Displaying Show Sflow On An Interface; Displaying Show Sflow On A Line Card - Dell C9000 Series Networking Configuration Manual

Hide thumbs Also See for C9000 Series:
Table of Contents

Advertisement

77 UDP packets exported
0 UDP packets dropped
165 sFlow samples collected
69 sFlow samples dropped due to sub-sampling
Linecard 1 Port set 0 H/W sampling rate 8192
Te 1/16: configured rate 8192, actual rate 8192, sub-sampling rate 1
Te 1/17: configured rate 16384, actual rate 16384, sub-sampling rate 2

Displaying Show sFlow on an Interface

To view sFlow information on a specific interface, use the following command.
Display sFlow configuration information and statistics on a specific interface.
EXEC mode
show sflow interface interface-name
Examples of Viewing a sFlow Configuration
The following example shows the show sflow interface command.
Dell#show sflow interface tengigabitethernet 1/16
Te 1/16
Configured sampling rate
Actual sampling rate
Sub-sampling rate
Counter polling interval
Samples rcvd from h/w
Samples dropped for sub-sampling :6
The following example shows the show running-config interface command.
Dell#show running-config interface tengigabitethernet 1/16
!
interface TenGigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow enable
sflow sample-rate 8192
no shutdown

Displaying Show sFlow on a Line Card

To view sFlow statistics on a specified line card, use the following command.
Display sFlow configuration information and statistics on the specified interface.
EXEC mode
show sflow linecard slot-number
Example of Viewing sFlow Configuration (Line Card)
Dell#show sflow linecard 1
Linecard 1
:8192
:8192
:2
:15
:33
sFlow
1036