5-2-2
Spindle control output (SP to NC)

(1) Spindle control output 1

Name

Spindle control output 1

bit0. In READY ON (RON)
When the READY ON signal is input from the NC, if there is no abnormality, this signal turns on in
approx. one second. If the start signal (forward run, reverse run, orientation) is turned ON while this
signal is ON, the motor will start rotating. If an alarm occurs in the spindle drive unit, this signal will
turn OFF. If the READY ON signal from the NC turns OFF while the spindle motor is rotating, the
motor will decelerate to a stop, but this signal will remain ON until the motor stops.
bit1. In servo ON (SON)
bit4. In drive unit warning (WRN)
This signal turns ON when a warning is occurring in the spindle drive unit.
bit6. In parameter conversion (PRMA)
The parameters sent from the NC are converted into effective parameters for spindle control.
bit7. In drive unit alarm (ALM)
This signal turns ON when an alarm is occurring in the spindle drive unit.
bit8. In torque limit 1 signal input (TL1A)
bit9. In torque limit 2 signal input (TL2A)
bitA. In torque limit 3 signal input (TL3A)
The respective signal turns ON when the torque limit signal 1 to 3 is input.
bitD. Z-phase passed (ZFIN)
This signal turns ON when the Z-phase is passed for the first time after servo ON during position
control.
5. Spindle Adjustment
F
E
D
C
B
A
CL
INP ZFIN
TL3A TL2A TL1A
bit
0
In READY ON
RON
1
In servo ON
SON
2
3
4
In drive unit warning
WRN
5
6
PRMA
In parameter conversion
7
ALM
In drive unit alarm
8
In torque limit 1 signal input
TL1A
9
In torque limit 2 signal input
TL2A
A
TL3A
In torque limit 3 signal input
B
C
D
ZFIN
Z-phase passed
E
INP
In position loop in-position
F
CL
Limiting current
5 - 9
Details
9
8
7
6
5
4
ALM
PRMA
WRN
Details
3
2
1
0
SON RON