service Center for replacements.
  • Page 20 (9) Disposal CAUTION Take the batteries and backlights for LCD, etc., off from the controller, drive unit and motor, and dispose of them as general industrial wastes. Do not alter or disassemble controller, drive unit, or motor. Collect and dispose of the spent batteries and the backlights for LCD according to the local laws. (10) General precautions To explain the details, drawings given in the instruction manual, etc., may show the unit with the cover or safety partition removed.
  • Page 22 (2) Requirements for "Law for Treatment of Waste and Cleaning" (a) Mitsubishi recommends recycling and selling the product when no longer needed according to item (1) above. The user should make an effort to reduce waste in this manner.
  • Page 24 This symbol mark is according to the directive 2006/66/EC Article 20 Information for end- users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.
  • Page 26 MELDAS, MELSEC, EZSocket, EZMotion, iQ Platform, MELSEC iQ-R, MELSOFT, GOT, CC-Link, CC-Link/LT, CC-Link IE, CC-Link IE/field, EcoMonitorLight and SLMP are either trademarks or registered trademarks of Mitsubishi Electric Corporation in Japan and/or other countries. Ethernet is a registered trademark of Xerox Corporation in the United States and/or other countries.
  • Page 28 本製品の取扱いについて ( 日本語 /Japanese) 本製品は工業用 ( クラス A) 電磁環境適合機器です。販売者あるいは使用者はこの点に注意し、住商業環境以外で の使用をお願いいたします。 Handling of our product (English) This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 본...
  • Page 30: Table Of Contents

    3.14 Communication Expansion Unit ..........................21 3.15 Manual Pulse Generator ............................22 3.16 Synchronous Feed Encoder..........................22 3.17 MITSUBISHI CNC Machine Operation Panel [M800S/M80]................. 22 3.18 MITSUBISHI CNC Machine Operation Panel [E80]....................23 3.19 Handy Terminal..............................23 3.20 Cable Connector Sets ............................23 3.21 Thermistor Sets..............................
  • Page 31 4.18 Handy Terminal ..............................185 4.19 Thermistor................................189 4.19.1 Thermistor(PT3C-51F-M2)......................... 189 4.20 Exclusive SD Cards for MITSUBISHI CNC ......................190 4.21 Specifications and Precautions of USB/SD/LAN Interface ................191 4.21.1 USB Interface (Memory I/F card) ....................... 191 4.21.2 SD Interface (Memory I/F card)........................192 4.21.3 LAN Interface (Control Unit)........................
  • Page 32 6 Precautions for Connecting ........................219 6.1 Precautions for Wiring............................220 6.1.1 Precautions when Connecting/Disconnecting Cables .................. 220 6.1.2 Precautions for Using Optical Communication Cable................... 223 6.1.3 Precautions for Connecting 24V Power Supply ................... 224 6.2 Turning the Power ON/OFF ..........................225 7 Connection of Control Unit ........................
  • Page 33 12.1 Synchronous Feed Encoder Connection System Drawing................. 326 12.2 Connecting with Control Unit ..........................326 13 Connection of MITSUBISHI CNC Machine Operation Panel .............. 327 13.1 Machine Operation Panel Connection System Drawing..................328 13.2 Connecting with Power Supply ........................... 329 13.3 Connecting with Frame Ground..........................
  • Page 34 15.3.10 J396 Cable ............................... 369 15.3.11 MR-BKS1CBL-A1-H / MR-BKS1CBL-A2-H Cable ................... 370 15.3.12 MR-BT6V2CBL Cable ..........................370 15.3.13 MR-D05UDL3M-B Cable .......................... 371 15.3.14 MR-PWS1CBL-A1-H / MR-PWS1CBL-A2-H Cable ................. 371 15.3.15 SH21 Cable .............................. 372 15.4 List of Cable Connector Sets ..........................373 16 Setup Outline............................
  • Page 35 20.9.2 Setting Device Points ..........................440 20.9.3 Setting Common Pointer No........................441 20.9.4 Setting Program Executing Order ......................442 20.10 Writing a Sequence Program with GX Works2....................443 20.11 Writing a Sequence Program to ROM with GX Works2 ................... 446 20.12 Setting the PLC Parameters ..........................
  • Page 36 26.2.2 Procedure of Setting Backlash Compensation II ..................514 26.2.2.1 Setting the backlash compensation II acceleration rate ..............514 26.2.2.2 Setting compensation amount of backlash compensation II.............. 515 26.2.2.3 Precautions for setting parameters....................516 27 Confirming the Spindle Operation......................519 27.1 In Manual Operation (with Manual Numerical Command) ..................
  • Page 37 37.6 EMC Countermeasure Parts..........................583 37.6.1 Shield Clamp Fitting ........................... 583 37.6.2 Ferrite Core ..............................584 37.6.3 Surge Absorber ............................585 37.6.4 Selection of Stabilized Power Supply......................587 38 Appx.5: Restrictions for Lithium Batteries ..................589 38.1 Restriction for Packing............................590 38.1.1 Target Products............................
  • Page 38: System Basic Configuration

    System Basic Configuration IB-1501269-J...
  • Page 39: System Basic Configuration Drawing

    M800S/M80/E80 Series Connection and Setup Manual 1 System Basic Configuration 1.1 System Basic Configuration Drawing Display unit Keyboard unit (Control unit is added onto back of display unit.) (Operation panel I/O unit is added onto back of keyboard unit.) Control unit Operation panel I/O unit Remote I/O unit Manual pulse penerator...
  • Page 40: General Connection Diagram

    General Connection Diagram IB-1501269-J...
  • Page 41: General Connection Diagram [M800S]

    (R2-TM) (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 42 (R2-TM) (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 43: General Connection Diagram [M80]

    (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the 8.4-type display unit, TP connector is not used. (Note 3) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 44 (Note 3) The safety remote I/O unit is available only when the functional safety expansion unit is mounted. (Note 4) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 45 (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the 8.4-type display unit, TP connector is not used. (Note 3) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 46 (Note 3) The safety remote I/O unit is available only when the functional safety expansion unit is mounted. (Note 4) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 47: General Connection Diagram [E80]

    (R2-TM) (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 48 (R2-TM) (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 49: Connecting A Pulse-Controlled Inverter

    J303 (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 50 J303 (Note 1) For information on how to connect the drive unit, refer to the drive unit's manual. (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel".
  • Page 51 M800S/M80/E80 Series Connection and Setup Manual 2 General Connection Diagram IB-1501269-J...
  • Page 52: List Of Configuration

    List of Configuration IB-1501269-J...
  • Page 53: Control Unit [M800S]

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.1 Control Unit [M800S] Classification Type Components Remarks NC functions Base control card Export Trade Control Order noncompliant unit and and display controller FCU8-MU542 Add-on CPU card Foreign Exchange Order noncompliant unit For M830S Front-side memory I/F card NC functions...
  • Page 54: Display Unit [M800S]

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.4 Display Unit [M800S] Classification Type Components Remarks LCD panel Menu keys 10.4-type color TFT touch panel Escutcheon Front side memory I/F is normally equipped with FCU8-DU141-31 (VGA:640*480) Base metal plate the control unit Cable Screw cap set...
  • Page 55: Keyboard Unit [M800S]

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.7 Keyboard Unit [M800S] Classification Type Components Remarks Escutcheon, key switch Keyboard for 10.4-type display unit FCU8-KB041 G402 cable ONG layout (for L system, XZF) Clear keys Screw cap set Escutcheon, key switch Keyboard for 10.4-type display unit FCU8-KB046...
  • Page 56: Operation Panel I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.10 Operation Panel I/O Unit Classification Type Components Remarks DI: 64-points 24V/0V common type DO: 48-points source type (200mA/point) AO: 1 point Manual pulse generator input: 2ch DI 24V/0V common input [64 points] Control unit I/F Base card DO Source output [48 points]...
  • Page 57: Remote I/O Unit [M800S/M80]

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.11 Remote I/O Unit [M800S/M80] Classification Type Components Remarks DI: 32-points 24V/0V common type DI 24V/0V common input [32 points] Base card FCU8-DX220 Do: 32-points source type (200mA/point) DO Source output [32 points] RIO 2.0 connector set Number of occupied stations: 1 DI: 64-points 24V/0V common type...
  • Page 58: Remote I/O Unit [E80]

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.12 Remote I/O Unit [E80] Classification Type Components Remarks DI: 32-points 24V/0V common type DI 24V/0V common input [32 points] Base card FCU8-DX220 Do: 32-points source type (200mA/point) DO Source output [32 points] RIO 2.0 connector set Number of occupied stations: 1 DI: 64-points 24V/0V common type...
  • Page 59: Manual Pulse Generator

    OSE1024-3-15-68-8 OSE1024-3-15-68-8 1024pulse/rev 8000r/min ,68-square flange Input 5VDC Synchronous feed encoder OSE1024-3-15-160 OSE1024-3-15-160 1024pulse/rev 6000r/min, 160-square flange 3.17 MITSUBISHI CNC Machine Operation Panel [M800S/M80] Classification Type Components Remarks Escutcheon, key switch Main panel A MITSUBISHI standard key layout (55 keys) FCU8-KB921 control card (For 8.4-type/15-type display unit)
  • Page 60: Mitsubishi Cnc Machine Operation Panel [E80]

    M800S/M80/E80 Series Connection and Setup Manual 3 List of Configuration 3.18 MITSUBISHI CNC Machine Operation Panel [E80] Classification Type Components Remarks Escutcheon, key switch Main panel A Custom specification key layout (55 keys) FCU8-KB922 control card (For 8.4-type/15-type display unit)
  • Page 61: Thermistor Sets

    Components Remarks Thermistor PT3C-51F-M2 10P Thermistor (PT3C-51F-M2,10pcs.) 3.22 Genuine Memory Card Classification Type Components Remarks Exclusive SD cards for MITSUBISHI CNC FCU8-SD001G FCU8-SD001G 1GB capacity Exclusive SD cards for MITSUBISHI CNC FCU8-SD004G FCU8-SD004G 4GB capacity 3.23 Durable Parts Durable parts...
  • Page 62: List Of Cables

    Synchronous encoder - control unit (straight, with connector) FCUA-R054-xM Synchronous encoder - control unit (right angle, with connector) 3, 5, 10, 15, 20 G071 LxM 24VDC relay cable for MITSUBISHI CNC machine operation panel 0.12, 0.5, 1 G123 Cable for emergency stop release G430 LxM...
  • Page 63: System Type

    Control unit Display unit FCA850H-8S FCU8-DU181-31 (15-type color LCD touchscreen) M850S FCU8-MA542-001 FCA850H-4S FCU8-DU141-31 (10.4-type color LCD touchscreen) M800S Series FCA830H-8S FCU8-DU181-31 (15-type color LCD touchscreen) M830S FCU8-MU542-001 FCA830H-4S FCU8-DU141-31 (10.4-type color LCD touchscreen) FCA80H-8A FCU8-DU181-32 (15-type color LCD touchscreen)
  • Page 64: General Specifications

    General Specifications IB-1501269-J...
  • Page 65: Environment Conditions [M800S]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.1 Environment Conditions [M800S] 4.1.1 Installation Environment Conditions Unit name Control unit Display unit Item FCU8-MU542/MA542 FCU8-DU141-31 : (10.4-type) Type FCU8-MU541/MA541 FCU8-DU181-31 : (15-type) During 0 to 58°C operation Ambient temperature During -20 to 60°C storage...
  • Page 66 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Unit name Keyboard unit Operation panel I/O unit Machine operation panel FCU8-KB041/KB046 : (10.4-type) FCU8-KB921/KB922/ FCU8-KB047 : (10.4-type/vertical FCU8-DX731 KB925 Item arrangement) FCU8-DX750 Type FCU8-DX834 FCU8-KB923/KB924/ FCU8-KB048 : (10.4-type) FCU8-DX760 KB926 FCU8-KB083 : (15-type/vertical FCU8-DX761 FCU8-KB931/KB941...
  • Page 67 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Unit name Remote I/O unit FCU8-DX213/ FCU8-DX220/ Item DX213-1/ Type DX230/ FCU8-DX202 FCU8-DX408 FCU8-DX409 FCU8-DX651 DX654/ DX231 DX654-1 During 0 to 58°C operation Ambient temperature During -20 to 60°C storage Long term 10 to 75% RH (with no dew condensation) 10 to 85% RH Ambient...
  • Page 68: 24Vdc Stabilized Power Supply Selecting Conditions

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.1.2 24VDC Stabilized Power Supply Selecting Conditions Consider the following characteristics for the stabilized power supply, and select the power supply that complies with laws, regulations, or safety standards of the country where the machine will be installed. Item Specifications Remarks...
  • Page 69: Environment Conditions [M80]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.2 Environment Conditions [M80] 4.2.1 Installation Environment Conditions Unit name Control unit Display unit FCU8-DU121-12 : (8.4-type) Item FCU8-MU511/MU512 Type FCU8-DU141-32 : (10.4-type) FCU8-MU501/MU502 FCU8-DU181-32 : (15-type) During 0 to 58°C operation Ambient temperature...
  • Page 70 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Unit name Keyboard unit Operation panel I/O unit Machine operation panel FCU8-KB026/KB028 : (8.4-type) FCU8-KB029 : (8.4-type/vertical arrangement) FCU8-KB921/KB922/ FCU8-DX731 FCU8-KB041/KB046 : (10.4-type) KB925 Item FCU8-DX750 Type FCU8-KB047 : (10.4-type/vertical FCU8-DX834 FCU8-KB923/KB924/ FCU8-DX760 arrangement)
  • Page 71 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Unit name Remote I/O unit FCU8-DX213/ FCU8-DX220/ Item DX213-1/ Type DX230/ FCU8-DX202 FCU8-DX408 FCU8-DX409 FCU8-DX651 DX654/ DX231 DX654-1 During 0 to 58°C operation Ambient temperature During -20 to 60°C storage Long term 10 to 75% RH (with no dew condensation) 10 to 85% RH Ambient...
  • Page 72: 24Vdc Stabilized Power Supply Selecting Conditions

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.2.2 24VDC Stabilized Power Supply Selecting Conditions Consider the following characteristics for the stabilized power supply, and select the power supply that complies with laws, regulations, or safety standards of the country where the machine will be installed. Item Specifications Remarks...
  • Page 73: Environment Conditions [E80]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.3 Environment Conditions [E80] 4.3.1 Installation Environment Conditions Unit name Control unit Display unit Item FCU8-MU513 Type FCU8-DU121-13 : (8.4-type) FCU8-MU514 During 0 to 58°C operation Ambient temperature During -20 to 60°C storage Long term 10 to 75% RH (with no dew condensation)
  • Page 74 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Unit name Keyboard unit Operation panel I/O unit Machine operation panel FCU8-DX731 Item FCU8-KB024 FCU8-DX750 FCU8-KB922/KB925 Type FCU8-DX834 FCU8-KB025 FCU8-DX760 FCU8-KB941 FCU8-DX761 During 0 to 58°C operation Ambient temperature During -20 to 60°C storage Long term 10 to 75% RH (with no dew condensation)
  • Page 75 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Unit name Remote I/O unit FCU8-DX220/ Item FCU8-DX213/ Type DX230/ FCU8-DX202 FCU8-DX408 FCU8-DX409 DX213-1 DX231 During 0 to 58°C operation Ambient temperature During -20 to 60°C storage Long term 10 to 75% RH (with no dew condensation) Ambient humidity Short term...
  • Page 76: 24Vdc Stabilized Power Supply Selecting Conditions

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.3.2 24VDC Stabilized Power Supply Selecting Conditions Consider the following characteristics for the stabilized power supply, and select the power supply that complies with laws, regulations, or safety standards of the country where the machine will be installed. Item Specifications Remarks...
  • Page 77: Control Unit [M800S]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.4 Control Unit [M800S] 4.4.1 FCU8-MU542 / FCU8-MA542 / FCU8-MU541 / FCU8-MA541 [Outline dimension] [mm] 239.1 214.5 IB-1501269-J...
  • Page 78 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] (22) (21) (12) (14) (11) (13) (15) (16) (17) (18) (19) (20) [Cover opened] (23) Arrow  A (10) Connector Connector Function Function name name USB_F Front-side USB memory I/F (13) RIO2 Remote I/O 2.0 communication USB_B (14) MENUKEY...
  • Page 79 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc. Connect the cables to the designated connectors. Incorrect connections could damage the device. 12V, 5V, and 3.3V output from connectors are to supply the power for dedicated peripheral devices.
  • Page 80 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (6) DCIN (24VDC input) +24V <Cable side connector type> Connector : 2-178288-3 Contact : 1-175218-5 Recommended manufacturer : Tyco Electronics (a) Specifications of power supply Consider the following characteristics when selecting the stabilized power supply (prepared by machine tool builder).
  • Page 81 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (7) EMG (External emergency stop input) EMG IN +24V <Cable side connector type> Connector : 50-57-9403 Contact : 0016020103 Recommended manufacturer : MOLEX (Note) Use this when installing an emergency stop switch in the electric cabinet. Connect a terminator (G123 cable) when not using this connector.
  • Page 82 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (12) RIO1 (Remote I/O 2.0 communication 1st channel) (13) RIO2 (Remote I/O 2.0 communication 2nd channel) Up to 64 remote I/O stations can be connected. 1 2 3 TXRXD TXRXD* <Cable side connector type> Connector : 1-1318119-3 Contact : 1318107-1 Recommended manufacturer : Tyco Electronics...
  • Page 83 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Input for synchronous feed encoder Specification of input part Three phases (A phase, B phase, a phase difference 90 degrees, Number of pulse phases Z phase) (Refer to the waveform below.) Signal output of the encoder RS422 differential driver output Input voltage range...
  • Page 84 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Input/output circuit Connector pin No. HA1A HA2A Signal input HA1B HA2B Control circuit Power output When using the synchronous feed encoder and the manual pulse generator at the same time, connect the manual pulse generator to the operation panel I/O unit or use a distribution cable made by the machine tool builder.
  • Page 85 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Skip signal input conditions Use the input signal within the following condition ranges. 24V common 0V common Input voltage at external contact ON 6V or less 18V or more, 25.2V or less Input current at external contact ON 6mA or more Input voltage at external contact OFF...
  • Page 86 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (17) SIO (RS-232C communication 2ch) RD1(RXD1) SD1(TXD1) CS1(CTS1) RS1(RTS1) DR1(DSR1) ER1(DTR1) RD2(RXD2) SD2(TXD2) CS2(CTS2) RS2(RTS2) DR2(DSR2) ER2(DTR2) - Connect connector case with FG pattern. <Cable side connector type> Plug : 10120-3000PE Shell : 10320-52F0-008 Recommended manufacturer : 3M (Note)
  • Page 87 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (18) LAN1 (Ethernet communication) TXRXD0+ TXRXD0- TXRXD1+ TXRXD2+ TXRXD2- TXRXD1- TXRXD3+ TXRXD3- - Connect connector case with FG pattern. - Use J303 cable when directly connecting a device such as a personal computer to the unit. <Cable side connector type>...
  • Page 88 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Lamp state Details Lit (Green) 24VDC power is being supplied from the external power supply. The following may have caused an error: 24VIN - No 24VDC-power supply from the external power supply. Not lit - Disconnection of fuse near DCIN connector.
  • Page 89: Control Unit [M80]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.5 Control Unit [M80] 4.5.1 FCU8-MU511 / FCU8-MU512 / FCU8-MU501 / FCU8-MU502 [Outline dimension] [mm] 239.1 214.5 IB-1501269-J...
  • Page 90 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] (22) (21) (12) (14) (10) (11) (13) (15) (16) (17) (18) (19) (20) (23) Arrow A Connector Connector Function Function name name USB_F Front-side USB memory I/F (13) RIO2 Remote I/O 2.0 communication USB_B (14) MENUKEY Menu key I/F...
  • Page 91 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Lamp state Details Lit (Green) 24VDC power is being supplied from the external power supply. The following may have caused an error: 24VIN - No 24VDC-power supply from the external power supply. Not lit - Disconnection of fuse near DCIN connector.
  • Page 92: Control Unit [E80]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.6 Control Unit [E80] 4.6.1 FCU8-MU513 / FCU8-MU514 [Outline dimension] [mm] 239.1 214.5 IB-1501269-J...
  • Page 93 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] (22) (21) (12) (14) (10) (11) (13) (15) (16) (17) (18) (19) (20) Connector Connector Function Function name name USB_F Front-side USB memory I/F (13) RIO2 Remote I/O 2.0 communication USB_B (14) MENUKEY Menu key I/F...
  • Page 94 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (12) RIO1 (Remote I/O 2.0 communication 1st channel) (13) RIO2 (Remote I/O 2.0 communication 2nd channel) For E80, RIO1 and RIO2 connectors can be used as interfaces to output pulses. With this function, you can connect a pulse-controlled inverter with RS422 interface to E80.
  • Page 95 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Lamp state Details Lit (Green) 24VDC power is being supplied from the external power supply. The following may have caused an error: 24VIN - No 24VDC-power supply from the external power supply. Not lit - Disconnection of fuse near DCIN connector.
  • Page 96: Display Unit [M800S]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.7 Display Unit [M800S] 4.7.1 10.4-type (FCU8-DU141-31) [Outline dimension] [mm] (Space required for wiring) Option relay unit Option relay unit, Option relay unit, not mounted FCU8-EX702 mounted FCU8-EX703 mounted (Space required for wiring) (Note) The figure above shows the state with the control unit mounted.
  • Page 97 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Panel cut dimension] [mm] (Unit outline) 276±0.3 2±0.2 272±0.3 4-M3 screw (Square hole dimension) IB-1501269-J...
  • Page 98: 15-Type (Fcu8-Du181-31)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.7.2 15-type (FCU8-DU181-31) [Outline dimension] [mm] (Space required for wiring) Option relay unit Option relay unit, Option relay unit, not mounted FCU8-EX702 mounted FCU8-EX703 mounted (Space required for wiring) (Note) The figure above shows the state with the control unit mounted. IB-1501269-J...
  • Page 99 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Panel cut dimension] [mm] (Unit outline) 193±0.3 193±0.3 199±0.3 183±0.3 8-M3 screw 8±0.2 8±0.2 193.5 (Square hole dimension) IB-1501269-J...
  • Page 100: Precautions

