High-gain specifications
No.
Abbrev.
Parameter name
SV025
MTYP* Motor/Detector type
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.
3. Setup
F
E
D
C
B
A
pen
ent
bit
0
Set the motor type. Set this along with SV017 (SPEC)/spm.
1
1) When SV017/spm=0 (Normal drive unit)
2
Setting
0x
3
x0
HA40N
mtyp
4
x1
HA80N
5
x2
HA100N
6
x3
HA200N
7
x4
HA300N
x5
HA700N
x6
HA900N
x7
x8
x9
xA
xB
xC
xD
xE
xF
Setting
8x
x0
HA43N
x1
HA83N
x2
HA103N
x3
HA203N
x4
HA303N
x5
HA703N
x6
x7
x8
x9
xA
HA93N
xB
xC
HA053N
xD
HA13N
xE
HA23N
xF
HA33N
2) When SV017/spm=1 (S type drive unit)
Setting
8x
x0
x1
x2
x3
x4
x5
x6
x7
x8
x9
xA
xB
xC
xD
xE
xF
3 - 19
Explanation
9
8
7
6
5
4
mtyp
Explanation
1x
2x
3x
HA50L
HA53L
HA100L
HA103L
HA200L
HA203L
HA300L
HA303L
HA500L
HA503L
HALH11K2
HALH15K2
HA150L
HA153L
HALF11K2
HA-LF15K2
9x
Ax
Bx
Cx
HC52
HC53
HC102
HC103
HC152
HC153
HC202
HC203
HC352
HC353
HC452
HC453
HC702
HC703
HC902
9x
Ax
Bx
HC353
HC452
HC453
HC702
HC703
HC902
3
2
1
0
4x
5x
6x
7x
Dx
Ex
Fx
HC103R
HC153R
HC203R
HC353R
HC503R
Cx Dx Ex Fx