No.
Abbr.
Parameter name
SP035 SFNC3* Spindle function 3
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
<For MDS-C1-SP/SPH/SPX/SPHX>
F
E
D
C
B
bit
Meaning when set to 0
H-coil wide-range constant output
0
hwid
invalid
L-coil wide-range constant output
1
lwid
invalid
2 hbsd H-coil base slide invalid
3
lbsd L-coil base slide invalid
4
5
6
7
8
9
A
B
C
D
E
F
(Note) Set 0 if there is no particular explanation for the bit.
<For MDS-C1-SPM>
F
E
D
C
B
bit
Meaning when set to 0
H coil output characteristic
0
hwid
change invalid
L coil output characteristic
1
lwid
change invalid
M coil output characteristic
2 mwid
change invalid
3
4
5
6
7
8
9
A
B
C
D
E
F
(Note) Set 0 if there is no particular explanation for the bit.
3 - 61
Details
A
9
8
7
6
5
Meaning when set to 1
H-coil wide-range constant output
valid
L-coil wide-range constant output
valid
H-coil base slide valid
L-coil base slide valid
A
9
8
7
6
5
Meaning when set to 1
H coil output characteristic
change valid
L coil output characteristic
change valid
M coil output characteristic
change valid
4
3
2
1
0
lbsd hbsd lwid hwid
Standard
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
0
mwid
lwid hwid
Standard
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0