    Connection of Frame Ground (FG)".) Otherwise, the reaction and usability of the touchscreen will remarkably deteriorate. [Spot defect of LCD] The display inspection standard at the time of shipment from MITSUBISHI is as follows. Item Reference value Bright spot defect N ≦...
  • Page 101: Display Unit [M80]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.8 Display Unit [M80] 4.8.1 8.4-type (FCU8-DU121-12) [Outline dimension] [mm] (Space required for wiring) Option relay unit Option relay unit, Option relay unit, not mounted FCU8-EX702 mounted FCU8-EX703 mounted (Space required for wiring) (Note 1) The 8.4-type display unit is incompatible with the touchscreen.
  • Page 102 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Panel cut dimension] [mm] (Unit outline) 246±0.3 2±0.2 242±0.3 4-M3 screw (Square hole dimension) IB-1501269-J...
  • Page 103: Type (Fcu8-Du141-32)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.8.2 10.4-type (FCU8-DU141-32) [Outline dimension] [mm] (Space required for wiring) Option relay unit Option relay unit, Option relay unit, not mounted FCU8-EX702 mounted FCU8-EX703 mounted (Space required for wiring) (Note) The figure above shows the state with the control unit mounted. IB-1501269-J...
  • Page 104 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Panel cut dimension] [mm] (Unit outline) 276±0.3 2±0.2 272±0.3 4-M3 screw (Square hole dimension) IB-1501269-J...
  • Page 105: 15-Type (Fcu8-Du181-32)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.8.3 15-type (FCU8-DU181-32) [Outline dimension] [mm] (Space required for wiring) Option relay unit Option relay unit, Option relay unit, not mounted FCU8-EX702 mounted FCU8-EX703 mounted (Space required for wiring) (Note) The figure above shows the state with the control unit mounted. IB-1501269-J...
  • Page 106 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Panel cut dimension] [mm] (Unit outline) 193±0.3 193±0.3 199±0.3 183±0.3 8-M3 screw 8±0.2 8±0.2 193.5 (Square hole dimension) IB-1501269-J...
  • Page 107: Precautions

    Connection of Frame Ground (FG)".) Otherwise, the reaction and usability of the touchscreen will remarkably deteriorate. [Spot defect of LCD] The display inspection standard at the time of shipment from MITSUBISHI is as follows. Item Reference value Bright spot defect N ≦...
  • Page 108: Display Unit [E80]

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.9 Display Unit [E80] 4.9.1 8.4-type (FCU8-DU121-13) [Outline dimension] [mm] (Space required for wiring) Option relay unit Option relay unit, Option relay unit, not mounted FCU8-EX702 mounted FCU8-EX703 mounted (Space required for wiring) (Note 1) The 8.4-type display unit is incompatible with the touchscreen.
  • Page 109: Precautions

    242±0.3 4-M3 screw (Square hole dimension) 4.9.2 Precautions [Spot defect of LCD] The display inspection standard at the time of shipment from MITSUBISHI is as follows. Item Reference value Bright spot defect N ≦ 3 Spot defect Black spot defect N ≦...
  • Page 110: Keyboard Unit

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10 Keyboard Unit (Note) Do not change the setting for the rotary switch mounted on the keyboard unit. If the setting is changed, the keyboard will not work. Type The initial value of the rotary switch FCU8-KB026 FCU8-KB028 FCU8-KB029...
  • Page 111: Keyboard For 8.4-Type Display Unit (Fcu8-Kb026)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.1 Keyboard for 8.4-type Display Unit (FCU8-KB026) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 128±0.3...
  • Page 112: Keyboard For 8.4-Type Display Unit (Fcu8-Kb028)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.2 Keyboard for 8.4-type Display Unit (FCU8-KB028) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 128±0.3...
  • Page 113: Keyboard For 8.4-Type Display Unit (Fcu8-Kb029)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.3 Keyboard for 8.4-type Display Unit (FCU8-KB029) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 248±0.3...
  • Page 114: Keyboard For 10.4-Type Display Unit (Fcu8-Kb041)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.4 Keyboard for 10.4-type Display Unit (FCU8-KB041) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 128±0.3...
  • Page 115: Keyboard For 10.4-Type Display Unit (Fcu8-Kb046)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.5 Keyboard for 10.4-type Display Unit (FCU8-KB046) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 128±0.3...
  • Page 116: Keyboard For 10.4-Type Display Unit (Fcu8-Kb047)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.6 Keyboard for 10.4-type Display Unit (FCU8-KB047) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 278±0.3...
  • Page 117: Keyboard For 10.4-Type Display Unit (Fcu8-Kb048)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.7 Keyboard for 10.4-type Display Unit (FCU8-KB048) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 218±0.3...
  • Page 118: Keyboard For 15-Type Display Unit (Fcu8-Kb083)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.8 Keyboard for 15-type Display Unit (FCU8-KB083) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 200.5±0.3...
  • Page 119: Keyboard For 8.4-Type Display Unit (Fcu8-Kb024)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.9 Keyboard for 8.4-type Display Unit (FCU8-KB024) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 128±0.3...
  • Page 120: Keyboard For 8.4-Type Display Unit (Fcu8-Kb025)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.10.10 Keyboard for 8.4-type Display Unit (FCU8-KB025) [Outline dimension] [mm] (Space required for wiring) (Note) The above side view shows the state with the operation panel I/O unit mounted. [Panel cut dimension] [mm] (Unit outline) 128±0.3...
  • Page 121: Operation Panel I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.11 Operation Panel I/O Unit 4.11.1 List of Units Classification Type Components Remarks DI: 64-points 24V/0V common type DO: 48-points source type (200mA/point) AO: 1 point Manual pulse generator input: 2ch DI 24V/0V common input [64 points] Control unit I/F FCU8-DX731...
  • Page 122: Fcu8-Dx731 / Fcu8-Dx750 / Fcu8-Dx760 / Fcu8-Dx761 / Fcu8-Dx834

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.11.2 FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761 / FCU8-DX834 [Outline dimension : FCU8-DX731] [mm] 99 (Space required for wiring) [Outline dimension : FCU8-DX750] [mm] 99 (Space required for wiring) IB-1501269-J...
  • Page 123 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX760] [mm] 99 (Space required for wiring) [Outline dimension : FCU8-DX761] [mm] 99 (Space required for wiring) IB-1501269-J...
  • Page 124 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX834] [mm] 99 (Space required for wiring) IB-1501269-J...
  • Page 125 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Installation dimension: FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761 / FCU8-DX834] [mm] 116 (Unit outline) 106±0.3 4-M3 screw (Note) The unit thickness of the fixed part with screws is 16.6mm. Select the fixing screws having the length suitable for the thickness. IB-1501269-J...
  • Page 126 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] FCU8-DX731 FCU8-DX750 FCU8-DX760 (13) (12) (12) (11) (15) (10) (10) (13) (13) (12) (15) (15) (17) (16) (21) (16) (21) (16) (21) FCU8-DX761 FCU8-DX834 (19) (12) (12) (10) (13) (13) (14) (15) (21)
  • Page 127 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc. Connect the cables to the designated connectors. Incorrect connections could damage the device. 12V, 5V, and 3.3V output from connectors are to supply the power for dedicated peripheral devices.
  • Page 128 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal input circuit Both 24V common and 0V common connections are allowed in the digital signal input circuit. Follow the wiring diagram below for each type. Input circuit [FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761] 24V common 0V common...
  • Page 129 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Input conditions The input signals must be used within the following condition ranges. [FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761] 24V common 0V common Input voltage at external contact ON 6V or less 18V or more, 25.2V or less Input current at external contact ON 5mA or more...
  • Page 130 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (2) CG32 (Machine signal output) Digital output 32 points (1st station) (4) CG34 (Machine signal output) Digital output 32 points (2nd station) (6) CG36 (Machine signal output) Digital output 16 points (3rd station) (8) CJ38 (Machine signal output) Digital output 32 points (1st station) (10) CJ40 (Machine signal output)
  • Page 131 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications CJ38 CJ40 CJ42 O Y200 O Y210 O Y220 O Y230 O Y260 O Y270 O Y201 O Y211 O Y221 O Y231 O Y261 O Y271 O Y202 O Y212 O Y222 O Y232 O Y262...
  • Page 132 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal output circuit Use within the specification ranges shown below. Output circuit [FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761] Source output CG32/CG36/CJ38/CJ40/CJ42 DOCOM Stabilized Control power supply circuit 24VDC(+) Load...
  • Page 133 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (Note 2) When the rush current exceeds the maximum output current, always connect a protective resistor (R=150Ω) serially to the load to suppress rush currents. Make sure that the current is less than the maximum output current including the momentary current.
  • Page 134 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (7) CJ37 (Machine signal input) Digital input 48 points (1st and 2nd stations) (9) CJ39 (Machine signal input) Digital input 48 points (2nd and 3rd stations) CJ37 CJ39 X200 X218 X230 X248 X201 X219...
  • Page 135 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal input circuit Both 24V common and 0V common connections are allowed in the digital signal input circuit. Follow the wiring diagram below for each type. Input circuit 24V common 0V common CJ37/CJ39...
  • Page 136 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (12) MPG (Manual pulse generator input) 5V manual pulse generator and 12V manual pulse generator can be connected to this connector. [FCU8-DX731] HA2A HA2B HA1A HA1B +12V +12V [FCU8-DX750 / FCU8-DX760 / FCU8-DX761] HA3A HA3B HA2A...
  • Page 137 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications <Specification of input part> 5V manual pulse generator 12V manual pulse generator Two phases (A phase, B phase, a phase difference 90 degrees) Number of pulse phases (Refer to the waveform below.) Signal output of manual pulse Open collector output generator...
  • Page 138 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications <Input/output circuit> (a) 5V manual pulse generator 470Ω HA1A HA2A HA3A 470Ω Control circuit HA1B HA2B HA3B (Note) No HA3A and HA3B in FCU8-DX731. (b) 12V manual pulse generator 470Ω HA1A HA2A HA3A 470Ω...
  • Page 139 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (13) RIO3EXT (Remote I/O 2.0 communication) (14) RIO3 (Remote I/O 2.0 communication) 1 2 3 TXRXD TXRXD* <Cable side connector type> Connector : 1-1318119-3 Contact : 1318107-1 x6 Recommended manufacturer : Tyco Electronics Refer to the following chart for the maximum number of connecting stations and I/O points.
  • Page 140 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (16) NCKB (Keyboard I/F) (17) AO (Analog output) Analog output can be connected to this connector. - Connect connector case with FG pattern. <Cable side connector type> Plug : 10120-3000PE Shell : 10320-56F0-008 Recommended manufacturer : 3M (Note) When using the jackscrew M2.6-type 10320-56S0-008-F for the shell, do not fasten the screws...
  • Page 141 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (18) AIO (Analog input, Analog output) Analog input and analog output can be connected to this connector. - Connect connector case with FG pattern. <Cable side connector type> Plug : 10120-3000PE Shell : 10320-56F0-008 Recommended manufacturer : 3M (Note)
  • Page 142 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of analog signal input circuit Input circuit Input conditions Analog input voltage -10 to 10V Max. input rating (Note 1) ±15V Resolution |-10 ~ +10V| / 4095 = 4.88mV Precision Within ±25mV (Note 2) Tolerance...
  • Page 143 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (19) OPKB (Scan input, Scan output) OPKB LC3B LC3A LC2B LC2A LC1B LC1A LC0B LC0A LD7B* LD7A* LD6B* LD6A* LD5B* LD5A* LD4B* LD4A* LD3B* LD3A* LD2B* LD2A* LD1B* LD1A* LD0B* LD0A* KYC7* KYC6* KYC5*...
  • Page 144 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of scan input circuit Input circuit OPKB KYC0* KYC1* KYC2* Control circuit KYD0* KYD1* KYD2* Input conditions Number of points 64 points Configuration Matrix of 8 common signals × 8 data signals Rated voltage 5 VDC Minimum applicable load...
  • Page 145 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (b) Outline of scan output circuit Output circuit OPKB LC0A LC1A LC2A Control circuit 100Ω LD0A* LD1A* LD2A* Output conditions Number of points 64 points Matrix of 4 common signals × 4 data signals + Configuration 4 common signals ×...
  • Page 146 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (20) DCIN (24VDC input) +24V <Cable side connector type> Connector : 2-178288-3 Contact : 1-175218-5 Recommended manufacturer : Tyco Electronics (a) Specifications of power supply Consider the following characteristics when selecting the stabilized power supply (prepared by machine tool builder).
  • Page 147 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] FCU8-DX731 FCU8-DX750 FCU8-DX760 (12) (13) (10) (10) (11) FCU8-DX761 FCU8-DX834 (10) (10) (11) (11) Status Name Function Color Details Normal At fault FUSE Fuse status Green Not lit Not lit when a fuse has been blown out. Energization status of 24VDC input DOCOM (DOCOM) of CG32/CG36/CJ38/CJ40...
  • Page 148: Remote I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.12 Remote I/O Unit Types of signals described on the list of units can be input/output from the remote I/O unit (FCU8-DXxxx) according to the type and No. of contacts. Remote I/O units are used by being connected to the control unit or the operation panel I/O unit.
  • Page 149: Fcu8-Dx220 / Fcu8-Dx230 / Fcu8-Dx231 / Fcu8-Dx202 / Fcu8-Dx213 / Fcu8-Dx213-1 / Fcu8-Dx654 / Fcu8-Dx654-1 / Fcu8-Dx651/ Fcu8-Dx408 / Fcu8-Dx409

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.12.2 FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX202 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1 / FCU8-DX651/ FCU8-DX408 / FCU8-DX409 [Outline dimension : FCU8-DX220] [mm] (Space required for wiring) [Outline dimension : FCU8-DX230] [mm] (Space required for...
  • Page 150 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX231] [mm] (Space required for wiring) [Outline dimension : FCU8-DX202] [mm] (Space required for wiring) IB-1501269-J...
  • Page 151 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX213] [mm] (Space required for wiring) [Outline dimension : FCU8-DX213-1] [mm] (Space required for wiring) IB-1501269-J...
  • Page 152 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX654] [mm] (Space required for wiring) [Outline dimension : FCU8-DX654-1] [mm] (Space required for wiring) IB-1501269-J...
  • Page 153 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX651] [mm] (Space required for wiring) [Outline dimension : FCU8-DX408] [mm] (Space required for wiring) IB-1501269-J...
  • Page 154 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-DX409] [mm] (Space required for wiring) IB-1501269-J...
  • Page 155 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Installation dimension : FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX202 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1 / FCU8-DX408 / FCU8-DX409] [mm] (Unit outline) 2-M5 Screw [Installation dimension : FCU8-DX651] [mm] 3-M5 Screw 88 ±...
  • Page 156 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] FCU8-DX220 FCU8-DX230 / DX231 FCU8-DX202 FCU8-DX213 / DX213-1 FCU8-DX654 / DX654-1 (s1) (s2) (s1) (s1) (s1) (s1) (13) (s2) (s2) (s2) (s2) (14) (13) (13) (13) (13) (19) (14) (14) (14) (14) (15)
  • Page 157 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc. Connect the cables to the designated connectors. Incorrect connections could damage the device. 12V, 5V, and 3.3V output from connectors are to supply the power for dedicated peripheral devices.
  • Page 158 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal input circuit Both 24V common and 0V common connections are allowed in the digital signal input circuit. Follow the wiring diagram below for each type. Input circuit 24V common 0V common CJ31/CJ33...
  • Page 159 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (2) CJ32 (Machine signal output) (4) CJ34 (Machine signal output) CJ32 CJ34(FCU8-DX230) CJ34(FCU8-DX231) O Y00 O Y10 O Y20 O Y20 O Y01 O Y11 O Y21 O Y21 O Y02 O Y12 O Y22 O Y22...
  • Page 160 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal output circuit Use within the specification ranges shown below. Output circuit Source output 24VDC Control circuit CJ32/CJ34 Load Output conditions Insulation method Non-insulation Rated load voltage 24VDC 0.2A/point Max.
  • Page 161 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (Note 2) When the rush current exceeds the maximum output current, always connect a protective resistor (R=150Ω) serially to the load to suppress rush currents. Make sure that the current is less than the maximum output current including the momentary current.
  • Page 162 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (b) Outline of analog signal output circuit The analog signal output circuit can be used only for FCU8-DX231. Output circuit CJ34 Load 500Ω Output conditions Analog output voltage -10 to 10V(±5%) Resolution 10V / 4095 = 2.44mV Load conditions...
  • Page 163 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (5) CJ35 (Machine signal input) COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ <Cable side connector type> Connector : 713-1116/037-000 Recommended manufacturer : WAGO (The cable side connector is attached to the unit.) IB-1501269-J...
  • Page 164 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal input circuit Follow the wiring diagram below. Input circuit 0V common CJ35 External contact Input resistance Control COMA+ circuit External contact Input resistance COMB+ CJ36 Stabilized power supply IO24VA 24VDC(+)
  • Page 165 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (6) CJ36 (Machine signal output) IO24VB IO0VB IO24VA IO0VA COMB- COMA- COMB- COMA- COMB- COMA- COMB- COMA- <Cable side connector type> Connector : 713-1110/037-000 Recommended manufacturer : WAGO (The cable side connector is attached to the unit.) (a) Outline of digital signal output circuit Use within the specification ranges shown below.
  • Page 166 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Output conditions Insulation method Photo coupler insulation Rated load voltage 24VDC 2A/point Max. output current 8A or less in the whole unit Output delay time 400μs (Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance 100V or more, twice or more the load current) in parallel to the load.
  • Page 167 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (7) SDI (Safety machine signal input) SX07B COMB+ SX07A COMA+ SX06B COMB+ SX06A COMA+ SX05B COMB+ SX05A COMA+ SX04B COMB+ SX04A COMA+ SX03B COMB+ SX03A COMA+ SX02B COMB+ SX02A COMA+ SX01B COMB+ SX01A COMA+...
  • Page 168 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal input circuit Follow the wiring diagram below. Input circuit 0V common External duplication contact SX0A Input resistance Control circuit SX3A SX0B Input resistance SX3B Control COMA+ circuit COMB+ Stabilized...
  • Page 169 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (8) SDO (Safety machine signal output) IO24VB IO0VB IO24VA IO0VA SY03B COMB- SY03A COMA- SY02B COMB- SY02A COMA- SY01B COMB- SY01A COMA- SY00B COMB- SY00A COMA- <Cable side connector type> Connector : 713-1110/037-000 Recommended manufacturer : WAGO (The cable side connector is attached to the unit.) (a) Outline of digital signal output circuit...
  • Page 170 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Output conditions Insulation method Photo coupler insulation Rated load voltage 24VDC 2A/point Max. output current 8A or less in the whole unit Output delay time 400μs (Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance 100V or more, twice or more the load current) in parallel to the load.
  • Page 171 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (9) SDI1 (Safety DI input) COM+ SX04B   COM+ SX04A   COM+ SX03B   COM+ SX03A   COM+ SX02B   COM+ SX02A   COM+ SX01B   COM+ SX01A   COM+ SX00B  ...
  • Page 172 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal input circuit Follow the wiring diagram below. Input circuit External duplication contact SDI1 / SDI2 SX00A 5kΩ Control circuit SX07A SX00B 5kΩ 24VDC SX07B COM+ Control circuit COM+ DCIN...
  • Page 173 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (10) SDI2 (Safety DI input) COM+ SX07B   COM+ SX07A   COM+ SX06B   COM+ SX06A   COM+ SX05B   COM+ SX05A   <Cable side connector type> Connector : 175362-1 (2-pole type) Connector : 175363-1 (4-pole type) Connector : 1318095-1 (6-pole type) Contact : 175218-2...
  • Page 174 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of digital signal output circuit Use within the specification ranges shown below. Output circuit SDO1 24VDC SYR00A Load Control circuit SYR03A SYR00A SYR03A SDO2 Control circuit SYR00B Load SYR03B Relay feedback SYR00B Welding check LED...
  • Page 175 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Precautions (1) Influence on the relay life by a connected load An actual relay life can be substantially shortened depending on the type of a connected load and the characteristics of its inrush current. The inrush current generated by a connected load can lead to contact welding of the module.
  • Page 176 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (2) Measures against back EMF Provide a contact protection circuit for an extended contact life, noise prevention at contact close, and reduction of the carbides and nitric acids formed by an arc discharge. An incorrect circuit involves a high risk of contact welding.
  • Page 177 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (13) RIO1 (Remote I/O 2.0 communication) (14) RIO2 (Remote I/O 2.0 communication) 1 2 3 TXRXD TXRXD* <Cable side connector type> Connector : 1-1318119-3 Contact : 1318107-1 x6 Recommended manufacturer : Tyco Electronics (15) DCIN (24VDC input) +24V <Cable side connector type>...
  • Page 178 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (17) FG (FG terminal) (18) FG (FG terminal (M4 screw)) (19) AIO1 (Analog input, Analog output) Analog input and analog output can be connected to this connector. AI 0 AI 1 AI 2 AI 3 - Connect connector case with FG pattern.
  • Page 179 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a) Outline of analog signal input circuit Input circuit AIO1 Input conditions Analog input voltage -10 to 10V Max. input rating (Note 1) ±15V Resolution |-10 to +10V| / 4095 = 4.88mV Precision Within ±25mV (Note 2) Tolerance...
  • Page 180 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (20) THERMISTOR (Thermistor input) Thermistor can be connected to this connector. CH10 CH11 CH12 Thermistor CH1 Thermistor CH2 Thermistor CH3 Thermistor CH4 Thermistor CH5 Thermistor CH6 Thermistor CH1 Thermistor CH2 Thermistor CH3 Thermistor CH4 Thermistor CH5 Thermistor CH6...
  • Page 181 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (21) AI (Multi-analog input) V+/A V+/A l+/a/CJ+ l+/a/CJ+ V-/l-/B V-/l-/B b/CJ- b/CJ- V+/A V+/A l+/a/CJ+ l+/a/CJ+ V-/l-/B V-/l-/B b/CJ- b/CJ- <Cable side connector type> Connector : DFMC1,5/12-ST-3,5-LR Recommended manufacturer : Phoenix Contact (The cable side connector is attached to the unit.) (a) Outline of multi-analog input circuit There are four types of multi-analog input as below:...
  • Page 182 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a-1) Outline of voltage input circuit Input circuit FCU8-DX409 Voltage source Input conditions Set the input signal within the range as shown in the conditions below. Input voltage range -10V to +10V Max.
  • Page 183 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a-3) Outline of thermocouple input circuit Input circuit FCU8-DX409 Thermocouple Constant current source Cold junction compensation resistor (Pt100) Set the lead length 2cm or shorter. (As a guide) Input conditions Set the input signal within the range as shown in the conditions below. Input temperature range -40°C to +600°C Resolution...
  • Page 184 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a-4) Outline of resistance temperature detector input circuit Input circuit FCU8-DX409 <3-wire type> Constant current source Resistance temperature detector <4-wire type> FCU8-DX409 Constant current source Resistance temperature detector Input conditions Set the input signal within the range as shown in the conditions below. Input temperature range -50°C to +300°C Resolution...
  • Page 185 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (a-5) Supplement: Overall precision of temperature measurement The precision shown in (a-3) and (a-4) is the one attributed to the unit. The thermocouple or resistance temperature detector input to the unit also has precision and the overall precision of temperature measurement is the addition of the precision of unit and the precision of thermocouple or resistance temperature detector.
  • Page 186 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (s1) STATION No. (Station No. group setting switch) (s2) STATION No. (Station No. setting switch) (s3) STATION No. (Station No. setting switch) IB-1501269-J...
  • Page 187 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED : FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX202 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1 / FCU8-DX408 / FCU8-DX409] FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX202 FCU8-DX408 FCU8-DX409...
  • Page 188 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED : FCU8-DX651] Status Name Function Color Details Normal At fault Safety relay output SYR00 status Green Not lit Not lit when a relay has been blown out. Safety relay output SYR01 status Green Not lit Not lit when a relay has been blown out.
  • Page 189: Function Expansion Unit

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.13 Function Expansion Unit 4.13.1 Functional Safety Expansion Unit (FCU8-EX133) [Outline dimension] [mm] 118.2 23.4 IB-1501269-J...
  • Page 190: Communication Expansion Unit

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14 Communication Expansion Unit 4.14.1 CC-Link (FCU8-EX561) [Outline dimension] [mm] 94.6 IB-1501269-J...
  • Page 191 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Connector Function name CC-Link communication CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc. Connect the cables to the designated connectors.
  • Page 192 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Color Status Details CC-Link module in the normal state (1) RUN Green Not lit Watchdog timer error (2) LRUN Green Data link in process of execution (3) SD Green During data transmission (4) RD Green...
  • Page 193: Profibus-Dp (Fcu8-Ex563)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14.2 PROFIBUS-DP (FCU8-EX563) [Outline dimension] [mm] 94.6 IB-1501269-J...
  • Page 194 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Connector Function name PROFIBUS-DP CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc. Connect the cables to the designated connectors. Incorrect connections could damage the device. 5V output from connectors are to supply the power for dedicated peripheral devices.
  • Page 195 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Color Status Details Green Lit when PROFIBUS-DP module is normally operated Green/ (1) RUN (Green) Flashing Boot standby yellow (2) RDY (Yellow) (Module status) Yellow Boot error No power supply, module failure Configuration successful, communication Green Lit regularly...
  • Page 196: Cc-Link Ie Field (Fcu8-Ex564)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14.3 CC-Link IE Field (FCU8-EX564) [Outline dimension] [mm] 94.6 IB-1501269-J...
  • Page 197 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Connector name Function LAN1 CC-Link IE Field communication LAN2 CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc. Connect the cables to the designated connectors.
  • Page 198 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Color Status Details Not lit Normal data received and loopback not performed L ERR Abnormal data received or loopback being performed Data being sent or received SD/RD Green Not lit Data not sent nor received Data link (cyclic transmission being performed) D LINK...
  • Page 199: Ethernet/Ip (Fcu8-Ex565)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14.4 EtherNet/IP (FCU8-EX565) [Outline dimension] [mm] 94.6 IB-1501269-J...
  • Page 200 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Connector Function name LAN1 EtherNet/IP communication (Note) On this unit, EtherNet/IP function is supported by the "LAN1" port only. LAN2 does not support EtherNet/ IP function. CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc.
  • Page 201 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] Name Green LED Red LED Details (1) MS (Green/Red) Flashing Flashing In self-test (Module status) Flashing Not lit Waiting for initialization Not lit Normal operation Not lit Flashing Recoverable failure Unrecoverable failure (The hardware needs to be Not lit replaced.)
  • Page 202: Fl-Net (Fcu8-Ex568)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14.5 FL-net (FCU8-EX568) [Outline dimension] [mm] 94.6 IB-1501269-J...
  • Page 203 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Connector Function name LAN1 FL-net communication (Note) On this unit, FL-net function is supported by the "LAN1" port only. LAN2 does not support FL-net function. CAUTION Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this could cause bursting, damage, etc.
  • Page 204 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [LED] (1) Ignore LED of FCU8-EX568. (This is used by MITSUBISHI.) IB-1501269-J...
  • Page 205: Option Relay Unit (Fcu8-Ex702)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14.6 Option Relay Unit (FCU8-EX702) [Outline dimension] [mm] 94.6 IB-1501269-J...
  • Page 206: Option Relay Unit (Fcu8-Ex703)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.14.7 Option Relay Unit (FCU8-EX703) [Outline dimension] [mm] 78.4 IB-1501269-J...
  • Page 207: Manual Pulse Generator

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.15 Manual Pulse Generator 4.15.1 5V Manual Pulse Generator (UFO-01-2Z9) 100 pulse/rev [Outline dimension] [mm]     Gasket 3-M4 stud   Index Panel cut diameter 72 at equal pitch 0V A B M3 x 6 8.89 Above size only...
  • Page 208: Manual Pulse Generator (Hd60C)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.15.2 12V Manual Pulse Generator (HD60C) 25 pulse/rev [Outline dimension] [mm] Packing t 2.0 3-M4 stud bolt  L10 Installation of screws other than M3 x 6 not possible 24 0.5 27 0.5 8.89 7.60 [Panel cut dimension]...
  • Page 209: Synchronous Feed Encoder

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.16 Synchronous Feed Encoder 4.16.1 Synchronous Feed Encoder (OSE-1024-3-15-68) [Outline dimension] [mm] Caution plate 5. 4 hole 19. 5 14. 3 - 0.11 - 0.006 - 0. 012 - 0.017 - 0. 042 + 0.14 + 0.14 1.
  • Page 210 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Connector pin assignment Function Function A phase Z phase B phase A phase reverse Case grounding Z phase reverse B phase reverse IB-1501269-J...
  • Page 211: Mitsubishi Cnc Machine Operation Panel

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.17 MITSUBISHI CNC Machine Operation Panel 4.17.1 Main Panel A , B (FCU8-KB921 / FCU8-KB922 / FCU8-KB925 , FCU8-KB923 / FCU8-KB924 / FCU8-KB926) [Outline dimension : FCU8-KB921] [mm] (Space required for wiring)
  • Page 212 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Outline dimension : FCU8-KB923] [mm] (Space required for wiring) [Outline dimension : FCU8-KB924] [mm] (Space required for wiring) [Outline dimension : FCU8-KB926] [mm] (Space required for wiring) IB-1501269-J...
  • Page 213 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Panel cut dimension : FCU8-KB921 / FCU8-KB922 / FCU8-KB925] [mm] (Unit outline) 248±0.3 4-M3 screw 246±0.3 1±0.2 (6.5) (6.5) (Square hole dimension) [Panel cut dimension : FCU8-KB923 / FCU8-KB924 / FCU8-KB926] [mm] (Unit outline) 278±0.3...
  • Page 214 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] FCU8-KB921 / (2) (3) (4) FCU8-KB922 / FCU8-KB925 FCU8-KB923 / (2) (3) (4) FCU8-KB924 / FCU8-KB926 Connector Connector Function Function name name Remote I/O 2.0 communication DCIN 24VDC input RIOOUT (relay) DCOUT 24VDC output...
  • Page 215 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (1) DCIN (24VDC input) +24V <Cable side connector type> Connector : 2-178288-3 Contact : 1-175218-5 Recommended manufacturer : Tyco Electronics (2) DCOUT (24VDC output) +24V <Cable side connector type> Connector : 2-178288-3 Contact : 1-175218-5 Recommended manufacturer : Tyco Electronics (3) RIOIN (Remote I/O 2.0 communication (input))
  • Page 216 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (6) SUBP (Sub panel connection) Spare SW(ZR5423[5]) Spare SW(ZR5423[4]) Spare SW(ZR5423[3]) Memory protection (ZR5423[2]) RSW3_G(ZR5423[1]) RSW3_F(ZR5422[D]) RSW3_E(ZR5422[F]) RSW3_D(0V) RSW3_C(ZR5423[0]) RSW3_B(ZR5422[E]) RSW3_A(ZR5422[C]) RSW2_G(ZR5422[B]) RSW2_F(ZR5422[7]) RSW2_E(ZR5422[9]) RSW2_D(0V) RSW2_C(ZR5422[A]) RSW2_B(ZR5422[8]) RSW2_A(ZR5422[6]) RSW1_G(ZR5422[5]) RSW1_F(ZR5422[1]) RSW1_E(ZR5422[3]) RSW1_D(0V) RSW1_C(ZR5422[4]) RSW1_B(ZR5422[2])
  • Page 217: Sub Panel A (Fcu8-Kb931 / Fcu8-Kb941)

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.17.2 Sub Panel A (FCU8-KB931 / FCU8-KB941) [Outline dimension : FCU8-KB931] [mm] (Space required for wiring) [Outline dimension : FCU8-KB941] [mm] (Space required for wiring) [Panel cut dimension : FCU8-KB931 / FCU8-KB941] [mm] (Unit outline) 128±0.3...
  • Page 218 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications [Connector] Switch name Switch name Rapid traverse override ON switch Emergency stop switch OFF switch Memory protection switch Cutting override (1) Rapid traverse override Output signal a Output signal c Output signal e Common terminal Output signal d Output signal b...
  • Page 219 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (2) Emergency stop switch Contact 1 (B contact) Contact 2 (B contact) <Switch type> Switch : XA1E-BV4U02TR Recommended manufacturer : IDEC Connection : Terminal <Cable side connector type> Connector: Faston terminal #110 Recommended manufacturer : - (3) Memory protection switch Contact 2 Contact 1...
  • Page 220 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (4) ON switch Switch NC NO Lamp terminal (+) Lamp terminal (-) Contact 1 (A contact) Contact 2 (B contact) (Note) Connect LGCON terminal and ON terminal of G170 cable to NO terminal of ON switch. <Switch type>...
  • Page 221 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications (6) Cutting override Output signal a Output signal c Output signal e Common terminal Output signal d Output signal b Parity check signal <Switch type> Switch : AC09-GY0/20L3B02 Recommended manufacturer : Fuji Electric Connection : Connector <Switch side connector type>...
  • Page 222: Handy Terminal

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.18 Handy Terminal Unit name Handy terminal Item Type HG1T-SB12UH-MK1346-L5 Ambient During 0 to 40 ℃ temperature operation During -20 to 60 ℃ storage Long term: 10 to 75% RH (with no dew condensation) Ambient humidity General...
  • Page 223 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Dimension and names of parts 46.7 (10) (11) 11.5 Name Function/ Specification Name Function/ Specification Monochrome display with Host interface connector backlight HOST (DDK: 17JE-23250-02(D8A6)) 192(W) × 64(H) dots Emergency stop switch Contact rating/ Contact: 24VDC, Host interface cable Contact configuration: 2b contacts...
  • Page 224 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Signal explanation HOST HOST connector Input/ Function/ Name terminal No. signal name Output Frame ground Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Ground RS(RTS) RS-232C communication signal (Request To Send) CS(CTS) RS-232C communication signal (Clear To Send) SW2_C11...
  • Page 225 M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications Terminal connections Handy terminal side 24VDC(+) Insulation type DC-DC 24VDC input 24VDC(-) converter SW2_C11 SW2_C12 Enable switch SW2_C21 SW2_C22 SW1_NC11 SW1_NC12 Emergency stop switch SW1_NC21 SW1_NC22 SW6_NO1 Switchover switch SW6_C1 IB-1501269-J...
  • Page 226: Thermistor

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.19 Thermistor 4.19.1 Thermistor(PT3C-51F-M2) [Outline dimension] [mm] 250±10 Made by SHIBAURA ELECTRONICS Co., Ltd. Ambient temperature -10 to + 190 ℃ Insulation resistance 100MΩ or more at 500VDC [between case and lead wire] IB-1501269-J...
  • Page 227: Exclusive Sd Cards For Mitsubishi Cnc

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.20 Exclusive SD Cards for MITSUBISHI CNC Item FCU8-SD001G FCU8-SD004G Capacity NAND Flash SLC (Note 1) During operation -25 ℃ to +85 ℃ Ambient temperature During storage -40 ℃ to +85 ℃...
  • Page 228: Specifications And Precautions Of Usb/Sd/Lan Interface

    M800S/M80/E80 Series Connection and Setup Manual 4 General Specifications 4.21 Specifications and Precautions of USB/SD/LAN Interface 4.21.1 USB Interface (Memory I/F card) M800S / M80 Standards USB2.0 High Speed (480Mbps) Data transfer speed Full Speed (12Mbps) (Note) Low Speed (1.5Mbps) Power supply to USB Supply voltage: 5V ±...
  • Page 229: Sd Interface (Memory I/F Card)

    SD card (requires converting adapter). In case of using one of them, careful performance check must be required by the machine tool builder. Commercially available devices may not be compatible with MITSUBISHI units or suitable FA environment for temperature- or noise-wise.
  • Page 230: Installation

    Installation IB-1501269-J...
  • Page 231: Heat Radiation Countermeasures

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.1 Heat Radiation Countermeasures Please refer to the following method for heat radiation countermeasures. Example of heat radiation countermeasures <Hypothetical conditions> (1) Average internal temperature of operation panel: T ≤ 58°C (2) Peripheral temperature of operation panel : Ta ≤ 0°C to 45°C (3) Internal temperature rise value : ΔT = T - Ta (max) = 13°C Procedures for heat design and verification Calculate total heat radiation of each...
  • Page 232 M800S/M80/E80 Series Connection and Setup Manual 5 Installation The following shows an example of calculation applied to heat radiation countermeasures for the operation panel when 15-type display unit is used. Because heat will accumulate in the upper portions of the unit, install an agitating fan as required.
  • Page 233 M800S/M80/E80 Series Connection and Setup Manual 5 Installation Calculation example of panel internal heating value (1) Calculation of unit heating value (In the case of FCU8-DU181-32 + FCU8-KB083 + FCU8-DX750) Heating value (W) Total heating value of units (W) : 16.6W (= display unit + operation panel I/O unit) Total heating value (W) by machine input (D1) : 5.5W (= 24V (total heating value when the 48 points are simultaneously turned ON) ×...
  • Page 234: Noise Countermeasures

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.2 Noise Countermeasures 5.2.1 Connection of Frame Ground (FG) The frame should basically be grounded at one ground point. Connect the control unit and operation panel I/O unit's 0V (RG) to the FG on the +24V stabilized power supply. Operation panel I/O unit Control unit J070 cable...
  • Page 235: Shield Clamping Of Cables

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.2.2 Shield Clamping of Cables The shield of the shield cable connected to the control unit and drive unit must be connected to the grounding plate to stabilize operation while preventing malfunctioning due to noise. The shield can be connected to the grounding plate with lead wires or clamp fittings.
  • Page 236: Connecting Spark Killers

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.2.3 Connecting Spark Killers The noise which is generated during the operation of the coil or contact needs to be eliminated. Connect the spark killers (CR composite element) in the parallel with the coil and the contact for the countermeasure. The Spark killer is effective in eliminating the noise generated by electromagnetic induction.
  • Page 237: Lightning Surge Protection Countermeasure

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.2.4 Lightning Surge Protection Countermeasure Generally, the lightning surge intrudes into the control power supply of device from the power supply line, and the surge may damage the control power supply and the internal circuit. For protection from the lightning surge, MITSUBUSHI NC unit has the surge absorber for the control power supply of the NC control section and the NC drive section.
  • Page 238: Unit Installation

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3 Unit Installation 5.3.1 Display Unit Mount the display unit with the prescribed number of fixing screws. (Note) Refer to "General Specifications: Display Unit" for the panel cut dimension drawing and the screw hole position.
  • Page 239 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-DU141 (10.4-type display unit)] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (4 pcs). (4 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 240 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-DU181 (15-type display unit)] - Fixed on the front side Fixing screw: Cheese head screw M3 (8 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (8 pcs). (8 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 241: Keyboard Unit

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3.2 Keyboard Unit Mount the keyboard unit with the prescribed number of fixing screws. (Note) Refer to "General Specifications: Keyboard Unit" for the panel cut dimension drawing and the screw hole position. [FCU8-KB024/KB025/KB026/KB028] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs).
  • Page 242 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-KB029] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (4 pcs). (4 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 243 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-KB041/KB046] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (4 pcs). (4 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 244 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-KB047] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (4 pcs). (4 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 245 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-KB048] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (4 pcs). (4 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 246 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-KB083] - Fixed on the front side Fixing screw: Cheese head screw M3 (6 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (6 pcs). (6 pcs of screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 247: Operation Panel I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3.3 Operation Panel I/O Unit Mount the operation panel I/O unit with the prescribed number of fixing screws. (Note) Refer to "General Specifications: Operation Panel I/O Unit" for the installation dimension and the screw hole position.
  • Page 248: Remote I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3.4 Remote I/O Unit Mount the remote I/O unit with the prescribed number of fixing screws. (Note) Refer to "General Specifications: Remote I/O Unit" for the installation dimension and the screw hole position. [FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX202 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1 / FCU8-DX408 / FCU8-DX409] Fixing screw: M5 (2pcs)
  • Page 249 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [Install to DIN rail] (1) Set down the rail hook. (2) Hook the upper latch of the unit on the DIN rail. (3) Push the unit into the rail. (4) Lock it. Designate the type below as DIN rail standard - TH35-7.5Fe : 7.5 - TH35-7.5AL : 7.5...
  • Page 250: Functional Safety Expansion Unit

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3.5 Functional Safety Expansion Unit Install the functional safety expansion unit as follows: (1) Open the cover of control unit. (2) Fix the functional safety expansion unit with 2 screws. (3) Close the cover of control unit. IB-1501269-J...
  • Page 251: Communication Expansion Unit

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3.6 Communication Expansion Unit Install the expansion unit as follows: [FCU8-EX702] (1) Remove the cover on the back side of control unit. (2) Insert FCU8-EX561/EX563/EX564/EX565/EX568 into FCU8-EX702. (3) Fix FCU8-EX702 to the control unit with three screws of M3 x 25. IB-1501269-J...
  • Page 252 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-EX703] (1) Remove the cover of FCU8-EX703. (2) Insert FCU8-EX561/EX563/EX564/EX565/EX568 into FCU8-EX703. (3) Close the cover of FCU8-EX703. (4) Remove the cover on the back side of control unit. (5) Fix FCU8-EX703 to the control unit with three screws of M3 x 25. IB-1501269-J...
  • Page 253: Mitsubishi Cnc Machine Operation Panel

    M800S/M80/E80 Series Connection and Setup Manual 5 Installation 5.3.7 MITSUBISHI CNC Machine Operation Panel Mount the MITSUBISHI CNC machine operation panel (main panel and sub panel) with the prescribed number of fixing screws. (Note) Refer to "General Specifications: MITSUBISHI CNC Machine Operation Panel" for the panel cut dimension drawing and the screw hole position.
  • Page 254 M800S/M80/E80 Series Connection and Setup Manual 5 Installation [FCU8-KB931/FCU8-KB941] - Fixed on the front side Fixing screw: Cheese head screw M3 (4 pcs). (Fixing screws are provided with the unit.) - Fixed on the back side Fixture: M3 nut (4 pcs). (4 pcs of the screw caps (a) are provided with the unit.) IB-1501269-J...
  • Page 255 M800S/M80/E80 Series Connection and Setup Manual 5 Installation IB-1501269-J...
  • Page 256: Precautions For Connecting

    Precautions for Connecting IB-1501269-J...
  • Page 257: Precautions For Wiring

    M800S/M80/E80 Series Connection and Setup Manual 6 Precautions for Connecting 6.1 Precautions for Wiring 6.1.1 Precautions when Connecting/Disconnecting Cables If the cable is connected/disconnected without turning the power OFF, the normal unit or peripheral devices could be damaged, and risks could be imposed. Disconnect each cable with the following procedures.
  • Page 258 M800S/M80/E80 Series Connection and Setup Manual 6 Precautions for Connecting (b) For a flat cable type connector with latches, open the latches in the directions of the arrows, and pull the connector off. Open Pull For a flat cable type connector without latches, hold the connector with a thumb and forefinger, and pull the connector off.
  • Page 259 M800S/M80/E80 Series Connection and Setup Manual 6 Precautions for Connecting (e) For the optical cable connector, pull off while holding down the lock button. Press Pull For the Ethernet connector, pull off while holding down the locked latch. (1) Press Pull (g) For the USB connector, pull off while holding down the locked latch.
  • Page 260: Precautions For Using Optical Communication Cable

    Special precautions, differing from the conventional cable, are required when laying and handling the optical communication cable. (Note) If the cable you use is not Mitsubishi's, malfunctions resulted from connection problems or aged deterioration are not covered under the warranty. Optical communication cable outline and parts...
  • Page 261: Precautions For Connecting 24V Power Supply

    M800S/M80/E80 Series Connection and Setup Manual 6 Precautions for Connecting Precautions for laying optical communication cable (1) Do not apply a force exceeding the cable's tolerable tension. Binding the cables too tight with tie-wraps could result in an increased loss or a disconnection. Use a cushioning material such as a sponge or rubber when bundling the cables and fix so that the cables do not move.
  • Page 262: Turning The Power On/Off

    M800S/M80/E80 Series Connection and Setup Manual 6 Precautions for Connecting 6.2 Turning the Power ON/OFF The diagram below shows the ON/OFF timing of the drive unit power supply (200VAC/400VAC), remote I/O unit power supply (24VDC) and control unit power supply (24VDC). [Power ON] Turn the power ON in the following order;...
  • Page 263 M800S/M80/E80 Series Connection and Setup Manual 6 Precautions for Connecting IB-1501269-J...
  • Page 264: Connection Of Control Unit

    Connection of Control Unit IB-1501269-J...
  • Page 265: Control Unit Connection System Drawing

    "General specifications: Control Unit [M800S]" "General specifications: Control Unit [M80]" "General specifications: Control Unit [E80]" (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel". IB-1501269-J...
  • Page 266: Connecting With Power Supply

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.2 Connecting with Power Supply Connect a general-purpose 24VDC stabilized power supply to the control unit. J070/J071 DCIN +24V DCIN Control unit (Note 1) Rush current may occur to lead welding on the contacts, when a magnetic switch such as relay directly controls 24VDC's ON/OFF during 24V power supply to the control unit.
  • Page 267: Connecting With Emergency Stop Signal

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.3 Connecting with Emergency Stop Signal Connect the emergency stop switch to EMG connector of the control unit. Emergency stop switch J120 Control unit Emergency stop switch Control unit +24V EMGIN Emergency stop input circuit...
  • Page 268 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit ISO13849-1 (PLd, Cat.3) and IEC62061 (SIL CL2) can be realized by using the safety remote I/O unit (directly wiring the external emergency stop redundantly). Refer to "Smart safety observation" (BNP-C3072-022) for details. <Power supply unit (MDS-E/EH-CV) external emergency stop: Example>...
  • Page 269 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit <Drive unit (MDS-EJ/EJH) external emergency stop: Example> Control unit Stabilized power supply +24V 0V(LG Emergency MDS-EJ/EJH stop switch Control unit J120 +24V EMGIN MDS-EJ/EJH Emergency stop input circuit <Caution> (1) External emergency stop cannot substitute the emergency stop signal which is input to NC.
  • Page 270: Connecting With Operation Panel I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.4 Connecting with Operation Panel I/O Unit Connect the operation panel I/O unit to CJ71 connector of the control unit. [FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761] Control unit Operation panel I/O unit RIO3EXT...
  • Page 271: Connecting With Remote I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.5 Connecting with Remote I/O Unit Connect the remote I/O unit to RIO1 or RIO2 connector of the control unit. Control unit Remote I/O unit Remote I/O 1ch RIO1 J210 Max.64 stations Max.
  • Page 272: Connecting With Drive Unit

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.6 Connecting with Drive Unit Connect the optical communication cables from the NC to the each drive unit so that they run in a straight line from the NC to the drive unit that is a final axis. Note that the number of connected axes is limited by the NC. (Note) Refer to "Precautions for Using Optical Communication Cable"...
  • Page 273: Connecting With Drive Unit Mds-E/Eh Series

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.6.1 Connecting with Drive Unit MDS-E/EH Series 7.6.1.1 Connection of Optical Communication Cables CAUTION 1. Connect the NC and the drive units by the optical communication cables. The distance between the NC and the final drive unit must be within 30m and the specified bending radius (for wiring inside panel: 25mm, and for wiring outside panel: 50mm) or more.
  • Page 274 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit (2) When Using Two or More Power Supply Units within a Single NC Communication Bus System Two or more power supply units may be required within a single NC communication bus system if the spindle drive unit capacity is large.
  • Page 275 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit (3) When using the additional axis drive unit by supplying power (L+, L-) from MDS-EM/EMH unit The power (L+, L-) can be supplied to the additional axis drive unit by using the power supply part which is built into MDS-EM/EMH.
  • Page 276: Drive Unit Arrangement

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.6.1.2 Drive Unit Arrangement Arrange the drive units in the following procedure. (1) Install a power supply unit. (2) Arrange drive units in order of the nominal current from largest from the right. (3) In the arrangement, the clearance between the units is 1 mm.
  • Page 277: Connecting With Drive Unit Mds-Em/Emh Series

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.6.2 Connecting with Drive Unit MDS-EM/EMH Series CAUTION Connect the NC and the drive units by the optical communication cables. The distance between the NC and the final drive unit must be within 30m and the specified bending radius (for wiring inside panel: 25mm, and for wiring outside panel: 50mm) or more.
  • Page 278 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit (2) When using the MDS-E/EH unit together The power (L+, L-) can be supplied to the additional axis drive unit by using the power supply part which is built into MDS-EM/EMH.
  • Page 279: Connecting With Drive Unit Mds-Ej/Ejh Series

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.6.3 Connecting with Drive Unit MDS-EJ/EJH Series CAUTION Connect the NC and the drive units by the optical communication cables. The distance between the NC and the final drive unit must be within 30m and the specified bending radius (for wiring inside panel: 25mm, and for wiring outside panel: 50mm) or more.
  • Page 280: Connecting With Pulse-Controlled Inverter [E80]

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.7 Connecting with Pulse-controlled Inverter [E80] Connect the pulse-controlled inverter to RIO1 and RIO2 connectors of the control unit. Control unit RIO2 Cable with shield Pulse-controlled inverter RIO1 Maximum: 30m <Recommended wire material>...
  • Page 281 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit [Connecting the inverter with an FG terminal] Control unit Inverter RIO1 A/PULSE/CW A/PULSE/CW A*/PULSE*/CW* A*/PULSE*/CW* RIO2 B/SIGN/CCW B/SIGN/CCW B*/SIGN*/CCW* B*/SIGN*/CCW* Connect the cable shield to Connect the cable shield to FG of the control unit.
  • Page 282: Connecting With Rs-232C Device

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.8 Connecting with RS-232C Device (1) Connect the RS-232C device to SIO connector of the control unit. Control unit J031 RS-232C device Cable name J030 cable J031 cable <Related items> Cable drawing: "Cable: J030/J031 Cable"...
  • Page 283: Connecting With Skip Signal (Sensor)

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.9 Connecting with Skip Signal (Sensor) Connect the skip signals to SKIP connector of the control unit. Skip signals are used for processing high-speed signals. Always shield the cable. Control unit SKIP J100...
  • Page 284 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit <24V connection at COM terminal> Control unit SKIP J100 2.35kΩ Stabilized power supply 24VDC(+) 1,5,11,15 24V connection at COM terminal (Note 1) NC recognizes input signals of 2ms or more as the valid skip signals. If machine contacts (relay, etc.) are used, malfunctions will occur due to chattering.
  • Page 285: Connecting With Manual Pulse Generator

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.10 Connecting with Manual Pulse Generator Connect the 5V power supply type manual pulse generator (2ch) to ENC connector of the control unit. 5V manual pulse generator (Rear view) NO.1 When connecting one 5V 5V 0V A B...
  • Page 286: Handle Numbers

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.10.1 Handle Numbers There are two types of the handle numbers assignment: automatic assignment and arbitrary assignment. [Automatic assignment] Set all the parameters from "#1395 H1_pno (1st handle selection)" to "#1397 H3_pno (3rd handle selection)" to "0000".
  • Page 287: Connecting With Synchronous Feed Encoder

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.11 Connecting with Synchronous Feed Encoder Connect the synchronous feed encode (1ch) to ENC connector of the control unit. Synchronous feed encoder OSE1024-3-15-68 R054 cable <Right angle> R050 cable <Related items>...
  • Page 288: Connecting I/O Device Via Communication Expansion Unit

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.12 Connecting I/O Device via Communication Expansion Unit Mount the communication expansion unit onto the dedicated slot of the control unit. (Note 1) To use the communication expansion unit, the option relay unit (FCU8-EX70x) is required. (Note 2) When the communication expansion relay unit FCU8-EX703 (for 2 slots) is connected, the available combinations of expansion units are as follows.
  • Page 289: Connecting I/O Device Via Cc-Link

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.12.1 Connecting I/O Device via CC-Link Use the dedicated communication cable for CC-Link network connection. Connect the communication cable to the communication connector of the CC-Link expansion unit. The connector for the communication cable on the CC-Link expansion unit side is provided with the CC-Link expansion unit.
  • Page 290 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit [CC-Link cable connecting procedure] (1) Remove the sheath of the CC-Link cable about 4cm. Shield mesh CC-Link cable (2) Isolate the shield mesh and the wires coverd with shield tape. Remove the shield tape from wires.
  • Page 291 M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit (5) Insert the CC-Link cable into the connector of CC-Link unit. Control unit CC-Link expansion unit Connector of CC-link unit CC-link cable (Note) Connector of CC-Link unit is two-step structure. It is not different even if attach the cable to whichever.
  • Page 292: Connecting I/O Device Via Profibus-Dp

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.12.2 Connecting I/O Device via PROFIBUS-DP The expansion unit FCU8-EX563 functions as a master station of PROFIBUS-DP. Use the PROFIBUS dedicated communication cable for connection to PROFIBUS-DP. Make sure to attach the terminator to the final station unit of the network. There is a slide switch on the PROFIBUS communication cable for setting the terminator.
  • Page 293: Connecting I/O Device Via Cc-Link Ie Field

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.12.3 Connecting I/O Device via CC-Link IE Field The expansion unit FCU8-EX564 functions as a master station or slave (local) station of CC-Link IE Field. Connect the CC-Link IE Field-compatible equipment with an ethernet cable (category 5e or above and twisted pair shield cable). For details, refer to "M800/M80 Series CC-Link IE Field (Master/local) Specifications manual".
  • Page 294: Connecting I/O Device Via Ethernet/Ip

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.12.4 Connecting I/O Device via EtherNet/IP The expansion unit FCU8-EX565 functions as a scanner or an adapter of EtherNet/IP. Connect the EtherNet/IP- compatible equipment with an ethernet cable (category 5e or above and twisted pair shield cable). For details, refer to "M800/M80 Series EtherNet/IP Specifications manual".
  • Page 295: Connecting I/O Device Via Fl-Net

    M800S/M80/E80 Series Connection and Setup Manual 7 Connection of Control Unit 7.12.5 Connecting I/O Device via FL-net The expansion unit FCU8-EX568 functions as a node of FL-net. Connect the FL-net-compatible equipment with an ethernet cable (category 5e or above and twisted pair shield cable). FL-net-compatible equipment Option relay unit (FCU8-EX70x)
  • Page 296: Connection Of Keyboard Unit

    Connection of Keyboard Unit IB-1501269-J...
  • Page 297: Keyboard Unit Connection System Drawing

    M800S/M80/E80 Series Connection and Setup Manual 8 Connection of Keyboard Unit The method for connecting to each unit and device from the keyboard unit is briefly explained in this chapter. 8.1 Keyboard Unit Connection System Drawing Operation panel I/O unit Keyboard unit G402 cable...
  • Page 298: Connection Of Operation Panel I/O Unit

    Connection of Operation Panel I/O Unit IB-1501269-J...
  • Page 299: Operation Panel I/O Unit Connection System Drawing

    J224 cable Analog I/O J070/J071 cable 24VDC Stabilized DCIN power supply J460/J461 cable OPKB Machine control panel, etc. (Note) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel". IB-1501269-J...
  • Page 300: Connecting With Power Supply

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.2 Connecting with Power Supply Connect 24VDC power supply (general-purpose stabilized power supply) to the operation panel I/O unit. 24VDC stabilized power supply DCIN J070/J071 Operation panel +24V I/O unit DCIN...
  • Page 301: Connecting With Frame Ground

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.3 Connecting with Frame Ground [FCU8-DX731] M4 screw Round terminal Frame ground [FCU8-DX750 / FCU8-DX760] M4 screw Round terminal Frame ground IB-1501269-J...
  • Page 302 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit [FCU8-DX761] Round terminal Frame ground M4 screw M4 screw Round terminal Frame ground IB-1501269-J...
  • Page 303: Connecting With Control Unit

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.4 Connecting with Control Unit Connect the control unit to CJ71 connector of the operation panel I/O unit. Control unit Operation panel I/O unit RIO3EXT RIO2.0 Terminator CJ71 J010 connector...
  • Page 304: Connecting With Remote I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.6 Connecting with Remote I/O Unit Connect the remote I/O unit to RIO3EXT connector of the operation panel I/O unit. Control unit RIO occupied stations FCU8-DX731: Operation panel I/O unit 1, 3, 7 to 12, 20 to 22 FCU8-DX750: Remote I/O unit...
  • Page 305: Connecting With Manual Pulse Generator (Mpg)

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.7 Connecting with Manual Pulse Generator (MPG) Connect the manual pulse generator to MPG connector of the operation panel I/O unit. Both 5V power supply type (UFO-01-2Z9) and 12V power supply type (HD60C) manual pulse generator can be used. Take the maximum cable length, etc.
  • Page 306 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit (2) Connecting with 12V manual pulse generator (maximum cable length: 50m) Connect the 12V manual pulse generator to the connector MPG. NO.1 When connecting one 12V manual pulse 12V manual pulse 12V 0V generator...
  • Page 307: Handle Numbers

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.7.1 Handle Numbers There are two types of the handle numbers assignment: automatic assignment and arbitrary assignment. [Automatic assignment] Set all the parameters from "#1395 H1_pno (1st handle selection)" to "#1397 H3_pno (3rd handle selection)" to "0000".
  • Page 308: Connecting With Machine Operation Panel

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8 Connecting with Machine Operation Panel Connect the machine operation panel to CG31/CG32/CG35/CG36/CJ37/CJ38/CJ39/CJ40/CJ42/OPKB connector of the operation panel I/O unit. [FCU8-DX731] Machine operation panel (example) FCU8-DX731 J350 CG31 CG35 J350...
  • Page 309: Wiring For 24V Common Input

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8.1 Wiring for 24V Common Input [FCU8-DX731] Machine side FCU8-DX731 FCU8-DX731 Machine side CG31 CG35 X200 X240 X201 X241 X202 X242 X203 X243 X204 X244 X205 X245 X206 X246 X207...
  • Page 310 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit [FCU8-DX750 / FCU8-DX760 / FCU8-DX761] Machine side Machine side FCU8-DX750/DX760/DX761 FCU8-DX750/DX760/DX761 CJ37 CJ39 X200 X230 X201 X231 X202 X232 X203 X233 X204 X234 X205 X235 X206 X236 X207 X237 X208...
  • Page 311: Wiring For 0V Common Input

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8.2 Wiring for 0V Common Input [FCU8-DX731] Machine side FCU8-DX731 Machine side FCU8-DX731 CG31 CG35 X200 X240 X201 X241 X202 X242 X203 X243 X204 X244 X205 X245 X206 X246 X207...
  • Page 312 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit [FCU8-DX750 / FCU8-DX760 / FCU8-DX761] Machine side Machine side FCU8-DX750/DX760/DX761 FCU8-DX750/DX760/DX761 CJ37 CJ39 X200 X230 X201 X231 X202 X232 X203 X233 X204 X234 X205 X235 X206 X236 X207 X237 X208...
  • Page 313: Wiring For Source Type Output

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8.3 Wiring for Source Type Output [FCU8-DX731] Machine side FCU8-DX731 Machine side FCU8-DX731 CG32 CG36 Y200 Y240 Y201 Y241 Y202 Y242 Y203 Y243 Y204 Y244 Y205 Y245 Y206 Y246 Y207...
  • Page 314 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit [FCU8-DX750 / FCU8-DX760 / FCU8-DX761] Machine side Machine side FCU8-DX750/DX760/DX761 FCU8-DX750/DX760/DX761 CJ38 CJ40 Y200 Y220 Y201 Y221 Y202 Y222 Y203 Y223 Y204 Y224 Y205 Y225 Y206 Y226 Y207 Y227 Y208...
  • Page 315 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit [FCU8-DX834] Machine side FCU8-DX834 Machine side FCU8-DX834 CG32 CG34 Y200 Y220 Y201 Y221 Y202 Y222 Y203 Y223 Y204 Y224 Y205 Y225 Y206 Y226 Y207 Y227 Y208 Y228 Y209 Y229 Y20A...
  • Page 316: Example Of Wiring Cj42 (Fcu8-Dx760)

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8.4 Example of Wiring CJ42 (FCU8-DX760) Machine side FCU8-DX760 CJ42 Y260 Y261 Y262 Y263 Y264 Y265 Y266 Y267 Y268 Y269 Y26A Y26B Y26C Y26D Y26E Y26F DOCOM DOCOM DOCOM DOCOM...
  • Page 317: Connection With The Scan Input Signal (Fcu8-Dx834)

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8.5 Connection with the scan input signal (FCU8-DX834) Machine side FCU8-DX834 OPKB KYC0* X247 X246 X245 X244 X243 X242 X241 X240 KYC1* X24F X24E X24D X24C X24B X24A X249 X248...
  • Page 318: Connection With The Scan Output Signal (Fcu8-Dx834)

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.8.6 Connection with the scan output signal (FCU8-DX834) Machine side FCU8-DX834 OPKB LC0A Y247 Y246 Y245 Y244 Y243 Y242 Y241 Y240 LC1A Y24F Y24E Y24D Y24C Y24B Y24A Y249 Y248...
  • Page 319: Connecting With Analog Output Signal (Fcu8-Dx731)

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.9 Connecting with Analog Output Signal (FCU8-DX731) For the analog output signals, connect J225 cable to the AO connector of FCU8-DX731. The analog output signals are available to connect up to one point for the input, and up to one point for the output. J225 <Related items>...
  • Page 320: Connecting With Analog I/O Signal (Fcu8-Dx761)

    M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit 9.10 Connecting with Analog I/O Signal (FCU8-DX761) For the analog input/output signals, connect J224 cable to the AIO connector of FCU8-DX761. The analog input/output signals are available to connect up to one point for the input, and up to one point for the output. J224 <Related items>...
  • Page 321 M800S/M80/E80 Series Connection and Setup Manual 9 Connection of Operation Panel I/O Unit IB-1501269-J...
  • Page 322: Connection Of Remote I/O Unit

    Connection of Remote I/O Unit IB-1501269-J...
  • Page 323: Remote I/O Unit Connection System Drawing

    (Note 1) The mounted connector differs depending on the unit. Refer to the following chapter for which of the connector is mounted. "General Specifications: Remote I/O unit" (Note 2) For the connection of MITSUBISHI CNC machine operation panel, refer to the chapter "Connection of MITSUBISHI CNC Machine Operation Panel". IB-1501269-J...
  • Page 324: Connecting With Power Supply

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.2 Connecting with Power Supply Connect 24VDC power supply (general-purpose stabilized power supply) to the remote I/O unit. [FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX202 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1 / FCU8-DX408 / FCU8-DX409] Stabilized power supply...
  • Page 325 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [FCU8-DX651] Stabilized power supply 24VDC(+) J070/071 cable DCIN DCOUT G071 cable DCIN <Related items> Cable drawing "Cable : J070/J071 Cable", "Cable : G071 Cable" Connector pin assignment: "General Specifications: Remote I/O Unit" (DCIN connector) IB-1501269-J...
  • Page 326: Connecting With Frame Ground

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.3 Connecting with Frame Ground [FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX202 / FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1 / FCU8-DX408 / FCU8-DX409] Frame ground 250 Series flat terminal <Flat terminal type>...
  • Page 327: Connecting With Control Unit

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.4 Connecting with Control Unit Control unit Remote I/O unit Remote I/O 1ch RIO1 J210 Max.64 stations Max. input: 2048 points Max. output: 2048 points RIO2 Remote I/O  2ch J210 Max.64 stations Max.
  • Page 328: Connecting With Operation Panel I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.5 Connecting with Operation Panel I/O Unit Control unit RIO occupied stations FCU8-DX731: Operation panel I/O unit 1, 3, 7 to 12, 20 to 22 FCU8-DX750: Remote I/O unit 1 to 3, 7 to 12, 20 to 22 FCU8-DX760: 1 to 4, 7 to 12, 20 to 22...
  • Page 329: Connecting With Machine Control Signal (Fcu8-Dx220 / Fcu8-Dx230 / Fcu8-Dx231 / Fcu8-Dx651)

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.6 Connecting with Machine Control Signal (FCU8-DX220 / FCU8-DX230 / FCU8-DX231 / FCU8-DX651) [FCU8-DX220] J351 CJ31 J351 CJ32 <Related items> Cable drawing: "Cable: J351 Cable" Connector pin assignment: "General Specifications: Remote I/O Unit" (CJ31/CJ32 connector) [FCU8-DX230 / FCU8-DX231] J351 CJ31...
  • Page 330 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine input 0V common] Machine side FCU8-DX220/230/231/651 Machine side FCU8-DX230/231 CJ31 CJ33 DICOM DICOM +24V +24V +24V +24V Stabilized Stabilized power supply power supply 24VDC(+) 24VDC(+) DICOM DICOM Stabilized Stabilized DCIN...
  • Page 331 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine input 24V common] Machine side FCU8-DX220/230/231/651 Machine side FCU8-DX230/231 CJ31 CJ33 DICOM DICOM +24V +24V +24V +24V Stabilized Stabilized power supply power supply 24VDC(+) DICOM 24VDC(+) DICOM Stabilized Stabilized DCIN...
  • Page 332 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine output : FCU8-DX220 / FCU8-DX230 / FCU8-DX651] Machine side FCU8-DX220/230/651 Machine side FCU8-DX230 CJ32 CJ34 +24V +24V +24V +24V Stabilized Stabilized DCIN DCIN power supply power supply 24VDC(+) +24V 24VDC(+)
  • Page 333 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine output : FCU8-DX231] Machine side FCU8-DX231 Machine side FCU8-DX231 CJ32 CJ34 +24V +24V +24V +24V Stabilized Stabilized DCIN DCIN power supply power supply 24VDC(+) +24V 24VDC(+) +24V IB-1501269-J...
  • Page 334: Connecting With Machine Control Signal (Fcu8-Dx213 / Fcu8-Dx213-1 / Fcu8-Dx654 / Fcu8-Dx654-1)

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.7 Connecting with Machine Control Signal (FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1) [FCU8-DX213 / FCU8-DX213-1 / FCU8-DX654 / FCU8-DX654-1] FCU8-DX213 / 213-1 : CJ35 <Applicable cable> FCU8-DX654 / 654-1 : Solid wire : 0.08 - 1.5 mm Twisted wire...
  • Page 335 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Mounting the wire] (1) Insert a slotted screwdriver (blade width: 2.5mm). (2) Insert the wire and then pull the screwdriver out. [Mounting the connector] (1) Push the connector to the lock lever position. (2) Push the right and left lock levers up simultaneously.
  • Page 336 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine input (wiring example 1) : FCU8-DX213 / FCU8-DX213-1] Machine side FCU8-DX213/213-1 CJ35 COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ Stabilized CJ36...
  • Page 337 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine input (wiring example 2) : FCU8-DX213 / FCU8-DX213-1] Machine side FCU8-DX213/213-1 CJ35 COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ COMA+ COMB+ Stabilized CJ36...
  • Page 338 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Machine output : FCU8-DX213 / FCU8-DX213-1] Machine side FCU8-DX213/213-1 CJ36 COMA- COMB- COMA- COMB- COMA- COMB- COMA- COMB- Stabilized power supply 24VDC(+) IO24VA IO0VA IO24VB IO0VB Stabilized DCIN power supply 24VDC(+) +24V...
  • Page 339 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Safety machine input (wiring example 1) : FCU8-DX654 / FCU8-DX654-1] Machine side FCU8-DX654/654-1 SX00A SX00B COMA+ COMB+ SX01A SX01B COMA+ COMB+ SX02A SX02B COMA+ COMB+ SX03A SX03B COMA+ COMB+ SX04A SX04B...
  • Page 340 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Safety machine input (wiring example 2) : FCU8-DX654 / FCU8-DX654-1] Machine side FCU8-DX654/654-1 SX00A SX00B COMA+ COMB+ SX01A SX01B COMA+ COMB+ SX02A SX02B COMA+ COMB+ SX03A SX03B COMA+ COMB+ SX04A SX04B...
  • Page 341 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Safety machine output : FCU8-DX654 / FCU8-DX654-1] Machine side FCU8-DX654/654-1 SY00A COMA- SY00B COMB- SY01A COMA- SY01B COMB- SY02A COMA- SY02B COMB- SY03A COMA- SY03B COMB- Stabilized power supply IO24VA 24VDC(+) IO0VA...
  • Page 342: Connecting With Safety Machine Control Signal (Fcu8-Dx651)

