Using a Single HSS Unit
10.2.2 Using a Single HSS Unit
Figure 10‐2: HSS Wiring schematic
The wiring for a single HSS is shown in Figure
10‐2. 
The Sync signal path is as follows: If we set ODU 1 (on SYNC 1) to HSS Master, the Sync signal 
path is as shown in Figure
10‐3. The signal travels from ODU 1 to SYNC 1, from SYNC 1 to SYNC 
2, from SYNC 2 to ODU 2 and back again. The back and forth paths repeat for the second to 
fourth ODU, from left to right. The signal exits the HSS unit at SYNC 5 and terminates in ODU 
5.
The choice of the ODU on SYNC 1 as HSS master is not mandatory, but is good practice.  If for 
example we were to use ODU 3 as HSS master, the Sync signal path would be ODU 3 to SYNC 
3, then left and right to SYNC 2 and SYNC 4. It would then propagate to ODUs 2 and 4, 
terminating at both ODUs 1 and 5.   
Figure 10‐3: HSS sync signal path with ODU 1 as HSS Master
RADWIN 2000+ Series User Manual
Release  4.2.40