Ethernet Hub Site Synchronization
complete description of the HSS serial connections are more complex ‐ see SHSS Hardware
Installation on page 10‐1. for complete directions.
RADWIN recommends that you seal each connection against water leakage. See Additional
Considerations for Waterproofing for instructions on doing so.
Figure 4‐42: Connections: Serial HSS using the HSS unit
4.9.2 Ethernet Hub Site Synchronization
In this case, the relevant units are connected via a the IDU‐H/HP.
The units are connected to the PoE port on the IDU‐H/HP. The port the radio unit uses for this
connection depends on the specific model you are working with, as follows:
•
RADWIN 2000 C+: Connect to IDU port
•
RADWIN 2000 D+: Connect to IDU port
•
RADWIN 2000 A+: Connect to PoE port
•
RADWIN 2000i: Connect to either the LAN1 or LAN2 port
The Ethernet HSS (HSSoE) method requires Layer 2 Ethernet connectivity
between collocated ODUs. For more details, see HSSoE Concepts.