Gain Adjustment; Current Loop Gain; Speed Loop Gain - Mitsubishi MELDAS MDS-C1 Instruction Manual

Ac servo/spindle
Table of Contents

Advertisement

4-2

Gain adjustment

4-2-1

Current loop gain

No.
Abbrev.
Parameter name
SV009
IQA
Current loop q axis lead
compensation
SV010
IDA
Current loop d axis lead
compensation
SV011
IQG
Current loop q axis gain
SV012
IDG
Current loop d axis gain
4-2-2

Speed loop gain

(1) Setting the speed loop gain
The speed loop gain (SV005: VGN1) is an important parameter for determining the
responsiveness of the servo control. During servo adjustment, the highest extent that this value
can be set to becomes important. The setting value has a large influence on the machine cutting
precision and cycle time.
1) Refer to the following table and set the standard VGN1 according to the size of the entire load
inertia (motor and machine load inertia).
2) If the standard speed gain setting value is exceeded, the current command fluctuation will
increase even if the speed feedback fluctuates by one pulse. This can cause the machine to
vibrate easily, so set a lower value to increase the machine stability.
Isolated motor
500
<HC >
400
HC353~HC703
300
Standard
VGN1
200
100
0
100
200
<When machine resonance does not occur at the standard VGN1>
Set the standard VGN1. Use the standard value if no problem (such as machine resonance)
occurs. If sufficient cutting precision cannot be obtained at the standard VGN1, VGN1 can be
raised above the standard value as long as a 70 percent margin in respect to the machine
resonance occurrence limit is maintained. The cutting accuracy can also be improved by adjusting
with the disturbance observer.
<When machine resonance occurs at the standard VGN1>
Machine resonance is occurring if the shaft makes abnormal sounds when operating or stopping,
and a fine vibration can be felt when the machine is touched while stopped. Machine resonance
occurs because the servo control responsiveness includes the machine resonance points. (Speed
control resonance points occur, for example, at parts close to the motor such as ball screws.)
Machine resonance can be suppressed by lowering VGN1 and the servo control responsiveness,
but the cutting precision and cycle time are sacrificed. Thus, set a vibration suppression filter and
suppress the machine resonance (Refer to section "4-3-2 Vibration suppression measures"), and
set a value as close as possible to the standard VGN1. If the machine resonance cannot be
sufficiently eliminated even by using a vibration suppression filter, then lower the VGN1.
4. Servo Adjustment
Set the gain of current loop.
As this setting is determined by the motor's electrical
characteristics, the setting is fixed for each type of motor.
Set the standard values for all the parameters depending on
each motor type.
High-gain specifications
HC202~HC902
HC53~HC203
HC52~HC152
300
400
500
Load inertia scale (%)
Explanation
Isolated motor
500
<HA N>
400
HA80N/100N/900N
HA43N~HA103N
300
200
100
0
600
100
200
Load inertia scale (%)
4 - 4
Setting range
1 to 20480
1 to 4096
High-gain specifications
HA200N~HA700N
HA203N~HA703N
HA40N
HA053~HA33N
300
400
500
600

Hide quick links: