Cable Stress - Mitsubishi MELDAS MDS-C1 Instruction Manual

Ac servo/spindle
Table of Contents

Advertisement

1-1-6 Cable stress

<1> Sufficiently consider the cable clamping method so that bending stress and the stress from the
cable's own weight is not applied on the cable connection part.
<2> In applications where the servomotor moves, make sure that excessive stress is not applied on the
cable.
If the detector cable and servomotor wiring are stored in a cable bear and the servomotor moves,
make sure that the cable bending part is within the range of the optional detector cable.
Fix the detector cable and power cable enclosed with the servomotor.
<3> Make sure that the cable sheathes will not be cut by sharp cutting chips, worn by contacting the
machine corners, or stepped on by workers or vehicles.
The bending life of the detector cable is as shown below. Regard this with a slight allowance. If the
servomotor/spindle motor is installed on a machine that moves, make the bending radius as large
as possible.
(Mitsubishi optional detector cable and wire material: A14B2343)
Note: The values in this graph are calculated values and are not guaranteed.
1. Installation
8
1 10
7
5 10
7
2 10
7
1 10
6
5 10
6
2 10
6
1 10
5
5 10
5
2 10
5
1 10
4
7
10
4
5 10
4
3 10
Detector cable bending life
20
40
70
100
Bending radius (mm)
1 - 7
200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents