(2) Detector type related parameters
Standard specifications
No.
Abbrev.
Parameter name
SV025
MTYP* Motor/Detector type
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.
3. Setup
8
Set the detector type.
9
Set the position detector type for "pen", and the speed detector type
ent
for "ent". In the case of the semi-closed loop control, set the same
A
value for "pen" and "ent".
B
pen
C
ent setting
setting
D
0
0
pen
E
1
1
F
2
2
3
3
4
Setting impossible OHE25K-ET, OSE104-ET
5
Setting impossible OHA25K-ET, OSA104-ET
6
Setting impossible OSE105-ET, OSA105-ET
7
Setting impossible
8
Setting impossible
9
Setting impossible
A
Setting impossible AT342 (Mitsutoyo)
B
Setting impossible
C
(Current
C
synchronization)
D
Setting impossible
E
Setting impossible
F
Setting impossible
3 - 29
Explanation
Detector model name
OSE104
OSA104
OSE105, OSA105
Relative position detection scale, MP type
(Mitsubishi Heavy Industries)
AT41 (Mitsutoyo), FME type, FLE type
(Futaba)
The setting of the slave axis in the speed/current
synchronization control.
When the master axis is the semi-closed control.