NOTES:
1. A Primary Protector is not required to protect the exposed wiring as long as the exposed 
wiring length is limited to less than or equal to 140 feet, and instructions are provided to 
avoid exposure of wiring to accidental contact with lightning and power conductors in 
accordance with NEC Sections 725‐54 (c) and 800‐30.
In all other cases, an appropriate Listed Primary Protector must be provided. Refer to Articles 
800 and 810 of the NEC for details.
2. For protection of ODU against direct lightning strikes, appropriate requirements of NFPA 
780 should be considered in addition to NEC.
3. For Canada, appropriate requirements of the CEC 22.1 including Section 60 and additional 
requirements of CAN/CSA‐B72 must be considered as applicable.