Mitsubishi MELDAS MDS-C1 Instruction Manual page 146

Ac servo/spindle
Table of Contents

Advertisement

No.
Abbr.
Parameter name
SP039
ATYP* Drive unit type
SP040 MTYP* Motor type
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
Details
Set the spindle drive unit's capacity type.
Setting
Unit capacity
0000
---
0001
SP-075
0002
SP-15
0003
SP-22
0004
SP-37
0005
SP-55
0006
SP-75
0007
SP-110
0008
SP-150
0009
SP-185
000A
SP-220
000B
SP-260
000C
SP-300
000D
SP-370
000E
SP-450
000F
SP-04
This parameter is valid when SP034 (SFNC2) bit0 is set
to "0". (Old type of motor)
Set the appropriate motor number from the standard
motors listed below.
Maximum
Setting Motor name
0000
---
0001
SJ-2.2A
10000 r/min
0002
SJ-3.7A
10000 r/min
0003
SJ-5.5A
0004
SJ-7.5A
0005
SJ-11A
0006
SJ-15A
0007
SJ-18.5A
0008
SJ-22A
0009
SJ-26A
000A
SJ-30A
000B
---
000C
---
000D
---
000E
---
000F
---
0010
---
0011
SJ-N0.75A
10000 r/min
0012
SJ-N1.5A
10000 r/min
0013
SJ-N2.2A
10000 r/min
0014
SJ-N3.7A
10000 r/min
0015
SJ-N5.5A
0016
SJ-N7.5A
0017
---
0018
---
0019
---
001A
---
001B
---
001C
---
001D
---
001E
---
001F
---
3 - 67
HEX setting
Setting
Unit capacity
0010
SP-550
0011
---
0012
---
0013
---
0014
---
0015
---
0016
---
0017
---
0018
---
0019
---
001A
---
001B
---
001C
---
001D
---
001E
---
001F
---
HEX setting
Correspond-
ing drive
speed
unit
---
---
SP-22
SP-37
8000 r/min
SP-55
8000 r/min
SP-75
6000 r/min
SP-110
6000 r/min
SP-150
6000 r/min
SP-185
4500 r/min
SP-220
4500 r/min
SP-260
4500 r/min
SP-300
---
---
---
---
---
---
---
---
---
---
---
---
SP-075
SP-15
SP-22
SP-37
8000 r/min
SP-55
8000 r/min
SP-75
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Setting range
Standard
(Unit)
setting
0000 to FFFF
0000
0000 to FFFF
0000

Hide quick links: