Lightning Protection Unit (LPU) for CAT‐5e Cables
Figure 4‐50: LPU attached to pole with metal tie
3. Tighten the metal tie.
4. Connect the grounding lug to a grounding source.
5. Remove the cable glands.
6. Thread the CAT‐5e cables through the cable glands, and connect the cables to the
LPU as shown in Figure
7.
Tighten the cable glands around the CAT‐5e cables as shown in Figure
Figure 4‐51: Connecting cables to the LPU (1) Figure 4‐52: Connecting cables to the LPU (2)
8. Route one CAT‐5e up to the ODU, and the other down to the IDU or PoE (via the
lower LPU). An LPU installed on a pole is shown in Figure
9. RADWIN recommends that you add extra waterproofing to the connections
(see Additional Considerations for Waterproofing on page 4‐38).