Mitsubishi MELDAS MDS-C1 Instruction Manual page 97

Ac servo/spindle
Table of Contents

Advertisement

High-gain specifications
No.
Abbrev.
Parameter name
Position detector
SV019
RNG1*
resolution
Speed detector
SV020
RNG2*
resolution
Overload detection
SV021
OLT
time constant
Overload detection
SV022
OLL
level
Excessive error
SV023
OD1
detection width
during servo ON
In-position
SV024
INP
detection width
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.
3. Setup
In the case of the semi-closed loop control
Set the same value as SV020 (RNG2). (Refer to the explanation of
SV020.)
In the case of the full-closed loop control
Set the number of pulses per ball screw pitch.
Detector model name
OHE25K-ET, OHA25K-ET
OSE104-ET,OSA104-ET
OSE105-ET,OSA105-ET
RCN723 (Heidenhain)
Relative position
detection scale
AT41 (Mitsutoyo)
FME type, FLE type
(Futaba)
MP type (Mitsubishi
Heavy Industries)
AT342 (Mitsutoyo)
AT343 (Mitsutoyo)
LC191M (Heidenhain)
LC491M (Heidenhain)
Set the number of pulses per one revolution of the motor end detector.
Detector model name
OSE104, OSA104
OSE105, OSA105
Set the detection time constant of Overload 1 (Alarm 50).
Set to "60" as a standard. (For machine tool builder adjustment.)
Set the current detection level of Overload 1 (Alarm 50) in respect to the
stall (rated) current.
Set to "150" as a standard. (For machine tool builder adjustment.)
Set the excessive error detection width when servo ON.
<Standard
setting value>
OD1=OD2=
When "0" is set, the excessive error detection will not be performed.
Set the in-position detection width.
Set the accuracy required for the machine.
The lower the setting is, the higher the positioning accuracy gets, however,
the cycle time (setting time) becomes longer. The standard setting is "50".
3 - 18
Explanation
Resolution
SV019 setting
100,000 (p/rev)
100,000 (p/rev)
1,000,000 (p/rev)
8,000,000 (p/rev)
Refer to specification
PIT/Resolution
manual for each detector
The same as
µ
1 (
m/p)
SV018 (PIT)
Refer to specification
PIT/Resolution
manual for each detector
Refer to specification
PIT/Resolution
manual for each detector
Twice as big as
µ
0.5 (
m/p)
SV018 (PIT)
20 times as big
µ
0.05 (
m/p)
as SV018 (PIT)
Refer to specification
PIT/Resolution
manual for each detector.
Refer to specification
PIT/Resolution
manual for each detector.
SV020 setting
Rapid traverse rate
(mm/min)
×
60
PGN1
Setting range
(Unit)
1 to 9999
(kp/rev)
100
100
1000
8000
µ
(
m)
1 to 9999
(kp/pit)
µ
(
m)
µ
(
m)
µ
(
m)
µ
(
m)
1 to 9999
100
(kp/rev)
1000
1 to 999
(s)
110 to 500
(Stall [rated]
current %)
0 to 32767
÷
2 (mm)
(mm)
0 to 32767
(µm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents