(4) Spindle control output 4
Name
Spindle control output 4
bit0. Current detection (CD)
This signal turns ON when the start signal (forward run, reverse run, orientation) is ON, and the
current flowing to the motor is approx. 110% or more of the rating. (The motor output (current)
guarantee value is 120% of the rating.)
bit1. Speed detection 1 (SD1)
This signal turns ON when the motor speed drops below the value set with parameter SP020
(SDTS). The ON to OFF hysteresis width is set with parameter SP047 (SDTR). This signal turns
ON when the motor's speed is less than the set speed regardless of the input signal state.
Motor speed
Speed detection 1 (SD1)
5. Spindle Adjustment
F
E
D
C
B
A
TLUA
ATA
bit
0
CD
Current detection
1
Speed detection 1
SD1
2
Up-to-speed
US
3
Zero speed
ZS
4
Orientation complete
ORCF
5
Synchronous speed match
SYSA
6
Changing coil
MKC
7
WRCF
Index positioning completed
8
9
Speed detection 2
SD2
A
B
C
D
In automatic adjustment (only for MDS-C1-SPM)
ATA
E
TLUA
Spindle holding force increased
F
SP047
SP020
0
ON
OFF
Speed detection 1 (SD1) sequence
5 - 12
Details
9
8
7
6
5
4
SD2
MKC
SYSA
WRCF
ORCF
Details
3
2
1
0
ZS
US
SD1
CD