Lightning Protection Unit (LPU) for CAT‐5e Cables
Figure 4‐54: Installing an LPU on a wall
Additional Considerations for Waterproofing
Protect all connections between any outdoor devices (ODUs, LPUs, Ethernet Repeaters, etc) 
and cables from rain, dust, moisture and salt according to the procedure below:  
1.  Use a high quality sealing material such as Scotch 23 Tape ¾" wide, to ensure IP‐67 
compliant protection against water and dust.
2. Cut two pieces each 25 cm long, of Scotch 23 splicing tape. Remove the plastic 
cover to expose the tacky side of the sealing tape as shown in Figure
Figure 4‐55: Exposing the tacky side of the sealing tape
3. After connecting a cable to a unit, tighten the cable gland cap firmly and use the 
insulation tape to fully cover the cable gland.