Antenna Alignment; Antenna Alignment Procedure; Figure 4-56 Waterproofing - Radwin 2000+ SERIES User Manual

Point to point broadband wireless
Table of Contents

Advertisement

Antenna Alignment
 
Figure 4‐56: Waterproofing an external connection
4.11 Antenna Alignment
An audible buzzer is used on both the Master ODU and the Slave ODU. If the external 
antenna is positioned so far away from the unit so as to make the buzzer inaudible, you 
may need to use two people to perform antenna alignment.
Antenna alignment is carried out in three stages: 
• Master ODU gross alignment
• Slave ODU fine alignment
• Master ODU fine alignment 
4.11.1 Antenna Alignment Procedure 
1.  Ensure that power is connected to all radio units. 
2. If you are working with an external antenna, connect the vertical polarization 
connector of the antenna to the ANT 1 connector of the radio unit, and the 
horizontal polarization connector of the antenna to the ANT 2 connector of the 
radio unit.
There is no particular reason to use ANT 1 and ANT 2 in that order: They 
just have to be the same for each ODU in the sector. Further, adopting a 
convention like "ANT 1 is always vertical" avoids mistakes across a large 
sector.
3.
Ensure that the buzzer on both radio units is configured to Auto (see Link 
Configuration Tool Bar on page 7‐27). An unaligned ODU starts beeping 20 seconds 
after power up, and continues beeping until it is aligned.
RADWIN 2000+ Series User Manual
Release  4.2.40
4‐39

Advertisement

Table of Contents
loading