wsm L3301 Workshop Manual page 71

Hide thumbs Also See for L3301:
Table of Contents

Advertisement

L3301, L3901, L4701, WSM
Replacing Fuse
1. The tractor electrical system is protected from potential damage
by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
2. If any of the fuses should blow, replace with a new one of the
same capacity.
IMPORTANT
• Before replacing a blown fuse, determine why the fuse blew
and make any necessary repairs. Failure to follow this
procedure may result in serious damage to the tractor
electrical system. Refer to "1. TROUBLESHOOTING" on
page 9-S1.
If any of them should blow, replace with a new one of the
same capacity.
Fuse No.
Capacity (A)
(1)
5
(2)
5
(3)
5
(4)
10
(5)
10
(6)
5
(7)
20
(8)
5
(9)
5
(10)
10
(11)
5
(12)
10
(13)
10
(14)
10
(15)
10
(16) Spare Fuse
(17) Fuse Puller
Replacing Slow-Blow Fuses
1. The slow-blow fuses are intended to protect the electrical
cabling. If any of them has blown out, be sure to pinpoint the
cause. Never use any substitute, use only a KUBOTA genuine
part.
No.
Capacity (A)
(1)
40
(2)
50
(3)
40
Replacing Light Bulb
Light
Head lights
Tail light
Turn signal / Hazard light (rear)
Turn signal / Hazard light (front)
G-47
Protected circuit
Engine ECU (Ignition key)
Main ECU (Ignition key)
Meter panel (Ignition key)
Combination switch
Work light
Starter relay
Engine ECU (Battery)
Main ECU (Battery)
Meter panel (Battery)
Hazard
Heater relay (if equipped)
Heater (Oil separator, IN 1) (if equipped)
Heater (Oil separator, IN 2) (if equipped)
Heater (Oil separator, OUT 1) (if equipped)
Heater (Oil separator, OUT 2) (if equipped)
(18) Spare fuse
9Y1211012GEG0123US0
Protected circuit
Load
Battery
Heater (Oil separator) (if equipped)
9Y1211012GEG0124US0
Capacity
25 W / 25 W
5 W
21 W
23 W
9Y1211012GEG0125US0
KiSC issued 09, 2016 A
GENERAL

Advertisement

Table of Contents
loading

This manual is also suitable for:

L3901L4701

Table of Contents