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.8 Connecting with Safety Machine Control Signal (FCU8-DX651) CAUTION 1. Connect the cable to the designated connector. Incorrect connections could damage the device. 2. Do not connect or disconnect the connection cables between each unit while the power is ON. [Safety DI input] Machine side FCU8-DX651...
  • Page 343 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Safety relay output] Machine side FCU8-DX651 SDO1 DC24V SYR00A SY00A SYR00A SX08A SY00B SDO2 SYR00B SX08B SYR00B Relay Feedback SDO1 DC24V SYR01A SY01A SYR01A SX09A SY01B SDO2 SYR01B SX09B SYR01B Relay Feedback...
  • Page 344: Connecting With Analog I/O Signal (Fcu8-Dx202)

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.9 Connecting with Analog I/O Signal (FCU8-DX202) For the analog input/output signals, connect J221 cable to the AIO1 connector of FCU8-DX202. The analog input/output signals are available to connect up to four points for the input, and up to one point for the output. J221 AIO1 <Related items>...
  • Page 345 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit Input/output circuit Machine side FCU8-DX202 AIO1 Shield Shell Stabilized DCIN power supply 24VDC(+) +24V CAUTION 1. Connect the cable to the designated connector. Incorrect connections could damage the device. 2.
  • Page 346: Connecting With Thermistor (Fcu8-Dx408)

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.10 Connecting with Thermistor (FCU8-DX408) Connect the thermistor with THERMISTOR connector. The maximum cable length is 25m. The recommended shield cable is "HK-SB/20276XL, black, LF 1P X 22AWG" made by Taiyo Cabletec. Thermistor Cable with shield THERMISTOR...
  • Page 347 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Thermistor cable connecting procedure] The thermistor cable has the following configuration: Thermistor Cable with shield THERMISTOR connector (1) Solder the thermistor to the shield cable and cover the joint surface with the protection tube. Tube for protection (2) Twist the shield of the cable or pull out the drain wire.
  • Page 348 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Connecting with thermistor:FCU8-DX408] FCU8-DX408 THERMISTOR Thermistor Thermistor CH1 Thermistor CH1 Shield Thermistor Thermistor CH2 Thermistor CH2 CH12 Thermistor Thermistor CH12 Thermistor CH12 DCIN Stabilized power supply 24VDC(+) +24V IB-1501269-J...
  • Page 349: Connecting With Multi-Analog Input Signal (Fcu8-Dx409)

    M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit 10.11 Connecting with Multi-analog Input Signal (FCU8-DX409) There are four types of multi-analog input signals as below: - Voltage input signal - Current input signal - Thermocouple input signal - Resistance temperature detector input signal Connect these signals to AI connector.
  • Page 350 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit AI : DFMC1,5/12-ST-3,5-LR (Phoenix Contact) <Applicable cable> Solid wire : 0.2-1.5mm Twisted wire : 0.2-1.5mm Bar terminal with insulation collar : 0.25-0.75mm Bar terminal without insulation collar : 0.25-1.5mm Stripping line length : 10mm <Wire mounting tool (driver) type>...
  • Page 351 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit [Mounting the wire] (1) Push in the wire opening lever (orange) using a slotted screwdriver (blade width: 2.5mm). (2) Insert the wire and then pull the screwdriver out of the wire opening lever. [Mounting the connector] (1) Push the connector to the lock and release (LR) lever position.
  • Page 352 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit (a) Connecting with the voltage input signal Machine side FCU8-DX409 Shield Shield Shield Shield DCIN Stabilized power supply 24VDC(+) +24V - Use the twisted cable with shield to reduce the influence of noise. - Connect the shield to FG pin of AI connector.
  • Page 353 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit (b) Connecting with the current input signal Machine side FCU8-DX409 Shield Shield Shield Shield DCIN Stabilized power supply 24VDC(+) +24V - Use the twisted cable with shield to reduce the influence of noise. - Connect the shield to FG pin of AI connector.
  • Page 354 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit (c) Connecting with the thermocouple input signal FCU8-DX409 Cold junction compensation resistor Thermocouple (Pt100) Shield Cold junction compensation resistor (Pt100) 2cm or shorter Set the lead length 2cm or shorter including the length to insert to AI connector.
  • Page 355 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit (d) Connecting with the resistance temperature detector input signal There are 3-wire type and 4-wire type for the connecting method of resistance temperature detector. <3-wire type> FCU8-DX409 Resistance temperature detector Shield...
  • Page 356 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit <4-wire type> FCU8-DX409 Resistance temperature detector Shield Resistance temperature detector Shield Resistance temperature detector Shield Resistance temperature detector Shield DCIN Stabilized power supply 24VDC(+) +24V - Use the twisted cable with shield to reduce the influence of noise. - Connect the shield to FG pin of AI connector.
  • Page 357 M800S/M80/E80 Series Connection and Setup Manual 10 Connection of Remote I/O Unit IB-1501269-J...
  • Page 358: Connection Of Manual Pulse Generator

    Connection of Manual Pulse Generator IB-1501269-J...
  • Page 359: Manual Pulse Generator Connection System Drawing

    M800S/M80/E80 Series Connection and Setup Manual 11 Connection of Manual Pulse Generator The method for connecting to each unit and device from the manual pulse generator is briefly explained in this chapter. 11.1 Manual Pulse Generator Connection System Drawing Connecting to control unit (5V) Control unit 5V manual pulse generator J026/J027...
  • Page 360: Connecting With Control Unit

    M800S/M80/E80 Series Connection and Setup Manual 11 Connection of Manual Pulse Generator 11.2 Connecting with Control Unit 5V manual pulse generator (Rear view) NO.1 When connecting one 5V 5V 0V A B manual pulse generator J026 NO.1 NO.2 When connecting two 5V 5V 0V A B 5V 0V A B manual pulse generators...
  • Page 361 M800S/M80/E80 Series Connection and Setup Manual 11 Connection of Manual Pulse Generator (2) 12V manual pulse generator (maximum cable length: 50m) NO.1 When connecting one 12V manual pulse 12V manual pulse 12V 0V generator generator HD60C (Rear view) J020 Operation panel NO.2 NO.1 I/O unit...
  • Page 362: Connection Of Synchronous Feed Encoder

    Connection of Synchronous Feed Encoder IB-1501269-J...
  • Page 363: Synchronous Feed Encoder Connection System Drawing

    M800S/M80/E80 Series Connection and Setup Manual 12 Connection of Synchronous Feed Encoder The method for connecting to each unit and device from the synchronous feed encoder is explained in this chapter. 12.1 Synchronous Feed Encoder Connection System Drawing Control unit Synchronous feed encoder R050/R054 cable...
  • Page 364: Connection Of Mitsubishi Cnc Machine Operation Panel

    Connection of MITSUBISHI CNC Machine Operation Panel IB-1501269-J...
  • Page 365: Machine Operation Panel Connection System Drawing

    M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel This chapter briefly explains how to connect the MITSUBISHI CNC machine operation panel to each unit and device. (Note) In this chapter "MITSUBISHI CNC Machine operation panel" is shorten to Machine operation panel.
  • Page 366: Connecting With Power Supply

    24VDC(+) J070/J071 <Related items> Cable drawing: "Cable: J070/J071 Cable" Connector pin assignment: "General Specifications: MITSUBISHI CNC Machine Operation Panel: Main Panel A,B" (DCIN connector) When sharing the 24VDC power supply with the control unit, connect a 24VDC relay cable. [FCU8-KB921/KB922/KB923/KB924/KB925/KB926]...
  • Page 367: Connecting With Frame Ground

    When the remote I/O unit on the next stage is not relayed, connect the R2-TM terminal. <Related items> Cable drawing: "Cable: J010 Cable", "Cable: J210 Cable" Connector pin assignment: "General Specifications: MITSUBISHI CNC Machine Operation Panel: Main Panel A,B" (RIOIN/RIOOUT connector) IB-1501269-J...
  • Page 368: Connecting Emergency Stop Switch

    Emergency stop switch Machine operation panel (sub panel) <Related items> Cable drawing: "Cable: J121 Cable" Connector pin assignment: "General Specifications: MITSUBISHI CNC Machine Operation Panel: Sub Panel A" (emergency stop switch) 13.6 Connecting with Sub Panel Rapid traverse override G460...
  • Page 369 M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel <Wiring of rotary switch (SUBP)> Main panel A/B (FCU8-KB92x) Sub panel A (FCU8-KB931/KB941) [SUBP] Rotary Switch (For cutting feedrate override) 21 position Real gray code Rotary Switch...
  • Page 370 M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel <Wiring of other switches (SUBP)> Main panel A/B (FCU8-KB92x) [SUBP] Sub panel A (FCU8-KB931/KB941) Memory protection switch 2 notch Key shape 2c Manual return type Switch input spare...
  • Page 371: Software Interface

    M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel 13.7 Software Interface Station Nos. of the machine operation panel RIOs are fixed. Device Nos. such as switch and LED on the machine operation panel are fixed as follows:...
  • Page 372 M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel <Device No. of key switches> Key switch Device Key switch Device ZR5$24[0] ZR5$26[0] ZR5$24[1] ZR5$26[1] ZR5$24[2] ZR5$26[2] ZR5$24[3] ZR5$26[3] ZR5$24[4] ZR5$26[4] ZR5$24[5] ZR5$26[5] ZR5$24[6] ZR5$26[6] ZR5$24[7]...
  • Page 373 M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel <Device No. of LED> Device Device ZR6$24[0] ZR6$26[0] ZR6$24[1] ZR6$26[1] ZR6$24[2] ZR6$26[2] ZR6$24[3] ZR6$26[3] ZR6$24[4] ZR6$26[4] ZR6$24[5] ZR6$26[5] ZR6$24[6] ZR6$26[6] ZR6$24[7] ZR6$26[7] ZR6$24[8] ZR6$26[8] ZR6$24[9] ZR6$26[9]...
  • Page 374 M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel (2) Sub panel Sub panel is equipped with cutting override, rapid traverse override, memory protection switch and emergency stop switch. Direct wiring is available for the emergency stop switch, and device numbers for the other switches are...
  • Page 375 M800S/M80/E80 Series Connection and Setup Manual 13 Connection of MITSUBISHI CNC Machine Operation Panel IB-1501269-J...
  • Page 376: Connection Of Handy Terminal

    Connection of Handy Terminal IB-1501269-J...
  • Page 377: Handy Terminal Connection System Drawing

    M800S/M80/E80 Series Connection and Setup Manual 14 Connection of Handy Terminal This chapter briefly explains how to connect the handy terminal to each unit and device. 14.1 Handy Terminal Connection System Drawing Handy terminal Control unit G430 cable HOST 14.2 Connecting with Control Unit Connect the handy terminal to SIO connector and ENC connector of the control unit.
  • Page 378: Cable

    Cable IB-1501269-J...
  • Page 379: Symbols For Writing Cable Drawings

    (5) Equivalent parts can be used for the connector, contact and wire material. (6) The tolerances of the cables provided by MITSUBISHI are as follows: Cable length (mm) Tolerances (mm) ±30...
  • Page 380: Cable Relating To Nc

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2 Cable Relating to NC 15.2.1 FCUA-R050/R054 Cable Max. cable length: 30m Application: Synchronous encoder - control unit FCUA-R050 FCUA-R054 ENC1 ENC1A (ENC2A) ENC1A*(ENC2A*) ENC1B (ENC2B) ENC1B*(ENC2B*) ENC1Z (ENC2Z) ENC1Z*(ENC2Z*) [FCUA-R050 cable] Connector: MS3106B20-29S Cable clamp: MS3057-12A [ENC1]...
  • Page 381: G071 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.2 G071 Cable Max. cable length: 1m Application: 24VDC relay cable for MITSUBISHI CNC machine operation panel DCOUT DCIN R : Red W : White G : Green [DCOUT] [DCIN] Connector: 2-178288-3...
  • Page 382: G430 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.4 G430 Cable Max. cable length: 10m Application: For connection to handy terminal HOST Control unit Handy terminal Cotrol panel terminal block HOST HA1A HA1B SD(TXD) RD(RXD) SD(TXD) RD(RXD) CS(CTS) RS(RTS) RS(RTS) CS(CTS) DR(DSR) ER(DTR)
  • Page 383: G460 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.5 G460 Cable Max. cable length: 0.5m Application: Cable for MITSUBISHI CNC machine operation panel (cable between main panel and sub panel) RSW1 SUBP RSW2 SW-NO SW-NO SW-C SW-C [RSW1][RSW2] 1 : Purple...
  • Page 384: J010 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.6 J010 Cable Max. cable length: 1m Application: Operation panel I/O interface cable CJ71 CJ71 CJ71 CJ71 TXRXD TXRXD TXRXD* TXRXD* 3.3V 3.3V Drain wire Drain wire AWG22×3P (With shield / drain wire) [CJ71] Connector : 2-1318119-4 Wire material : HRZEV-SB-A(20276) AWG22×3P...
  • Page 385: J020/J021/J022 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.8 J020/J021/J022 Cable Max. cable length: 50m Application: Manual Pulse Generator cable (12V) HA1A HA1B +12V 12V1 HA2A HA2B +12V 12V2 HA3A HA3B 12V3 +12V [MPG] Wire material : [1ch][2ch][3ch] Connector : 10120-3000PE UL2464 U-TKVVBS AWG24 ×...
  • Page 386: J023/J024/J025 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.9 J023/J024/J025 Cable Max. cable length: 20m Application: Manual Pulse Generator cable (5V) HA1A HA1B HA2A HA2B HA3A HA3B [MPG] Wire material : [1ch][2ch][3ch] Connector : 10120-3000PE UL2464 U-TKVVBS AWG22 × 6P Crimp terminal : V1.25-3 ×...
  • Page 387: J026/J027 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.10 J026/J027 Cable Max. cable length: 20m (the maximum length of the cable when connected to the control unit via other units) Application: Manual Pulse Generator cable (5V) HA1A HA1B HA2A HA2B [MPG] Wire material : [1ch][2ch]...
  • Page 388: J030/J031 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.11 J030/J031 Cable Max. cable length: 15m (the maximum length of the cable when connected to the control unit via other units) Application: RS232C I/F cable SIO1 SIO2 SIO1 SD1(TXD1) SD(TXD) RD1(RXD1) RD(RXD) RS1(RTS1) RS(RTS)
  • Page 389: J070/J071 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.12 J070/J071 Cable Max. cable length: 15m(J070) / 20m(J071) Application: 24VDC power cable DCIN DCIN +24V +24V [J070 cable] Wire material : 2464C BIOS-CL3-16 02C × 16AWG(26/0.26) [DCIN] Recommended manufacturer : BANDO DENSEN Connector : 2-178288-3 Crimp terminal : R1.25-4 ×...
  • Page 390: J100 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.13 J100 Cable Max. cable length: 20m Application: Skip SKIP SKIP SKIP0 SKIP1 SKIP2 SKIP3 SKIP4 SKIP5 SKIP6 SKIP7 [SKIP] Wire material : Connector : 10120-3000PE UL2464 U-TKVVBS AWG24 × 6P Crimp terminal : R1.25-3.5 ×...
  • Page 391: J120 Cable

    Recommended manufacturer : JST (former model number: 50084-8160) BANDO DENSEN Recommended manufacturer : MOLEX 15.2.15 J121 Cable Max. cable length: 30m Application: Emergency stop cable for MITSUBISHI CNC machine operation panel Faston terminal#110 EMG IN White [EMG] Wire material :...
  • Page 392: J210 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.16 J210 Cable Max. cable length: 50m Application: Remote I/O 2.0 communication cable TXRXD TXRXD TXRXD* TXRXD* Drain wire Drain wire (With shield / drain wire) AWG22×2P [RIO] Connector : 1-1318119-3 Wire material : HK-SB/20276XL Black LF 2P × 22AWG Contact : 1318107-1 Recommended manufacturer : Recommended manufacturer :...
  • Page 393: J221 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.17 J221 Cable Max. cable length: 30m Application: Analog input/output cable (for remote I/O unit) AI0G AI1G AI2G AI3G AI0G AI1G AI2G AI3G [AIO] Wire material : Connector : 10120-3000PE UL2464 U-TKVVBS AWG24 × 6P Crimp terminal : R1.25-3.5 x 10 Case : 10320-52F0-008 Recommended manufacturer :...
  • Page 394: J224 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.18 J224 Cable Max. cable length: 30m Application: Analog input/output cable (for operation panel I/O unit) AI0G [AIO] Wire material : Connector : 10120-3000PE UL2464 U-TKVVBS AWG24 × 6P Crimp terminal : R1.25-3.5 x 10 Case : 10320-56F0-008 Recommended manufacturer :...
  • Page 395: J225 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.19 J225 Cable Max. cable length: 30m Application: Analog output cable (for operation panel I/O unit) [AO] Wire material : Connector : 10120-3000PE UL2464 U-TKVVBS AWG24 × 1P Crimp terminal : R1.25-3.5 x 2P Case : 10320-52F0-008 Recommended manufacturer : Recommended manufacturer : JST...
  • Page 396: J350 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.21 J350 Cable Max. cable length: 50m Application: DI/DO CG31,CG32,CG35,CG36, CJ31,CJ32,CJ33,CJ34, CJ38,CJ40,CJ42 [CG31,CG32,CG35,CG36,CJ31,CJ32,CJ33,CJ34,CJ38,CJ40,CJ42] Connector: XG4M-4030 / 7940-6500SC Wire material: UL2651 AWG28x40 (FLEX-S(40)-7/0.127 7030 Strain relief: XG4T-4004 / 3448-7940 2651P) Recommended manufacturer: OMRON / 3M Recommended manufacturer: Oki Electric Cable 15.2.22 J351 Cable Max.
  • Page 397: J460 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.2.23 J460 Cable Max. cable length: 50m Application: DI/DO CJ37,CJ39 [CJ37,CJ39] Wire material: UL2651 AWG28x50 (FLEX-S(50)-7/0.127 7030 Connector: XG4M-5030 / 7950-6500SC 2651P) Strain relief: XG4T-5004 / 3448-7950 Recommended manufacturer: Oki Electric Cable Recommended manufacturer: OMRON / 3M (Note) This cable is used to connect the operation panel I/O unit.
  • Page 398: R2-Tm Terminator Connector

    Recommended manufacturer: Tyco Electronics Resistor: 110Ω 1/4W (Note 1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing they are compatible with the specifications. (Note 2) Cover the 110Ω terminator with a black insulation tube.
  • Page 399: Cable Relating To Drive Unit

    15.3.1 Cable Wire and Assembly (1) Cable wire The specifications of the wire used for each cable, and the machining methods are shown in this section. The Mitsubishi designated cable is the recommended cables shown below. When manufacturing the encoder cable and battery connection cable, use the recommended wires shown below or equivalent products.
  • Page 400: Cnp2E-1 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.2 CNP2E-1 Cable Max. cable length: 30m Application: Motor side PLG cable Spindle side accuracy encoder TS5690 cable Spindle drive unit side connector (3M) Spindle motor side connector   Receptacle: 36210-0100PL (Tyco Electronics) Shell kit: 36310-3200-008 Connector: 172169-1 (MOLEX)
  • Page 401: Cnp3Ez-2P/Cnp3Ez-3P Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.3 CNP3EZ-2P/CNP3EZ-3P Cable Max. cable length: 30m Application: Spindle side encoder cable OSE-1024 cable CNP3EZ-2P (Straight) CNP3EZ-3P (Angle) Spindle drive unit side connector Spindle motor side connector (3M)   (DDK) Receptacle: 36210-0100PL Connector: MS3106A20-29S (D190) Shell kit: 36310-3200-008 Back shell: CE02-20BS-S (straight)
  • Page 402: Cnv2E-8P/Cnv2E-9P Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.4 CNV2E-8P/CNV2E-9P Cable Max. cable length: 30m Application: For HF/HF-H, HF-KP (Tool spindle) Motor side encoder cable (for A48/A51/A74N(/A74)) / For HF-KP (Servo) Motor side encoder relay cable (Drive unit side) (CNV2E-8P) CNV2E-8P (Straight) CNV2E-9P (Angle) Motor encoder/...
  • Page 403: Cnv2E-D Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.5 CNV2E-D Cable Max. cable length: 30m Application: MDS-B-SD unit cable Drive unit side connector (3M)   Receptacle: 36210-0100PL MDS-B-SD unit side connector Shell kit: 36310-3200-008 (3M) (MOLEX) Connector: 10120-3000VE Connector set: 54599-1019 Shell kit: 10320-52F0-008 0.5mm P5(+5V)
  • Page 404: Dg30 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.7 DG30 Cable Max. cable length: 10m Application: Battery cable (drive unit - battery box, drive unit - drive unit) Drive unit side connector Drive unit side connector (J.S.T) (J.S.T)   Connector: PAP-02V-O Connector: PHR-2-BL Contact: SPHD-001G-P0.5 Contact: SPH-0022GW-P0.5S...
  • Page 405: J395 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.9 J395 Cable Max. cable length: 10m Application: Optical communication cable for wiring between drive units (outside panel) for wiring between NC-drive units Use when wiring outside of the panel with a cable of 10m or less. [OPT] Connector : LGP-Z0007PK Wire material : PFDU-CL1002-22E60VT...
  • Page 406: J396 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.10 J396 Cable Max. cable length: 10m Application: Optical communication cable for wiring between drive units (inside panel) Use when wiring in the panel with a cable of 10m or less. [OPT] Connector : LGP-Z0007PK Wire material : PFDU-CD1002-18E22T Recommended manufacturer :...
  • Page 407: Mr-Bks1Cbl-A1-H / Mr-Bks1Cbl-A2-H Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.11 MR-BKS1CBL-A1-H / MR-BKS1CBL-A2-H Cable Max. cable length: 10m Application: <200V Series> Brake cable for HG96 MR-BKS1CBL-A1-H (load side angle) MR-BKS1CBL-A2-H (reverse load side angle) Servo motor brake connector (Japan Aviation Electronics) Connector: JN4FT02SJ1-R Hood, Socket insulator, Bushing and Ground nut...
  • Page 408: Mr-D05Udl3M-B Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.13 MR-D05UDL3M-B Cable Max. cable length: 3m Application: STO cable Drive unit side (Tyco Electronics) Connector set: MR-D05UDL3M-B Yellow (Dot mark: Red) STO1 STO1 input Gray (Dot mark: Black) STO2 input STO2 Yellow (Dot mark: Black) STOCOM Gray (Dot mark: Red)
  • Page 409: Sh21 Cable

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.3.15 SH21 Cable Max. cable length: 30m Application: Power supply communication cable Power backup unit communication cable CN4, CN9 SVTXD SVTXD SVTXD* SVTXD* SVALM SVALM SVALM* SVALM* SVRXD SVRXD SVRXD4 SVRXD4 SVEMG SVEMG SVEMG* SVEMG*...
  • Page 410: List Of Cable Connector Sets

