Mitsubishi MELDAS MDS-C1 Instruction Manual page 46

Ac servo/spindle
Table of Contents

Advertisement

(5) Connecting the HA053N/HA13N
Detector connector
Option cable : CNV12
MS3102A22-14P
(Refer to Appendix 1 for details
on the cable treatment.)
L
K
N
J
H
S
R
E
Pin
Name
A
B
C
D
E
BAT
F
G
H
SD
J
SD*
K
RQ
L
RQ*
M
N
FG
P
R
LG(GND)
S
P5(+5V)
T
U
V
2. Wiring and Connection
CN2
Max. 30m
2 - 13
MDS-C1-V1
Detector connector : CN2
Pin
1
2
3
4
5
6
7
8
9
10
Power wire and grounding wire
U V W
(Refer to Specification manual for details
on selecting the wire.)
Power connector
Pin
Name
MS3102A18-12
A
U
B
V
A
C
W
F
D
Grounding
B
E
E
F
C
D
Pin No.
No.1
No.11
No.10
No.20
Name
Pin
Name
LG
11
LG
12
13
14
15
SD
16
SD*
RQ
17
RQ*
18
BAT
19
P5(+5V)
P5(+5V)
20
P5(+5V)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents