Host List Promotion; Disconnect Mode; To Configure Tunnel Disconnect Mode Settings; Table 10-7 Tunnel Disconnect Mode Settings - Lantronix PREMIERWAVE XC HSPA+ User Manual

Intelligent gateway
Hide thumbs Also See for PREMIERWAVE XC HSPA+:
Table of Contents

Advertisement

Simultaneous – A tunnel will connect to all hosts accepting a connection. Simultaneous
connections occur at the same time to all listed hosts. The device can support a maximum of
64 total aggregate connections.

Host List Promotion

This feature allows Host IP promotion of individual hosts in the overall sequence.
To promote a specific Host:
1. Click the
2. The selected Host(s) exchanges its place with the Host above it.
3. Click Submit. The hosts change sequence.

Disconnect Mode

Specifies the optional conditions for disconnecting any Accept Mode or Connect Mode connection
that may be established. If any of these conditions are selected but do not occur and the network
disconnects to the device, a Connect Mode connection will attempt to reconnect. However, if none
of these conditions are selected, a closure from the network is taken as a disconnect.
Tunnel Disconnect
Mode Settings
Stop Character
Modem Control
Timeout
Flush Serial Data

To Configure Tunnel Disconnect Mode Settings

Using Web Manager
To configure the Disconnect Mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Disconnect Mode.
Using the CLI
To enter the Tunnel 1 Disconnect command level: enable -> tunnel 1 -> disconnect
PremierWave® XC HSPA+ Intelligent Gateway User Guide
icon in the desired Host field, for example Host 2 and Host 3.

Table 10-7 Tunnel Disconnect Mode Settings

Description
Enter the Stop Character which, when received on the Serial Line, disconnects the
tunnel. The Stop Character may be designated as a single printable character or
as a control character. Control characters may be input in any of the following
forms: <control>J or 0xA(hexadercimal) or \10 (decimal). Disable the Stop
Character by blanking the field to set it to <None>.
Set whether Modem Control enables disconnect when the Modem Control pin is not
asserted on the Serial Line. Choices are:
Enabled
Disabled (default)
Enter the number of milliseconds a tunnel may be idle before disconnection. The
value of zero disables the idle timeout.
Set whether to flush the Serial Line when the Tunnel is disconnected. Choices are:
Enabled
Disabled (default)
10: Line and Tunnel Settings
78

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PREMIERWAVE XC HSPA+ and is the answer not in the manual?

Table of Contents