Standard specifications
No.
Abbrev.
Parameter name
Dual feed back
SV051
DFBT
control time constant
Dual feedback
SV052
DFBN
control dead zone
Excessive error
SV053
OD3
detection width in
special control
Overrun detection
SV054
ORE
width in closed loop
control
Max. gate off delay
SV055
EMGx
time after
emergency stop
Deceleration time
SV056
EMGt
constant at
emergency stop
SV057
SHGC
SHG control gain
SHG control gain in
SV058 SHGCsp
spindle
synchronous control
Collision detection
SV059
TCNV
torque estimating
gain
Collision detection
SV060
TLMT
level
D/A output channel 1
SV061
DA1NO
data No.
D/A output channel 2
SV062
DA2NO
data No.
D/A output channel 1
SV063 DA1MPY
output scale
D/A output channel 2
SV064 DA2MPY
output scale
SV065
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.
3. Setup
Set the control time constant in dual feed back.
When "0" is set, the actual value that is set is 1msec.
The higher the time constant is, the closer it gets to the semi-closed control,
so the limit of the position loop gain is raised.
Set to "0" as a standard.
Set the dead zone in the dual feedback control.
Set the excessive error detection width when servo ON in a special control
(initial absolute position setting, stopper control, etc.).
If "0" is set, excessive error detection won't be performed.
Set the overrun detection width in the full-closed loop control.
If the gap between the motor end detector and the linear scale (tool end
detector) exceeds the value set by this parameter, it is judged to be overrun
and Alarm 43 will be detected.
When "-1" is set, the alarm detection won't be performed. When "0" is set,
overrun is detected with a 2mm width.
Set a length of time from the point when the emergency stop is input to the
point when READY OFF is compulsorily executed.
Normally, set the same value as the absolute value of SV056.
In preventing the vertical axis from dropping, the gate off is delayed for the
length of time set by SV048 if SV055's value is smaller than that of SV048.
Set the time constant used for the deceleration control at emergency stop.
Set a length of time that takes from rapid traverse rate (rapid) to stopping.
Normally, set the same value as the rapid traverse acceleration/deceleration
time constant.
When executing the synchronous operation, put the minus sign to the
settings of both of the master axis and slave axis.
When performing the SHG control, set this with S003 (PGN1) and SV004
(PGN2).
When not performing the SHG control, set to "0".
Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform
the SHG control in the synchronous tapping control.
When not performing the SHG control, set to "0".
Set the torque estimating gain when using the collision detection function.
After setting as SV035/bitF(clt)=1 and performing acceleration/deceleration,
set the value displayed in MPOS of the NC servo monitor screen.
Set to "0" when not using the collision detection function.
When using the collision detection function, set the collision detection level
during the G0 feeding.
If "0" is set, none of the collision detection function will work.
Input the data number you wish to output to D/A output channel.
In the case of MDS-C1-V2, set the axis on the side to which the data will not
be output to "-1".
Set the scale with a 1/256 unit.
When "0" is set, output is done with the standard output unit.
Not used. Set to "0".
3 - 50
Explanation
Setting range
(Unit)
0 to 9999
(ms)
0 to 9999
(µm)
0 to 32767
(mm)
-1 to 32767
(mm)
0 to 20000
(ms)
-20000 to
20000
(ms)
0 to 999
(rad/s)
0 to 999
(rad/s)
-32768 to
32767
0 to 999
(Stall [rated]
current %)
-1 to 127
-32768 to
32767
(Unit: 1/256)
0