    M800S/M80/E80 Series Connection and Setup Manual 15 Cable 15.4 List of Cable Connector Sets Type Application Package contents Connector (3M) Shell kit (3M) 10120-3000PE x 2pcs. 10320-52F0-008 x 2pcs. General I/O units FCUA-CS000 (For SKIP,SIO,MPG,AIO) Gold contact (MOLEX) Connector (MOLEX) 0016020103 x 3 pcs.
  • Page 411 M800S/M80/E80 Series Connection and Setup Manual 15 Cable IB-1501269-J...
  • Page 412: Setup Outline

    Setup Outline IB-1501269-J...
  • Page 413: Hardware Configuration

    M800S/M80/E80 Series Connection and Setup Manual 16 Setup Outline 16.1 Hardware Configuration The following shows the hardware names used in this manual. [Example of 15-type] (A) Cancel key (B) Menu changeover key (C) Front-side SD card I/F (D) USB Interface (E) [INPUT] key IB-1501269-J...
  • Page 414 M800S/M80/E80 Series Connection and Setup Manual 16 Setup Outline [M800S] [M80/E80] (A) 7-segment LED (B) Rotary switch IB-1501269-J...
  • Page 415: Flow Of Initial Setup

    M800S/M80/E80 Series Connection and Setup Manual 16 Setup Outline 16.2 Flow of Initial Setup The following flow chart shows the procedures of the initial setup. (Note) When setting up with backup files, refer to the chapter of "Data Backup and Restoration". WARNING Do not cancel the emergency stop before confirming the basic operation.
  • Page 416 M800S/M80/E80 Series Connection and Setup Manual 16 Setup Outline For other settings, refer to the following chapters: - Setting the Deceleration Check - Adjust S-analog Screen - Device Open Parameter Screen - SRAM Open Parameter Screen - Data Backup and Restoration When using the system lock, refer to the chapter of "Appendix 1: Setting the System Lock".
  • Page 417 M800S/M80/E80 Series Connection and Setup Manual 16 Setup Outline IB-1501269-J...
  • Page 418: Setting The Hardware

    Setting the Hardware IB-1501269-J...
  • Page 419: Setting Drive Unit Mds-E/Eh Series

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.1 Setting Drive Unit MDS-E/EH Series 17.1.1 Setting the Rotary Switch Set the axis number with the rotary switch. <Drive unit> 1-axis 2-axis 3-axis 1-axis 2-axis servo drive unit servo drive unit servo drive unit spindle drive unit spindle drive unit...
  • Page 420: Setting Dip Switch

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware <Power supply unit> Power supply unit (MDS-E/EH-CV) MDS-E/EH-CV setting Rotary switch setting Setting items Normal setting Setting prohibited 1 ~ 3 External emergency stop setting Setting prohibited 5 ~ F 17.1.2 Setting DIP Switch As a standard setting, turn the all DIP switches OFF.
  • Page 421: Setting Drive Unit Mds-Em/Emh Series

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.2 Setting Drive Unit MDS-EM/EMH Series 17.2.1 Setting the Rotary Switch Set the axis number with the rotary switch. < Drive unit > Multi axis unit (MDS-EM/EMH-SPV3) MDS-EM/EMH-SPV3 setting Servo Rotary switch setting Axis configuration Spindle...
  • Page 422: Setting Drive Unit Mds-Ej/Ejh Series

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.3 Setting Drive Unit MDS-EJ/EJH Series 17.3.1 Setting the Rotary Switch Set the axis number with the rotary switch. 1-axis 1-axis 1-axis 2-axis servo/ servo drive unit pindle drive unit servo drive unit pindle drive unit...
  • Page 423: Setting The Dip Switch

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware MDS-EJ-V2/SP2 setting AXIS NO. Rotary switch setting L axis M axis 1st axis 2nd axis 2nd axis 3rd axis 3rd axis 4th axis 4th axis 5th axis 5th axis 6th axis 6th axis 7th axis 7th axis...
  • Page 424: Setting Up Without Connecting To The Motor/Drive Units At The Startup Of Drive Unit

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.4 Setting Up without Connecting to the Motor/Drive Units at the Startup of Drive Unit When connecting the motor or drive unit after setting up the system, set the axis data beforehand to enable the operation without the motor or drive unit.
  • Page 425: Connecting The Batteries

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.5 Connecting the Batteries 17.5.1 Control Unit Battery The battery is not connected when the machine is delivered. Be sure to connect the battery before starting up. A lithium battery in the control unit battery holder retains parameter settings, machining programs and the like, which requires to be backed up at the power OFF.
  • Page 426 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware [Installation method] (1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.) (2) Confirm that the control unit LED, 7-segment display, etc., are all OFF. (3) Open the front cover of the control unit.
  • Page 427: Servo Drive Unit Battery

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.5.2 Servo Drive Unit Battery (Note) The battery connection is not necessary unless the drive unit employs absolute position detection. (Spindle drive unit does not require the battery, because the unit does not employ absolute position detection.) There are batteries as shown below.
  • Page 428 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware MDS-EM Connect the battery connector to the connector BTI of the drive unit. MR-BAT6V1SET Battery connector connection part magnified figure Connect the battery box with BTI. IB-1501269-J...
  • Page 429 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware MDS-EJ/EJH-Vx Connect the battery connector to the connector BAT of the drive unit. Insert the plug to BAT Pull out the connector while after installing the battery. pushing the unlocking lever. Slide the case of MR-BAT6V1SET toward you while pushing the unlocking lever.
  • Page 430: Connecting And Setting The Remote I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6 Connecting and Setting the Remote I/O Unit 17.6.1 Outline of the Remote I/O Unit The specification varies for each remote I/O unit. Each unit has one or two rotary switch(es) for unit No. setting, which links the device Nos.
  • Page 431 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware Number of Unit type Machine control signals that can be handled Total occupied stations Digital input signal (DI) 32 points FCU8-DX220 Digital output signal (DO) 32 points Digital input signal (DI) 64 points FCU8-DX230 Digital output signal (DO)
  • Page 432: Connection And Station No. Setting On Remote I/O Unit

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6.2 Connection and Station No. Setting on Remote I/O Unit When connecting directly to the control unit Control unit Remote I/O unit Remote I/O 1ch RIO1 J210 Max.64 stations Max. input: 2048 points Max.
  • Page 433 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware (Note 1) A remote I/O unit has two slide switches (station No. group setting switches) and one rotary switch (station No. setting switch) for station No. setting, which link the device Nos. (with X/Y). Set the slide switches and the rotary switch as follows.
  • Page 434 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware When connecting to the operation panel I/O unit Control unit RIO occupied stations FCU8-DX731: Operation panel I/O unit 1, 3, 7 to 12, 20 to 22 FCU8-DX750: Remote I/O unit 1 to 3, 7 to 12, 20 to 22 FCU8-DX760: 1 to 4, 7 to 12, 20 to 22...
  • Page 435: Station No. Setting When Using Multiple Remote I/O Units

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6.3 Station No. Setting when Using Multiple Remote I/O Units Multiple remote I/O units can be used, as long as the total No. of occupied stations connected with serial links is eight or less.
  • Page 436 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware Setting example 2 Remote I/O unit Control unit FCU8-DX23□, FCU8-DX654, FCU8-DX654-1 Group1 1:OFF 2:OFF Group2 1:OFF 2:ON Group3 1:ON 2:OFF Group4 1:ON 2:ON Setting example 3 Control unit Safety remote I/O unit with built-in relay FCU8-DX651 Station No.
  • Page 437 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware Setting example 4 Multi-analog input unit Control unit FCU8-DX409 Group1 1 : OFF 2 : OFF IB-1501269-J...
  • Page 438 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware When connecting to the operation panel I/O unit Operation panel I/O unit occupies 9 to 11 stations among station No. 1 to 64. Therefore, RIO3 can occupy up to 50 to 53 stations, as shown below. Max.
  • Page 439: Plc Device Assignment Of Digital Signal (Di/Do)

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6.4 PLC Device Assignment of Digital Signal (DI/DO) The input/output signals (analog signal, DI/DO, etc.) are assigned to the PLC devices, and the digital signals (DI/DO) can be assigned to the arbitrary PLC devices by the parameters. Either "Fixed device assignment"...
  • Page 440: Fixed Device Assignment

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6.4.1 Fixed Device Assignment (1) By setting the parameter "#53001 RIO dev assign" to "0", the PLC device assignment method, which is to be used for input/output of each remote I/O unit station, will be the fixed device assignment. (2) PLC devices assigned for each remote I/O unit station at the time of the fixed device assignment are as follows: Station No.
  • Page 441: Arbitrary Device Assignment

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6.4.2 Arbitrary Device Assignment Parameter setting for device arbitrary assignment (1) By setting the parameter "#53001 RIO dev assign" to "1", the assignment method for PLC devices to be used for input/output of each remote I/O unit station becomes arbitrary device assignment.
  • Page 442 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware (7) Up to 24 stations can be specified for high-speed input/output specification each for input and output. If 25 or more stations are specified, the alarm "Y05 Initial parameter error" will be issued. (8) High-speed input/output specification can be set by R registers below as well as the RIO assignment parameters.
  • Page 443 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware (e) The RIO assignment parameters have not been specified to the remote I/O unit stations with DI/DO functions (except safety DI/DO) that are connected to NC. Two or more stations of the PLC devices are set redundantly to the RIO assignment parameters. (Note) However, these (a) to (f) will not be issued with the alarm "Y05 Initial parameter error"...
  • Page 444 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware Operating parameter setting screen (1) RIO assignment parameter setting rule (a) For arbitrary device assignment, assign PLC devices to all stations which are connected to the remote units with DI/DO function. Devices can be assigned in random order for arbitrary device assignment. It is unnecessary to assign in order of the target channels, target station numbers, PLC devices, etc.
  • Page 445: Thermistor Input Interface

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.6.5 Thermistor Input Interface (1) By connecting the remote I/O unit with thermistor, up to 12 points of thermistor input are available. For details on the unit which has thermistor input function, refer to "General Specifications: Remote I/O Unit". (2) Up to 12 points of thermistor are detected in the ascending order of the channel No.
  • Page 446: Initializing The Nc Internal Data (Sram)

    M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware 17.7 Initializing the NC Internal Data (SRAM) The initialization does not affect the settings of the option parameters. (Note) The DIP switches next to the rotary switch are for our adjustment. Do not change them after the shipment. Normally the switches No.
  • Page 447 M800S/M80/E80 Series Connection and Setup Manual 17 Setting the Hardware (Note 1) After the initializing and the NC power ON, the IP address is initialized as follows. <Base specification parameter> #1934 Local IP address: 192.168.100. 1 Failure to communicate with the screen may be caused by inconsistency between the parameter value and the "C:\WINDOWS\melcfg.ini"...
  • Page 448: Setting Up With M80/M800S Setup Installer

    Setting Up with M80/M800S SETUP INSTALLER IB-1501269-J...
  • Page 449 MITUBISHI will not provide performance guarantee and maintenance for commercially available SD card. In the case of using a commercially available SD card, careful performance check must be required by the machine tool builder. Commercially available devices may not be compatible with MITSUBISHI units or suitable FA environment for temperature or noise-wise.
  • Page 450: Activate M80/M800S Setup Installer

    M800S/M80/E80 Series Connection and Setup Manual 18 Setting Up with M80/M800S SETUP INSTALLER 18.1 Activate M80/M800S SETUP INSTALLER (1) Write the data for M80/M800S SETUP INSTALLER into an SD card. The data configuration is as illustrated below. Installer (Execution file) installer.o (Custom data folder) custom (PLC alarm message folder)
  • Page 451 M800S/M80/E80 Series Connection and Setup Manual 18 Setting Up with M80/M800S SETUP INSTALLER APLC C language module The size of APLC C language module must be 120KB or less. User cycle For details of user cycle, refer to "M800/M80 Series Interactive Cycle Insertion (Customization) Specification manual"...
  • Page 452: Install Custom Screen

    M800S/M80/E80 Series Connection and Setup Manual 18 Setting Up with M80/M800S SETUP INSTALLER 18.2 Install Custom Screen Carry out the procedures of this section to register custom screens. When you use standard screens only, there is no need to carry out the procedure. Push the [Custom Data] menu.
  • Page 453: Install Start-Up Screen

    M800S/M80/E80 Series Connection and Setup Manual 18 Setting Up with M80/M800S SETUP INSTALLER 18.3 Install Start-up Screen Carry out the procedures of this section to register custom start-up screen. When you use standard start-up screen, there is no need to carry out the procedures. (1) Push the [Custom Startup] menu.
  • Page 454: Install Aplc C Language Module

    M800S/M80/E80 Series Connection and Setup Manual 18 Setting Up with M80/M800S SETUP INSTALLER 18.4 Install APLC C Language Module Carry out the procedures of this section to register APLC C language module. When you do not use APLC C language module, there is no need to carry out the procedure.
  • Page 455: Install User Cycle

    M800S/M80/E80 Series Connection and Setup Manual 18 Setting Up with M80/M800S SETUP INSTALLER 18.5 Install User Cycle Carry out the procedures of this section to register user cycle. When you do not use user cycle, there is no need to carry out the procedure.
  • Page 456: Setting The Parameters And Date/Time

    Setting the Parameters and Date/Time IB-1501269-J...
  • Page 457: Selecting The Nc System Type And Displayed Language

    M800S/M80/E80 Series Connection and Setup Manual 19 Setting the Parameters and Date/Time WARNING Confirm the emergency stop state before carrying out the steps in this chapter. Refer to the section of "Alarm/Parameter Manual" for the details of the parameters. You can also refer to the parameter guidance display. Normally, the initial setting of NC is performed with NC Configrator2.
  • Page 458: Setting The Parameters For The System Specifications

    M800S/M80/E80 Series Connection and Setup Manual 19 Setting the Parameters and Date/Time 19.2 Setting the Parameters for the System Specifications (1) On the Mainte screen, select [Mainte] and then [Psswd input]. Enter the machine parameter password in the setting area and press the [INPUT] key. (2) Go back to the Mainte screen.Then select [Param].
  • Page 459: Setting The Parameters For The Machine Specifications

    M800S/M80/E80 Series Connection and Setup Manual 19 Setting the Parameters and Date/Time 19.3 Setting the Parameters for the Machine Specifications (1) On the Mainte screen, select [Mainte] and then [Psswd input]. Enter the machine parameter password in the setting area and press the [INPUT] key. (Note 1) To enter the character "A", press the shift key and then "A"...
  • Page 460 M800S/M80/E80 Series Connection and Setup Manual 19 Setting the Parameters and Date/Time Configuration example for seven part systems (Number of axes per part system: 8, 1, 1, 1, 1, 1, 3) (Assumed to use the device of each part system in the ladder as follows:) $1 Axis 1 [Axis 1] →...
  • Page 461: Setting Date And Time

    M800S/M80/E80 Series Connection and Setup Manual 19 Setting the Parameters and Date/Time 19.4 Setting Date and Time (1) Select [Time] on the Monitr screen. (2) Select [Time setting] on the integrated time screen. The time setting mode is entered. The cursor appears at the "#1 Date" position in the Run-out time display. (3) Set the date and time to "#1 Date"...
  • Page 462: Sequence Program Writing

    Sequence Program Writing IB-1501269-J...
  • Page 463: Writing Sequence Program Using The Sd Card

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing Sequence program writing is executed by connecting a personal computer, in which GX Developer or GX Works2 has been installed, to the control unit. Refer to the "PLC Development Manual" for details. 20.1 Writing Sequence Program using the SD Card Save the sequence program in an SD card and write the data to NC using the external file operations on PLC onboard.
  • Page 464 M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing (3) "Local Area Connection Status" is displayed. Click [Properties]. (4) Click "Internet Protocol Version 4 (TCP/IPv4)" on the [Networking] tab, and then click [Properties]. IB-1501269-J...
  • Page 465: Connecting The Control Unit And A Personal Computer

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing (5) Take a note of the displayed IP address and subnet mask. (6) Set the following addresses. (Note) (Example) IP address: 192.168.200.2 Subnet mask: 255.255.255.0 (Note) In the section "20.2.1 Confirming the IP Address for CNC", set an IP address in the range of "192.168.200.0"...
  • Page 466: Setting The Communication With Gx Developer

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.4 Setting the Communication with GX Developer (1) Perform the following operations with GX Developer to start the setup screen. [Online] -> [Transfer setup...] (2) Set the following items in order. (a) For the machine sequence Setting item Setting content...
  • Page 467 M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing (b) For the user safety sequence Setting item Setting content Remark PC side I/F Ethernet board Network No. Station No. Protocol PLC side I/F CPU unit CPU mode QCPU (Q mode) Ethernet port direct connection Not check IP address...
  • Page 468: Setting The Parameters On Gx Developer

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.5 Setting the Parameters on GX Developer (Note) There are two methods of ladder programming; independent program method and multi-program method, which makes differences in parameter settings. An incorrect parameter setting in the ladder programming may cause a write error.
  • Page 469: Setting The Number Of Device Points

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.5.2 Setting the Number of Device Points After creating a sequence program management area (project), the number of device points to be used in the project must be set first. This operation is required every time when a new project is created. For details on each setting item, refer to the "PLC Programming Manual".
  • Page 470: Setting The Number Of Common Pointer Points

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.5.3 Setting the Number of Common Pointer Points The number of common pointer points for each sequence program must be set for creating the sequence program with the multi-program method. This operation is required every time when a new project is created, and the parameter file must be written to the CNC controller.
  • Page 471: Setting The Program Execution Order

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.5.4 Setting the Program Execution Order When creating the sequence programs with the multi-program method, the execution method and execution order of each sequence program must be set. This operation is carried out before the sequence program is executed with the CNC controller.
  • Page 472: Writing A Sequence Program With Gx Developer

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.6 Writing a Sequence Program with GX Developer (Note) This operation is for performing writing in the temporary storage area of CNC (RAM inside CNC). The temporary storage area (RAM inside CNC) does not hold data after the power is turned OFF. If the data need to be held even after the power OFF, write the sequence program in ROM inside CNC following the procedure described in "Writing a Sequence Program to ROM with GX Developer".
  • Page 473 M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing [Operation procedure for a project "with labels"] The following is the operation procedure for label programming. (1) Perform the following operation from GX Developer to start the operation screen. [Online] -> [Write to PLC] (2) On the following screen, choose the sequence program file to be written from the [File selection] tab and click [Execute].
  • Page 474: Writing A Sequence Program To Rom With Gx Developer

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.7 Writing a Sequence Program to ROM with GX Developer [Operation procedure] (1) Perform the following operation with GX Developer to start the operation screen. [Online] -> [Write to PLC (Flash ROM)] -> [Copy program memory data into ROM] (Note) Only "IC Card (ROM)"...
  • Page 475: Setting The Communication With Gx Works2

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.8 Setting the Communication with GX Works2 (1) Start the setting screen by the following operation in the navigation window on GX Works2. Select [Connection Destination], then double-click [Current Connection]. (2) Set the following items in the order of the list.
  • Page 476: Setting The Parameters On Gx Works2

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.9 Setting the Parameters on GX Works2 (Note) There are two methods of ladder programming; independent program method and multi-program method, which makes differences in parameter settings. An incorrect parameter setting in the ladder programming may cause a write error.
  • Page 477: Setting Device Points

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.9.2 Setting Device Points After creating an area (project) to manage sequence programs, set the number of the device points used in the project. This operation is required every time a new project is created. For details on each setting item, refer to the "PLC Programming Manual".
  • Page 478: Setting Common Pointer No

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.9.3 Setting Common Pointer No. Set the pointer No. common to sequence programs when creating sequence programs in multi-program method. This operation is required every time a new project is created, and parameter files must be written to the CNC controller. (Note) When not set, Common Pointer No.
  • Page 479: Setting Program Executing Order

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.9.4 Setting Program Executing Order When creating sequence programs in multi-program method, set the execution method and execution order of sequence programs. This operation is required before a sequence program is executed on the CNC controller, and parameter files must be written to the CNC controller.
  • Page 480: Writing A Sequence Program With Gx Works2

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.10 Writing a Sequence Program with GX Works2 (Note) This operation writes data to the temporary storage in the CNC (RAM in CNC). Data in temporary storage (RAM in CNC) are not retained after power OFF. To retain data after power OFF, write sequence programs to the ROM in the CNC according to "Writing a Sequence Program to ROM with GX Works2".
  • Page 481 M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing (Note2) If an attempt is made to remove the check from parameter and write sequence programs during PLC is running, the prompt "PLC is running. Do you want to force write of the files?" is displayed. The CNC only supports writing during RUN from the [Compile] menu;...
  • Page 482 M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing [Operating procedure for simple projects (with labels)] The operating procedure when "use label" is set is described below. (1) Start the operation screen by the following operation on GX Works2. [Online] ->...
  • Page 483: Writing A Sequence Program To Rom With Gx Works2

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.11 Writing a Sequence Program to ROM with GX Works2 [Operation procedure] (1) Start the operation screen by the following operation on GX Works2. [Online] -> [Export to ROM Format] (Note) Only [memory card (Flash)] is valid as [Target].
  • Page 484: Setting The Plc Parameters

    M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing 20.12 Setting the PLC Parameters Select [Bit select] on the Mainte screen and set the bit selection parameters from #6449 to #6452. See the following table for details of the parameters. Symbol name Setting and...
  • Page 485 M800S/M80/E80 Series Connection and Setup Manual 20 Sequence Program Writing IB-1501269-J...
  • Page 486: Confirming The Basic Operation

    Confirming the Basic Operation IB-1501269-J...
  • Page 487: Checking Inputs/Outputs And Alarms

    M800S/M80/E80 Series Connection and Setup Manual 21 Confirming the Basic Operation 21.1 Checking Inputs/Outputs and Alarms (1) Checking the input signals (a) Select [I/F dia] on the Diagn screen. (b) Confirm that signals turn ON/OFF properly on the IF Diagnosis screen. (2) Checking the alarm display (a) Select [Alarm] on the Diagn screen.
  • Page 488: Confirming Manual Operation

    M800S/M80/E80 Series Connection and Setup Manual 21 Confirming the Basic Operation 21.2 Confirming Manual Operation 21.2.1 Using the Manual Pulse Generator (1) Select the handle mode. (2) Set the handle feed magnification to a minimum value. (3) Cancel the emergency stop. Confirm the operation status displays "RDY". (Note 2) (Note 1) If any abnormal noise or vibration occurs, execute an emergency stop and take a measure against vibration.
  • Page 489: Servo Simplified Adjustment

    M800S/M80/E80 Series Connection and Setup Manual 21 Confirming the Basic Operation 21.3 Servo Simplified Adjustment 21.3.1 First Measure Against Vibration Setting the filter can reduce the vibration. (1) Select [Drv mon] and then [Servo unit] on the Diagn screen. See the displayed value in "AFLT frequency". (Note) The screen above is when NC parameters have default values.
  • Page 490: Nc Analyzer2

    M800S/M80/E80 Series Connection and Setup Manual 21 Confirming the Basic Operation 21.3.2 NC Analyzer2 Servo parameters can be automatically adjusted by measuring and analyzing the machine characteristics. Measurement and analysis are conducted by driving the motor using machining programs for adjustment or vibration signals.
  • Page 491 M800S/M80/E80 Series Connection and Setup Manual 21 Confirming the Basic Operation IB-1501269-J...
  • Page 492: Setting The Position Detection System

    Setting the Position Detection System IB-1501269-J...
  • Page 493: Adjusting The Absolute Position Detection System

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System There are two kinds of position detection system: one is "relative position detection", which establishes the reference position (zero point) at every CNC power-ON; the other is "absolute position detection", which allows to start the operation without establishing the reference position (zero point) again after the CNC power-ON.
  • Page 494: Basic Position Alignment Method I

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.1.1 Basic Position Alignment Method I Preparations #2049 type (absolute position detection type) = 2 Set the parameters on the (marked point alignment method) [Abs.Posit.Param.] screen. #2050 absdir (basic point of Z direction) = 0/1 #2059 zerbas (select zero point parameter and basic point) =0 (position where the axis was stopped) (* 1) The parameters other than #2049 type can also be set on [Absolute...
  • Page 495 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System Move the cursor to "Zero-P" with the The input value is registered in the "Zero-P" area. [ ↑ ] and [ ↓ ] keys.Enter the value in the input area and press the [INPUT] key.
  • Page 496 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System The operation order is slightly different when "#2059 zerbas = 1 (grid point just before stopper)" is set. Set the procedure (6) "Zero-P" after "Complete" is displayed on "State" of the procedure (10). Start point (10) Mechanical basic...
  • Page 497: Basic Position Alignment Method Ii

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.1.2 Basic Position Alignment Method II Preparations #2049 type (absolute position detection type) = 4 Set the parameters on the (marked point alignment method II) [Abs.Posit.Param.] screen. #2059 zerbas (zero return parameter) =0 (position where the axis was stopped) The parameters other than #2049 type can also be set in [Absolute position setting screen].
  • Page 498 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System Move the axis toward the mechanical State: [Origin set] basic position and align it to the marked point. Move the cursor to "Origin-P" with The input value is registered in the "Origin-P" area. State: [Complete] the [ ↑...
  • Page 499: Machine End Stopper Method: Automatic Initialization

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.1.3 Machine End Stopper Method: Automatic Initialization Preparations #2049 type (absolute position detection type) = 1 (stopper method) Set the parameters on the #2054 clpush (current limit) = 0 to 100 [Abs.Posit.Param.] screen.
  • Page 500 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System Move the cursor to "Zero-P" with The input value is registered in the "Zero-P" area. the [ ↑ ] and [ ↓ ] keys.Enter the value in the input area and press the [INPUT] key.
  • Page 501 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System The operation order is slightly different when "#2059 zerbas = 1 (grid point just before stopper)" is set. Set the procedure (6) "Zero-P" after "Complete" is displayed on "State" of the procedure (12). Automatic initialization start point Push speed (10)
  • Page 502 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System (Note7) Automatic initialization cannot be started in the following cases. The operation message "Can't start" will appear if starting is attempted. - When "#0 Absolute posn set" is not set. - When the "#2 Zero-P"...
  • Page 503: Machine End Stopper Method: Manual Initialization

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.1.4 Machine End Stopper Method: Manual Initialization Preparations #2049 type (absolute position detection type) = 1 (stopper method) Set the parameters on the #2054 clpush (current limit) = 0 to 100 [Abs.Posit.Param.] screen.
  • Page 504 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System Move the cursor to "Zero-P" with The input value is registered in the "Zero-P" area. the [ ↑ ] and [ ↓ ] keys. Enter the value in the input area and press the [INPUT] key.
  • Page 505 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System (Note 1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P", and then turn the power OFF and ON. (Note 2) If pressing against the machine end is attempted without passing the grip point once after turning the power ON, the operation message "Not passed on grid"...
  • Page 506: Dog-Type

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.1.5 Dog-type Preparations #2049 type (absolute position detection type) = 3 (dog-type) Set the parameters on the [Abs.Posit.Param.] screen. Turn the power OFF and ON. (Only when "#2049 type" has been reset.) The following are the operations on [Absolute position setting screen].(Select [Mainte] - [To Abs pos]) Select the axis set to type 3 on the [Abs.Posit.Param.] screen.
  • Page 507: Setting The Grid Interval And The Reference Encoder For Grid Interval

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.1.6 Setting the Grid Interval and the Reference Encoder for Grid Interval Set the parameters "#2041 grspcref (reference encoder for grid interval)" and "#2049 grspc (grid interval)" according to the machine configuration.
  • Page 508: Precautions Common For The Dogless-Type Absolute Position Encoder

    (3) When an MPI scale made by Mitsubishi Heavy Industries Machine Tool Co., Ltd. is used, set the zero point return parameters so that Z phase of the MPI scale becomes the grid point (electric basic position), and then perform zero point initialization setting.
  • Page 509: Adjustment Of Reference Position Return In Relative Position Detection System

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.2 Adjustment of Reference Position Return in Relative Position Detection System 22.2.1 Dog-type Reference Position Return Operation In the dog-type reference position return, the axis moves as follows: (1) Starts moving at G28 rapid traverse rate.
  • Page 510: Dog-Type Reference Position Return Adjustment Procedures

    M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System 22.2.2 Dog-type Reference Position Return Adjustment Procedures Adjust the dog-type reference position return with the following steps. (1) Select [Param] menu from the maintenance screen, and then select zero point parameter screen by pressing the page up/down keys.
  • Page 511 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System (5) Determine the grid mask amount according to the state as shown below. Grid space When is smaller Axis speed Electrical zero point (the first grid after the switch is turned ON and OFF) than the grid amount Reference position Position...
  • Page 512 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System (7) Turn the power OFF and ON, and then execute reference position return. (8) Confirm the grid space and grid amount values on DRIVE MONITOR screen. If the grid amount value is approximately half of the grid space, the grid mask amount has been set correctly. If the value is not approximately half, repeat the procedure from step (1).
  • Page 513 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System Grid point The position encoder has a Z-phase that generates one pulse per rotation. The 0-point position of this Z-phase is the grid point. Thus, there is a grid point per rotation of the position encoder, and the machine has many grid points at a regular pitch. The grid point can be set at intervals of grid space by setting the grid space (#2029 grspc).
  • Page 514 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System Reference position return direction (#2030 dir (-)) The direction of the (axis) movement, after the dog-type reference position return is executed and the limit switch kicks the dog and decelerate to stop, is set to either positive "0" or negative "1". Set "0"...
  • Page 515 M800S/M80/E80 Series Connection and Setup Manual 22 Setting the Position Detection System IB-1501269-J...
  • Page 516: Setting The Tool Entry Prohibited Range

    Setting the Tool Entry Prohibited Range IB-1501269-J...
  • Page 517: Stroke End (H/W Ot)

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range Following functions are available for setting a tool entry prohibited range to detect over travels (OT). (1) Stroke end (H/W OT) The limit switch signal will detect the stroke end and limit the movement of the axis. (2) Stored stroke limit (S/W OT) Prohibited ranges are set with parameters.
  • Page 518: Stored Stroke Limit (S/W Ot)

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2 Stored Stroke Limit (S/W OT) 23.2.1 Outline Three tool entry prohibited ranges can be set with stored stroke limit I, stored stroke limit II, IIB and stored stroke limit IB. Part of the prohibited range on the outside of stored stroke limit I can turn into a moveable range with stored stroke limit Set the parameters to select the entry prohibited range, stored stroke limit II or IIB.
  • Page 519 M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range Valid Conditions of Stored Stroke Limit When using the relative position detection system, the stored stroke limit is invalid until the reference position return is completed after the power is turned ON. The stored stroke limit can be validated even if the reference position return is not yet completed, by setting "#2049 type (Absolute position detection method)"...
  • Page 520 M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range The stored stroke limits I, II, IIB, IB and IC are handled as follows. Prohibited Type Description Range setting parameters Validating conditions range - Set by the machine tool builder. "#2013 OT - - Reference position return is - When used with II, the confined range...
  • Page 521: Stored Stroke Limit I

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.2 Stored Stroke Limit I This is a stroke limit function used by the machine tool builder. The boundary is set with the parameters ("#2013 OT - (Soft limit I -)"...
  • Page 522: Stored Stroke Limit Ii

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.3 Stored Stroke Limit II The boundary is set with the axis parameters "#8204 OT-CHECK-N" and "#8205 OT-CHECK-P" or with program commands. Either the inside or the outside of the set boundary is the prohibited range. Whether the inside or outside of the range is prohibited is determined by "#8210 OT-INSIDE".
  • Page 523 M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range (2) Stored stroke limit IIB (When prohibited range is on inside) A range except for that of the stored stroke limit I becomes the movement prohibited range. : Moveable range : Prohibited range (A): Set value for (-) side...
  • Page 524: Stored Stroke Limit Ib

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.4 Stored Stroke Limit IB The boundary is set for each axis with the axis parameters "#2061 OT_1B-" and "#2062 OT_1B+". The inside of the set boundary is the prohibited range. : Moveable range : Prohibited range Point 5: "#2062 OT_1B+ (Soft limit IB+)"...
  • Page 525: Stored Stroke Limit Ic

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.5 Stored Stroke Limit IC The boundary is set for each axis with the axis parameters "#2061 OT_1B-" and "#2062 OT_1B+". The inside of the set boundary is the machine movement valid range. This is valid when the axis parameter "#2063 OT_1Btype (Soft limit IB type)"...
  • Page 526: Movable Range During Inclined Axis Control

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.6 Movable Range during Inclined Axis Control By setting "#2063 OT_1Btype" to "3", the inclined axis control axis can be checked with the program coordinates using the stored stroke limit IB/IC range setting ("#2061" and "#2062"). The stored stroke limit IB and IC cannot be used together at this time.
  • Page 527: Stored Stroke Limit For Rotation Axis

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.7 Stored Stroke Limit for Rotation Axis Stored stroke limits I and II are used as the stored stroke limit for the rotation axis. The area between the maximum and minimum values of the prohibited range's parameters, which does not contain the 0 point of the basic machine coordinate system, is the entry prohibited range.
  • Page 528: Precautions

    M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range 23.2.9 Precautions (1) If the maximum value and minimum value of the stored stroke limit's prohibited range are set to the same value, the following will occur. (a) When the maximum value and minimum value are set to "0", if the outside is the prohibited range, the entire range will be prohibited.
  • Page 529 M800S/M80/E80 Series Connection and Setup Manual 23 Setting the Tool Entry Prohibited Range IB-1501269-J...
  • Page 530: Setting The Machine Error Compensation

    Setting the Machine Error Compensation IB-1501269-J...
  • Page 531: Memory-Type Pitch Error Compensation/Memory-Type Relative Position Error Compensation

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.1 Memory-type Pitch Error Compensation/Memory-type Relative Position Error Compensation 24.1.1 Outline (1) Memory-type pitch error compensation According to the specified parameters, this method compensates an axis feed error caused by a ball screw pitch error, etc.
  • Page 532 M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation (2) Memory-type relative position error compensation This function compensates the relative position error between two orthogonal axes caused by deflection of the moving according to the specified parameters. You can set compensation amount in the compensated axis direction for each division point obtained by equally dividing the machine coordinates of the basic axis.
  • Page 533: Setting Compensation Data

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.1.2 Setting Compensation Data There are two methods for setting the compensation data: absolute amount method and incremental amount method. "#4000 Pinc" 0 : Absolute amount method 1 : Incremental amount method (1) Absolute amount method When you feed an axis from the reference position to each division point, calculate and set the compensation amount using the following formula.
  • Page 534 M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation (2) Incremental amount method The compensation amount at the division point "n" is calculated for the axis that moves by "interval between division points" specified with #4007. The formula for calculating the compensation amount differs depending on whether the division point "n"...
  • Page 535: Setting Method

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.1.3 Setting Method 24.1.3.1 Using a Linear Axis as Basic Axis (1) When "mdvno" or "pdvno" exists at both ends of "rdvno" Compensation ( - 3) ( - 2) amount Error in incremental...
  • Page 536 M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation (3) When the range compensated is only the negative range Compensation ( - 1) ( - 3) amount in incremental Error amount method #4125 #4126 #4127 #4128 #4129 #4130 Basic axis machine...
  • Page 537: Using A Rotary Axis As Basic Axis

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.1.3.2 Using a Rotary Axis as Basic Axis Compensation ( - 2) ( - 3) amount in incremental #4123 #4124 #4125 #4126 #4127 #4128 amount method Error 360 deg Basic axis machine coordinate ( - 2)
  • Page 538: Bidirectional Pitch Error Compensation

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.2 Bidirectional pitch error compensation 24.2.1 Outline Compensation amounts can be set respectively for the movement in positive and negative directions, and compensation can be made for each direction. This method will reduce the difference between the path in the positive direction and path in the negative direction.
  • Page 539: Setting Method

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.2.2 Setting Method 24.2.2.1 When the basic axis is a linear axis This section describes how to set bidirectional pitch error data by taking the linear axis having a pitch error such as illustrated below as an example.
  • Page 540 M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation Setting parameters (1) Set setting method for compensation amount to "#4000 Pinc". #4000 Setting method setting value This method sets the difference between the commanded position and the actual machine position of each (absolute amount division point as the compensation amount.
  • Page 541 M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation Setting pitch error compensation data (1) Move the axis to positive or negative direction, then measure and record actual machine position of each division point. Calculate compensation amount for each division point based on the actual machine position. #4000 Calculation method of compensation amount (*1) setting value...
  • Page 542: When The Basic Axis Is A Rotary Axis

    M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation 24.2.2.2 When the basic axis is a rotary axis This section describes how to set bidirectional pitch error data by taking a rotary axis having a pitch error such as illustrated below as an example.
  • Page 543 M800S/M80/E80 Series Connection and Setup Manual 24 Setting the Machine Error Compensation IB-1501269-J...
  • Page 544: Setting The Position Switches

    Setting the Position Switches IB-1501269-J...
  • Page 545: Outline

    M800S/M80/E80 Series Connection and Setup Manual 25 Setting the Position Switches 25.1 Outline Position switches (PSW) are used as alternatives for the dog switches provided on the machine axis. Virtual dog switches can be used by specifying axis names and conditions of virtual dog positions. This function outputs a signal to the PLC interface when the machine reaches the specified area.
  • Page 546: Setting And Operation Examples Of Dog1 And Dog2

    M800S/M80/E80 Series Connection and Setup Manual 25 Setting the Position Switches 25.2 Setting and Operation Examples of dog1 and dog2 Settings of dog1 and dog2 Positions of dog1 and dog2 Description A signal is output when the Basic machine coordinate dog1 dog2 dog1 <...
  • Page 547: Canceling The Position Switch

    M800S/M80/E80 Series Connection and Setup Manual 25 Setting the Position Switches 25.3 Canceling the Position Switch Enter a position switch number to be canceled (#75*1) in "# ( )" and a slash in "DATA ( )" on the setting field, then press the [INPUT] key.
  • Page 548: Setting The Backlash Compensation

    Setting the Backlash Compensation IB-1501269-J...
  • Page 549: Backlash Compensation

    M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation 26.1 Backlash Compensation Travel amount of a machine table may become less than the commanded amount due to the error (backlash) caused by reversal of the direction of the axis. The backlash compensation is a function which automatically adds compensation amount to the travel amount when the direction of the axis is reversed.
  • Page 550: Backlash Compensation Ii

    M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation 26.2 Backlash Compensation II This function reduces quadrant error caused by the backlash when the traversing direction is reversed in machines where semi-closed loop control is implemented. Acceleration rate at axis direction reversal varies depending on the change of circular radius and commanded speed at machining.
  • Page 551: Enabling Conditions For Backlash Compensation Ii

    M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation 26.2.1 Enabling Conditions for Backlash Compensation II Backlash compensation II is enabled when all the following conditions are satisfied. (1) Backlash compensation II option is ON. (2) Parameter "#14360 valBL2" (backlash compensation II valid) is ON. (3) Parameter "#14361 BL2_a1"...
  • Page 552: Setting Compensation Amount Of Backlash Compensation Ii

    M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation 26.2.2.2 Setting compensation amount of backlash compensation II For the backlash compensation II compensation amount, set the size of projection which is generated at axis direction reversal. For the unit of compensation amount, follow the setting of "#1006 mcmpunit" (Machine error compensation unit). Backlash compensation II compensation amount 1: "#14362 BL2_c1"...
  • Page 553: Precautions For Setting Parameters

    M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation 26.2.2.3 Precautions for setting parameters For the backlash compensation II acceleration rates, set a value greater than "0" from acceleration rate 1 to 4 in ascending order. Parameters are enabled when the backlash compensation II acceleration rates are set in ascending order. The following describes the relationship between setting patterns and parameters to be enabled.
  • Page 554 M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation (2) When the acceleration rate 1 is set to "0" Backlash compensation II is disabled. Quadrant projection compensation is not performed on the axis, and the compensation amount is handled as "0". Compensation amount Compensation amount 1...
  • Page 555 M800S/M80/E80 Series Connection and Setup Manual 26 Setting the Backlash Compensation (4) When consecutive acceleration rates are set to the same value Ascending order in acceleration rate setting refers to the case where subsequent values become greater than the previous ones. Therefore, as same as (3), when the acceleration rates are no longer arranged in ascending order, corresponding parameters are disabled;...
  • Page 556: Confirming The Spindle Operation

    Confirming the Spindle Operation IB-1501269-J...
  • Page 557: In Manual Operation (With Manual Numerical Command)

    M800S/M80/E80 Series Connection and Setup Manual 27 Confirming the Spindle Operation Confirm that the spindle operates properly in manual/MDI operation. Confirm the spindle rotation speed as well. CAUTION 1. Do not adjust the spindle when possible risks associated with adjustment procedures are not thoroughly taken into consideration.
  • Page 558: In Mdi Operation

    M800S/M80/E80 Series Connection and Setup Manual 27 Confirming the Spindle Operation 27.2 In MDI Operation (1) Select MDI mode. (2) Select [MDI] on the Setup screen. Enter a program to issue an S command. Program example (to rotate the spindle at 100r/min for 5 seconds) S100 M03 ;...
  • Page 559 M800S/M80/E80 Series Connection and Setup Manual 27 Confirming the Spindle Operation IB-1501269-J...
  • Page 560: Setting The Handy Terminal

    Setting the Handy Terminal IB-1501269-J...
  • Page 561: Inputting The Data From A Personal Computer

    M800S/M80/E80 Series Connection and Setup Manual 28 Setting the Handy Terminal It is necessary to customize the display part composition, the key input, the communication condition with NC, etc. to connect the handy terminal (HG1T-SB12UH-MK1346-L*). Create the customized data with "NC Designer HT" and download it to the handy terminal. There are two methods to input customized data for the handy terminal.
  • Page 562 M800S/M80/E80 Series Connection and Setup Manual 28 Setting the Handy Terminal (3) Select [Online] - [Communication setting] from the menu of "NC Designer HT" and confirm the communication condition is as follows. Port: Personal computer port Transmission: 19200 [bps] Data length: 8 [bit] Stop bit: 2 Parity: None (4) Select [Online] - [Download] from the menu of "NC Designer HT".
  • Page 563 M800S/M80/E80 Series Connection and Setup Manual 28 Setting the Handy Terminal (7) The customized data will be downloaded to the handy terminal. (8) When the download has been completed, the following dialog box will be displayed. IB-1501269-J...
  • Page 564: Inputting The Data From Nc

    M800S/M80/E80 Series Connection and Setup Manual 28 Setting the Handy Terminal 28.2 Inputting the Data from NC Create a download data (handy.cod) from a project data (*.p1t) created with "NC Designer HT", then download it to the handy terminal. (1) Start the customized data creation tool "NC Designer HT" to create a project data (*.p1t). (2) Select [File] - [Writing download data] from the menu of "NC Designer HT"...
  • Page 565 M800S/M80/E80 Series Connection and Setup Manual 28 Setting the Handy Terminal Operating status is displayed by the LED on the control unit. Lo ... Loading En ... Complete without error n1 - n7 ... Complete with error When the download is completed with error, possible causes are as listed below. Take measures and then perform the download procedure again.
  • Page 566: Setting The Deceleration Check

    Setting the Deceleration Check IB-1501269-J...
  • Page 567: Function

    M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check 29.1 Function The next block is executed after the axis is decelerated and stopped at the joint between the axis movement blocks. This is to reduce the machine shock and to prevent the corner roundness, at the time when the sudden change of the control axis feedrate occurs.
  • Page 568 M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check (b) Selecting the deceleration check method There are three methods for the deceleration check, and the method is selected by the parameter. 1) For the execution block with the rapid traverse command (G00/G53) Parameter Deceleration check method Determination condition...
  • Page 569: Deceleration Check Method

    M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check 29.2 Deceleration Check Method (1) Command deceleration check After interpolation for one block has been completed, the completion of the command system deceleration is confirmed before execution of the next block. The required time for the deceleration check is equal to the longest one of the deceleration check time for the simultaneously commanded axes, which are determined according to the acceleration/deceleration mode and time constant.
  • Page 570 M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check (2) Smoothing check method After the command deceleration check has been completed, the completion of all axes smoothing zero in the part system is confirmed before execution of the next block. (Example) For exponential acceleration/deceleration Command Execution block...
  • Page 571: Deceleration Check For Opposite Direction Movement Reversal

    M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check 29.3 Deceleration Check for Opposite Direction Movement Reversal Deceleration check cannot be designated for G01 -> G00 or G01 -> G01, but it can be designated in the following manner only when the movement reverses to the opposite direction in successive blocks.
  • Page 572: Parameter

    M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check 29.4 Parameter (1) Designating deceleration check Base specification parameter Item Details Setting range The definitions are changed with the setting of "#1306 InpsTyp 1193 inpos Deceleration check specification type". When Select the deceleration check method for G0.
  • Page 573 M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check (3) Designation of in-position check width (a) Servo parameter Item Details Setting range Set the in-position detection width. Set the accuracy required for the machine. SV024 In-position The lower the setting is, the higher the positioning 2224 0 to 32767 (μm) detection width...
  • Page 574: Relation With Other Functions

    M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check 29.5 Relation with Other Functions (1) Tool compensation When the tool compensation is performed, the deceleration check will be operated on the block after compensation. (2) Control axis synchronization (G125), control axis superimposition (G126), arbitrary axis exchange (G140), arbitrary axis superimposition (G156) When control axis synchronization (G125), control axis superimposition (G126), arbitrary axis exchange (G140) or arbitrary axis superimposition (G156) is performed in the other part system, the succeeding block start timing may...
  • Page 575: Precautions

    M800S/M80/E80 Series Connection and Setup Manual 29 Setting the Deceleration Check 29.6 Precautions (1) When in-position check is valid, set the servo in-position width of the servo parameter. (2) This function is invalid for the axes in the automatic machine lock. (3) When the MSTB is commanded to the next block of the cutting commanded block, the MSTB code is output before the completion of the cutting command deceleration.
  • Page 576: Adjust S-Analog Screen

    Adjust S-analog Screen IB-1501269-J...
  • Page 577 M800S/M80/E80 Series Connection and Setup Manual 30 Adjust S-analog Screen The spindle analog output adjustment is carried out on this screen. Display items Display item Details This is a number to be used when inputting/outputting the parameters. For manual adjustments, this uses the [ ↑ ] [ ↓ ] keys to move the cursor to the setting item Parameter No.
  • Page 578: Adjustment Preparations

    M800S/M80/E80 Series Connection and Setup Manual 30 Adjust S-analog Screen 30.1 Adjustment Preparations The PLC must be stopped when performing spindle analog output adjustments by one of the following methods below: Operation methods (when stopping the PLC with the rotary switch) Set the rotary switch in the upper part of the unit to The PLC is stopped.
  • Page 579: Performing Manual Adjustments

    M800S/M80/E80 Series Connection and Setup Manual 30 Adjust S-analog Screen 30.3 Performing Manual Adjustments Adjusting the ch0 0V offset Use the [ ↑ ] [ ↓ ] keys to move the cursor to item The current setting value is displayed at "Current adjust data". "#10101", then press the [Manual adjust]menu A 0V analog voltage is output to ch0 at this time.
  • Page 580 M800S/M80/E80 Series Connection and Setup Manual 30 Adjust S-analog Screen Adjusting the ch0 - gain The current setting value is displayed at "Current adjust data". Use the [ ↑ ] [ ↓ ] keys to move the cursor to item A ch0 -10V analog voltage is output at this time.
  • Page 581 M800S/M80/E80 Series Connection and Setup Manual 30 Adjust S-analog Screen IB-1501269-J...
  • Page 582: Device Open Parameter Screen

    Device Open Parameter Screen IB-1501269-J...
  • Page 583 M800S/M80/E80 Series Connection and Setup Manual 31 Device Open Parameter Screen This function can set or change the user back up area of the PLC device from the NC screen. Divide the device area in accordance with the specifications of the machine tool builder and switch the display format or data type for each divided area (hereinafter called a group information).
  • Page 584 M800S/M80/E80 Series Connection and Setup Manual 31 Device Open Parameter Screen Display items Display items Details Setting range Parameter No. Display the parameter No.(maximum of 100). Set the head device which designates the divided area. - It is possible to designate the device allocation which overlaps with R8300 to R9799 other groups.
  • Page 585 M800S/M80/E80 Series Connection and Setup Manual 31 Device Open Parameter Screen Display items Details Setting range Designate the display format of the data, the restriction of display, and the state of input protection. a) Cancellation of input protection 1: Not check Input protection check for the data protection key 2 will not be executed in the group detail screen.
  • Page 586 M800S/M80/E80 Series Connection and Setup Manual 31 Device Open Parameter Screen Menu for the device allocation/number of data input Menu Details Line Copy the data of a line where a cursor is placed. copy Writes the contents of the data copied (one line) into a line where the cursor is placed. If the data of the line is changed after the [Line copy] is pressed, the data before change will be written when Line paste...
  • Page 587 M800S/M80/E80 Series Connection and Setup Manual 31 Device Open Parameter Screen Menu for inputting the data type Menu Details Input "BYTE" to the data type. BYTE When the display format is BIT format, it will be changed to the desimal format with sign. Input "WORD"...
  • Page 588: Sram Open Parameter Screen

    SRAM Open Parameter Screen IB-1501269-J...
  • Page 589 M800S/M80/E80 Series Connection and Setup Manual 32 SRAM Open Parameter Screen SRAM open area for a machine tool builder can be set or changed. It can be divided according to the machine tool builder's usage, and the display format and the data format can be switched for each divided area (hereinafter called a group).
  • Page 590 M800S/M80/E80 Series Connection and Setup Manual 32 SRAM Open Parameter Screen Display items Display item Details Setting range Display the parameter No.(maximum of 100). Set the data type (CHAR, SHORT, LONG, DOUBLE) of the allocation area. CHAR: 1-byte integer type. The area is saved per 1-byte. SHORT: 2-byte integer type.
  • Page 591 M800S/M80/E80 Series Connection and Setup Manual 32 SRAM Open Parameter Screen Display item Details Setting range Designate the display format of the data, display limitation and the state of the input protection. a) Cancellation of input protection 1: Not check Input protection check for the data protection key 2 will not be executed in the group detail screen.
  • Page 592 M800S/M80/E80 Series Connection and Setup Manual 32 SRAM Open Parameter Screen Menu when inputting the data type Menu Details Input CHAR into the data type. CHAR Input SHORT into the data type. SHORT Input LONG into the data type. LONG Input DOUBLE into the data type.
  • Page 593 M800S/M80/E80 Series Connection and Setup Manual 32 SRAM Open Parameter Screen Menu when inputting the display format Menu Details W/ DEC Change the display format to the decimal format with sign. sign W/O DEC Change the display format to the decimal format without sign. sign Change the display format to the hexadecimal format.
  • Page 594: Data Backup And Restoration

    Data Backup and Restoration IB-1501269-J...
  • Page 595 M800S/M80/E80 Series Connection and Setup Manual 33 Data Backup and Restoration The following two functions are available for the data backup and restoration: all backup function for files in batch and input/output function for separate files. The following devices are available in all backup and restoration. Memory card (Front-side SD card) DS (Back-side SD card of display unit) USB memory...
  • Page 596: All Backup

    M800S/M80/E80 Series Connection and Setup Manual 33 Data Backup and Restoration 33.1 All Backup The following explains the procedure to backup the various NC data to the memory card in a batch. [Note] (1) APLC data can be backed up only when the APLC release specification is valid. Operation method Press the menu [Backup].
  • Page 597 M800S/M80/E80 Series Connection and Setup Manual 33 Data Backup and Restoration The backup is completed without error. The states of backup-complete files turn to "Complete", the date displayed in "Backup list" will be updated. <Note> - If the APLC release specification is invalid, the APLC data cannot be backed up and "Unexecute"...
  • Page 598: All Restoration

    M800S/M80/E80 Series Connection and Setup Manual 33 Data Backup and Restoration 33.2 All Restoration The following explains the procedure to restore the various NC data backed up to memory card in a batch. The files which has been automatically backed up can be restored only when the device set by the parameter "#8919 Auto backup device"...
  • Page 599 M800S/M80/E80 Series Connection and Setup Manual 33 Data Backup and Restoration Move the cursor to select the file. Press the The operation message "OK? (Y/N)" appears. [INPUT] key. The cursor moves as follows: <Note> [ ↓ ] key: - If there are no files at the position where the cursor moved Auto1 ->...
  • Page 600: Appx.1: Setting The System Lock

    Appx.1: Setting the System Lock IB-1501269-J...
  • Page 601: Setting The Encryption Key

    M800S/M80/E80 Series Connection and Setup Manual 34 Appx.1: Setting the System Lock System lock is a function for a machine tool builder to set a valid term to use the machine that machine user is using. If a decryption code is not input by a specified limit, the servo ready finish signal will be forcibly turned OFF and the use of the machine will be disabled.
  • Page 602: Setting Of Expiration Date

    M800S/M80/E80 Series Connection and Setup Manual 34 Appx.1: Setting the System Lock 34.2 Setting of Expiration Date Inputting a decryption code while the system lock is disabled, the system lock function becomes enabled and the expiration date is being set. While the system lock is enabled, the date and time of the CNC cannot be set to a past date and time.
  • Page 603: Display Of Time Limit Warning And Alarm Notification

    M800S/M80/E80 Series Connection and Setup Manual 34 Appx.1: Setting the System Lock 34.3 Display of Time Limit Warning and Alarm Notification (1) As the expiration date approaches, the warning "Z64 Valid term soon to be expired" appears at the bottom right of the screen.
  • Page 604: Appx.2: Protection Setting

    Appx.2: Protection Setting IB-1501269-J...
  • Page 605: Protect Setting Screen

    M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting Operating the maintenance screen reduces a phenomenon in which defective workpieces run out due to an operation mistake, by implementing a restriction with seven operation levels. The operation level varies depending on the MTB specifications.
  • Page 606 M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting Data to be protected Initial value Setting range Display items Objects to be protected Change Output Change Output Change Output Table for protection level setting on this screen Available level Table for protection level setting cannot be changed by the ○...
  • Page 607 M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting Initial value Setting range Display items Objects to be protected Change Output Change Output Change Output Automatic backup (Output) Batch backups (menu [Backup]) ○ Batch backups (menu [Master Backup]) Batch backups (menu [Restore]) Batch backups (menu [Master Restore]) HMI environment setting Memory format...
  • Page 608: Returning The Password To The Non-Input State (Operation Level 0 To 3)

    M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting (Note 5) Following operations are available to operate at the protection level 6 and over. - Modal output, one-shot output and modal clear - PLC-STOP - S analog adjustment - Absolute position setting - Servo diagnosis - Collection setting - HMI ending...
  • Page 609: Changing The Password

    M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting 35.4 Changing the Password Operation Methods (Example) Change the password of operation level 4 from "OLDPASS" to "NEWPASS" Press the menu [Change pasword]. The menu [Change pasword] is highlighted. The operation message "Enter the current password." is displayed.
  • Page 610: Clearing The Password

    M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting 35.5 Clearing the Password Operation Methods (Example) Clear the password of operation level 4 Press the menu [Change pasword]. The menu [Change pasword] is highlighted. The operation message "Enter the current password." is displayed.
  • Page 611: Changing The Protection Level

    M800S/M80/E80 Series Connection and Setup Manual 35 Appx.2: Protection Setting 35.6 Changing the Protection Level Changing the protection level is available only for the data being set in the lower level than a current operation level. Operation Methods (Example) Change the "Available level" from "4" to "5" Press the menu [Setup pro lev].
  • Page 612: Appx.3: Displaying Original Logo On Standard Screen

    Appx.3: Displaying Original Logo On Standard Screen IB-1501269-J...
  • Page 613 M800S/M80/E80 Series Connection and Setup Manual 36 Appx.3: Displaying Original Logo On Standard Screen A logo that machine tool builders create can be displayed on the upper left of the standard screen. In order to display the logo, create a logo file (JPG) and install it. When a logo file is prepared by machine tool builders, the unit name (Base common parameter #1135 unt_nm) is not displayed.
  • Page 614: Appx.4: Emc Installation Guidelines

    Appx.4: EMC Installation Guidelines IB-1501269-J...
  • Page 615: Introduction

    (3) Introduction of members for measures Mitsubishi is carrying out tests to confirm the compliance to the EMC Directives under the environment described in this manual. However, the level of the noise will differ according to the equipment type and layout, control panel structure and wiring lead-in, etc.
  • Page 616: Emc Measures

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.3 EMC Measures The main items relating to EMC measures include the following. (1) Store the device in a sealed metal panel. (2) Ground all conductors that are floating electrically. Decrease the impedance. (3) Increase the distance between the drive line and signal wire.
  • Page 617: Measures For Door

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.4.2 Measures for Door (1) Use metal for all members configuring the panel. (2) When joining the door, use a gasket to lower the impedance of the contacting sections, or use a structure with a large contact area as shown below.
  • Page 618: Measures For Wiring In Panel

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.5 Measures for Wiring in Panel Cables act as antennas to propagate unnecessary noise, and thus must be appropriately shielded and treated. The following measures must be sufficiently considered for the cables (J210/J303) that carry out high-speed communication.
  • Page 619: Shield Treatment Of Cables

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.5.2 Shield Treatment of Cables Use shielded cables for the cables wired outside the panel. Use a shield clamp within 10cm of the lead-out port from the panel. (Refer to "EMC Countermeasure Parts: Shield Clamp Fitting".) (1) DC power supply cable [J070/J071 cable] Shield clamp...
  • Page 620: Emc Countermeasure Parts

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.6 EMC Countermeasure Parts 37.6.1 Shield Clamp Fitting The effect can be improved by directly connecting the cable's shield sheath to the grounding plate as shown below. Install the grounding plate near the outlet (within 10cm) of each panel, and press against the grounding plate with the clamp fitting.
  • Page 621: Ferrite Core

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.6.2 Ferrite Core The ferrite core is mounted integrally with the plastic case. This can be installed with one touch without cutting the interface cable or power supply cable. This ferrite core is effective against common mode noise, allowing measures against noise without affecting the quality of the signal.
  • Page 622: Surge Absorber

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.6.3 Surge Absorber Make sure that the surge does not directly enter the AC line of the general-purpose stabilized power supply (user- prepared) supplying power to the control unit and DIO. Select the following product or equivalent for the surge absorber. Refer to the manufacturer catalog for detailed characteristics, outline and connection methods of the surge absorber.
  • Page 623 M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines (2) Example of surge absorber installation An example of installing the surge absorber in the machine control panel is shown below. A short-circuit fault will occur in the surge absorber if a surge exceeding the tolerance is applied. Thus, install a circuit protection breaker in the stage before the surge absorber.
  • Page 624: Selection Of Stabilized Power Supply

    M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines 37.6.4 Selection of Stabilized Power Supply Consider the following characteristics when selecting the stabilized power supply (prepared by machine manufacturer). Use a power supply that complies with CE Marking or that follows the safety standards given below. Stabilized power supply selection items Item Standard setting...
  • Page 625 M800S/M80/E80 Series Connection and Setup Manual 37 Appx.4: EMC Installation Guidelines IB-1501269-J...
  • Page 626: Appx.5: Restrictions For Lithium Batteries

    Appx.5: Restrictions for Lithium Batteries IB-1501269-J...
  • Page 627: Restriction For Packing

    RID, ADR 38.1.1 Target Products The following Mitsubishi NC products use lithium batteries. If the lithium metal content exceeds 1g for battery cell and 2g for battery, the battery is classified as dangerous good (Class9). In order to avoid an accidental actuation during the transportation, all lithium battery products incorporated in a machinery or device must be fixed securely and must be shipped with wrapped over the outer package as to prevent damage or short- circuits.
  • Page 628: Handling By User

    M800S/M80/E80 Series Connection and Setup Manual 38 Appx.5: Restrictions for Lithium Batteries 38.1.2 Handling by User The shipper must confirm the latest IATA Dangerous Goods Regulations, IMDG Codes and laws and orders of the corresponding export country. These should be checked by the company commissioned for the actual transportation. IATA: International Air Transport Association http://www.iata.org/ IMDG Code: A uniform international code for the transport of dangerous goods by seas determined by IMO (International...
  • Page 629: Products Information Data Sheet (Er Battery)

    This description is based on the lithium battery's (ER battery) hazardous goods data sheet (Products Information Data Sheet) which MITSUBISHI has researched, and will be applied only to the ER batteries described in "Transportation Restrictions for Lithium Batteries: Restriction for Packing".
  • Page 630 M800S/M80/E80 Series Connection and Setup Manual 38 Appx.5: Restrictions for Lithium Batteries (6) Physical/chemical properties Physical form Solid Shape Cylinder type Smell Odorless Not applicable (insoluble) Appearance Boiling point/Boiling range, Melting point, No information Decomposition temperature, Flash point (7) Stability and reactivity Stability Stable under normal handling condition.
  • Page 631: Forbiddance Of Transporting Lithium Battery By Passenger Aircraft Provided In The Code Of Federal Regulation

    M800S/M80/E80 Series Connection and Setup Manual 38 Appx.5: Restrictions for Lithium Batteries 38.3 Forbiddance of Transporting Lithium Battery by Passenger Aircraft Provided in the Code of Federal Regulation This regulation became effective from Dec.29, 2004. This law is a domestic law of the United States, however it also applies to the domestic flight and international flight departing from or arriving in the United States.
  • Page 632: Restriction Related To Eu Battery Directive

    Follow the instruction bellow as shipping products incorporating MITSUBISHI device. (1) When shipping products incorporating MITSUBISHI device any time later than September 26th, 2008, the symbol mark shown as Figure 1 in section "Information for End-user" is required to be attached on the machinery or on the package.
  • Page 633 M800S/M80/E80 Series Connection and Setup Manual 38 Appx.5: Restrictions for Lithium Batteries IB-1501269-J...
  • Page 634: Appx.6: Precautions For Compliance To Ul/C-Ul Standards

    Appx.6: Precautions for Compliance to UL/c-UL Standards IB-1501269-J...
  • Page 635 M800S/M80/E80 Series Connection and Setup Manual 39 Appx.6: Precautions for Compliance to UL/c-UL Standards (1) Selection of external 24VDC power supply unit (The unit shall be prepared by the machine tool builder.) This NC system complies with the UL Standards on the condition that the stabilized power supply unit supplying 24VDC to each unit is a UL-approved part of SELV/limited power LPS or Class 2.
  • Page 636 4.7.4 Keyboard for 10.4-type Display Unit (FCU8-KB041) 4.7.7 Keyboard for 10.4-type Display Unit (FCU8-KB048) 4.10 Function Expansion Unit 4.11.2 PROFIBUS-DP (FCU8-EX563) 4.14 Exclusive SD cards for MITSUBISHI CNC 5.3.5 Function Expansion Unit 7.11.2 Connecting I/O Device via PROFIBUS-DP 10.9 Connecting with Analog I/O Signal (FCU8-DX202) 13.2.12 J221 Cable...
  • Page 637 Date of Manual No. Revision details revision Apr.2016 IB(NA)1501269-C (Continued from the previous page) - Chapter composition change Title of chapter 6 was changed into "Precautions for Connecting" Former 6.3 to 6.9 were changed into independent chapters (Chapter 7 to 12) Explanations for connection of drive unit in former 9.3 to 9.5 were moved to a new chapter 7 Former chapter numbers 7 to 19 were changed into 13 to 24 due to the change of...
  • Page 638 4.16 Thermistor 5.3.7 MITSUBISHI CNC Machine Operation Panel 7.11.3 Connecting I/O Device via EtherNet/IP 10.10 Connecting with Thermistor (FCU8-DX408) Chapter 13 Connection of MITSUBISHI CNC Machine Operation Panel Chapter 14 Connection of Handy Terminal 15.2.2 G071 Cable 15.2.4 G430 Cable 15.2.5 G460 Cable...
  • Page 639 Nov. 2017 IB(NA)1501269-F The descriptions of M800 Series/M80 Series were revised in response to S/W version - The following units were added. FCU8-KB922 (MITSUBISHI CNC Machine operation panel) FCU8-KB924 (MITSUBISHI CNC Machine operation panel) - The following cable was deleted.
  • Page 640 Date of Manual No. Revision details revision Mar. 2018 IB(NA)1501269-G The descriptions were revised in response to MITSUBISHI CNC E80 Series. - The following units were added. FCU8-MU513 (Control unit) FCU8-MU514 (Control unit) FCU8-DU121-13 (Display unit) FCU8-KB024 (Keyboard unit) FCU8-KB025 (Keyboard unit)
  • Page 641 5.3.2 Keyboard Unit 5.3.3 Operation Panel I/O Unit 5.3.4 Remote I/O Unit 5.3.6 Communication Expansion Unit 5.3.7 MITSUBISHI CNC Machine Operation Panel 7.1 Machine Operation Panel Connection System Drawing 7.6.2 Connecting with Drive Unit MDS-EM/EMH Series 7.9.1 Handle Numbers 7.11 Connecting I/O Device via Communication Expansion Unit 7.11.4 Connecting I/O Device via EtherNet/IP...
  • Page 642 Date of Manual No. Revision details revision Mar. 2019 IB(NA)1501269-H The descriptions of M800 Series/M80 Series/E80 Series were revised in response to S/W version E0. - The following chapters and sections were added. 7.6.1.2 Drive Unit Arrangement - The following chapter titles were added. 7.6.1.1 Connection of Optical Communication Cables Due to addition of section 7.6.1.2, only the chapter title was added.
  • Page 643 Date of Manual No. Revision details revision Sep. 2019 IB(NA)1501269-J The descriptions of M800 Series/M80 Series/E80 Series were revised in response to S/W version E1. - The following units were added. FCU8-DX834 (Operation panel I/O unit) FCU8-EX568 (FL-net expansion unit) - The following cable was added.
  • Page 644 Date of Manual No. Revision details revision Sep. 2019 IB(NA)1501269-J (Continued from the previous page) 5.3.3 Operation Panel I/O Unit 5.3.6 Communication Expansion Unit 7.1 Control Unit Connection System Drawing 7.3 Connecting with Emergency Stop Signal 7.4 Connecting with Operation Panel I/O Unit 7.5 Connecting with Remote I/O Unit 7.12 Connecting I/O Device via Communication Expansion Unit 9.1 Operation Panel I/O Unit Connection System Drawing...
  • Page 645 TEL: +420-59-5691-185 / FAX: +420-59-5691-199 Russia Service Center BRAZIL MITSUBISHI ELECTRIC RUSSIA LLC MITSUBISHI ELECTRIC DO BRASIL COMÉRCIO E SERVIÇOS LTDA. LETNIKOVSKAYA STREET 2, BLD.1, 5TH 115114 MOSCOW, RUSSIA Votorantim Office TEL: +7-495-721-2070 / FAX: +7-495-721-2071 AV. GISELE CONSTANTINO,1578, PARQUE BELA VISTA, VOTORANTIM-SP, BRAZIL CEP:18.110-650...
  • Page 646 MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD. (CHINA FA CENTER) Singapore Service Center China Shanghai Service Center 307 ALEXANDRA ROAD #05-01/02 MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 1-3,5-10,18-23/F, NO.1386 HONG QIAO ROAD, CHANG NING QU, TEL: +65-6473-2308 / FAX: +65-6476-7439 SHANGHAI 200336, CHINA...
  • Page 647 Every effort has been made to keep up with software and hardware revisions in the contents described in this manual. However, please understand that in some unavoidable cases simultaneous revision is not possible. Please contact your Mitsubishi Electric dealer with any questions or comments regarding the use of this product.

This manual is also suitable for:

M80 seriesE80 seriesM80w series

Table of Contents