1-1 Installation of servomotor

CAUTION

1-1-1 Environmental conditions

Environment
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Altitude
Vibration
1. Installation
1. Do not hold the cables, axis or detector when transporting the motor. Failure to
observe this could lead to faults or injuries.
2. Securely fix the motor to the machine. Insufficient fixing could lead to the
motor deviating during operation. Failure to observe this could lead to
injuries.
3. When coupling to a servomotor shaft end, do not apply an impact by
hammering, etc. The detector could be damaged.
4. Never touch the rotary sections of the motor during operations. Install a
cover, etc., on the shaft.
5. Do not apply a load exceeding the tolerable load onto the servomotor shaft.
The shaft could break. Failure to observe this could lead to injuries.
6. Do not connect or disconnect any of the connectors while the power is ON.
0°C to +40°C
80%RH or less
–15°C to +70°C
90%RH or less
Indoors (Where unit is not subject to direct sunlight)
No corrosive gases, flammable gases, oil mist or dust
Operation/storage: 1000m or less above sea level
Transportation: 10000m or less above sea level
HC52 to 153, HC103R to 503R
HC202 to 353
HC452 to 703
HC902
HA053N to 33N
HA-LF11K2-S8, HA-LF15K2-S8
Conditions
(with no freezing)
(with no dew condensation)
(with no freezing)
(with no dew condensation)
X: 9.8m/s
Y: 24.5m/s
X: 19.6m/s
Y: 49.0m/s
X: 11.7m/s
Y: 24.5m/s
X: 9.8m/s
Y: 24.5m/s
X: 19.6m/s
Y: 19.6m/s
X: 11.7m/s
Y: 29.4m/s
1 - 2
(1G)
2
(2.5G)
2
(2G)
2
(5G)
2
(1.2G)
2
(2.5G)
2
(1G)
2
(2.5G)
2
(2G)
2
(2G)
2
(1.2G)
2
(3G)
2