Mitsubishi MELDAS MDS-C1 Instruction Manual page 148

Ac servo/spindle
Table of Contents

Advertisement

No.
Abbr.
Parameter name
SP045
CSNT Dual cushion timer
Speed command dual
SP046
CSN2*
cushion
Speed detection reset
SP047
SDTR*
value
SP048
SUT*
Speed reach range
SP049
TLM2
Torque limit 2
SP050
TLM3
Torque limit 3
SP051
TLM4
Torque limit 4
SP052
TLM5
Torque limit 5
SP053
TLM6
Torque limit 6
SP054
TLM7
Torque limit 7
Excessive speed
SP055 SETM*
deviation timer
Variable excitation
SP056
PYVR
(min value)
Constant → transition
SP057 STOD*
judgment value
Speed detection setting
SP058
SDT2*
value 2
Winding changeover
SP059
MKT*
base shut-off timer
Current limit timer after
SP060
MKT2*
coil changeover
Current limit value after
SP061
MKIL*
coil changeover
SP062
Overload alarm detection
SP063
OLT*
time
Overload alarm detection
SP064
OLL*
level
Target value of variable
SP065 VCGN1*
speed loop proportional
gain
Change starting speed of
SP066 VCSN1*
variable speed loop
proportional gain
Change starting speed of
SP067 VIGWA*
variable current loop gain
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
Details
Set the cycle to add the increment values in the dual
cushion process.
When this setting value is increased, the dual cushion will
increase, and the changes in the speed during
acceleration/deceleration will become gradual.
For an acceleration/deceleration time constant defined in
SP019 (CSN1) , this parameter is used to provide smooth
movement only at the start of acceleration/deceleration.
As the value of this parameter is smaller, it moves
smoother but the acceleration/deceleration time becomes
longer.
To make this parameter invalid, set "0".
Set the reset hysteresis width for a speed detection set
value defined in SP020 (SDTS).
Set the speed deviation rate with respect to the
commanded speed for output of the speed reach signal.
Set the torque limit rate for the torque limit signal 010.
Set the torque limit rate for the torque limit signal 011.
Set the torque limit rate for the torque limit signal 100.
Set the torque limit rate for the torque limit signal 101.
Set the torque limit rate for the torque limit signal 110.
Set the torque limit rate for the torque limit signal 111.
Set the timer value until the excessive speed deviation
alarm is output.
The value of this parameter should be longer than the
acceleration/deceleration time.
Set the minimum value of the variable excitation rate.
Select a smaller value when gear noise is too high.
Set the value for judging when changing the speed
command from a constant to acceleration/deceleration.
Set the motor speed for carry out speed detection 2
output.
Set the base shut-off time for contactor switching at coil
changeover.
Note that the contactor may be damaged with burning if
the value of this parameter is too small.
Set the current limit time to be taken after completion of
contactor switching at coil changeover.
Set the current limit value during a period defined in
SP060 (MKT2) after completion of contactor switching at
coil changeover.
Not used. Set to "0".
Set the time constant for detection of the motor overload
alarm.
Set the detection level of the motor overload alarm.
Set the magnification of speed loop proportional gain with
respect to SP022 (VGNP1) at the maximum motor speed
defined in SP017 (TSP).
Set the speed when the speed loop proportional gain
change starts.
Proportional gain
SP022
SP022×
(SP065/100)
SP066
Set the speed where the current loop gain change starts.
3 - 69
Setting range
0 to 1000 (ms)
0 to 1000
0 to 1000
0 to 100 (%)
0 to 120 (%)
0 to 120 (%)
0 to 120 (%)
0 to 120 (%)
0 to 120 (%)
0 to 120 (%)
0 to 160 (s)
0 to 100 (%)
0 to 50 (r/min)
0 to 32767
50 to 10000
0 to 10000
0 to 120 (%)
0 to 1000 (s)
0 to 120 (%)
0 to 100 (%)
0 to 32767
Speed
SP017
0 to 32767
Standard
(Unit)
setting
0
0
30
(r/min)
15
20
30
40
50
60
70
12
50
0
0
(r/min)
150
(ms)
500
(ms)
75
0
0
60
110
100
0
(r/min)
0
(r/min)