Power supply alarm
LED
No.
Alarm name
display
60
Instantaneous power failure
61
Power module overcurrent
62
Frequency error
63
Auxiliary regeneration error
65
Rush relay error
67
Phase failure
68
Watch dog
69
Ground fault
6A
External contactor melting
6B
Rush relay melted
6C
Main circuit error
6D
Parameter error
6E
Memory error
6F
Power supply error
71
Instantaneous power failure/
external emergency stop
73
Over-regeneration
74
Regenerative resistor
overheat
75
Overvoltage
76
External emergency stop
setting error
77
Power module overheat
(Note 1) If a power supply alarm (60 to 77) occurs, all servos will stop with the dynamic brakes.
(Note 2) CV indicates an alarm that occurs with the MDS-C1-CV unit, and CR indicates an alarm that occurs with the MDS-A-CR
unit.
(Note 3) "b", "C" and "d" displayed on the power supply unit's LED as a solid light (not flickering) do not indicate an alarm.
6. Troubleshooting
CV CR
A drop in the 24VDC power was detected.
The power module's overcurrent protection function activated.
The input power frequency exceeded the specified range.
The auxiliary regenerative transistor is still ON.
The rush resistance short-circuit relay does not turn ON.
There is a phase failure in the input power.
The system is not operating normally.
The motor power cable is contacting FG (ground).
The external contactor's contact has melted.
The rush resistance short-circuit relay does not turn OFF.
An abnormality was detected in the main circuit capacitor's charging
operation.
The power supply unit's capacity is not appropriate for the regenerative
resistor type set with the parameters.
An error was detected in the internal memory.
The power supply is not connected, or an error was detected in the
power supply's A/D converter.
This is detected simultaneously if another power supply alarm occurs.
An instantaneous power failure occurred.
The over-regeneration detection level exceeded 100%. The
regenerative resistor is in the overload state.
The temperature protection function in the regenerative resistor
activated.
The main circuit PN bus voltage exceeded the tolerable value.
The rotary switch setting for the external emergency stop does not
match the parameter setting.
The power module's temperature protection function activated.
6 - 8