Air Flow Sensor - wsm L3301 Workshop Manual

Hide thumbs Also See for L3301:
Table of Contents

Advertisement

L3301, L3901, L4701, WSM

(8) Air Flow Sensor

NOTE
• Since it is not possible to do unit checking for this sensor, judge the sensor is damaged if the relating
electric circuit is normal.
Connector Voltage
1. Disconnect the connector, and turn the main key switch "ON"
position.
2. Measure the voltage with a voltmeter across the terminals
shown in the table below.
3. If the reference value is not indicated as shown in the table
below, check the relating electric circuit.
Main
Voltage
switch at
"ON"
(1) Air Flow Sensor
9-S48
ELECTRICAL SYSTEM
9Y1211012ELS0085US0
Terminal 1 –
Approx. battery voltage
Chassis
(2) Connector (Harness Side)
9Y1211012ELS0086US0
KiSC issued 09, 2016 A