Control Gain Switching Function - Omron 3G3RX User Manual

Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

4-2 Function Mode
•The following operations become possible when 20 (STA), 21 (STP), and 22 (F/R) are allocated to
any of multi-function inputs 1 to 8 (C001 to C008). Allocating the STP terminal disables the FW and
RV terminals.
•Below are the outputs via terminal operation.
4

Control Gain Switching Function

•This function provides two types of gain and time constant settings for the speed control system
(proportional/integral compensation). You can switch over these settings when "sensorless vector
control", "0-Hz sensorless vector control", or "sensor vector control" is selected as the control
method.
Parameter No.
A044/A244
C001 to C008
H005/H205
H050/H250
H051/H251
H052/H252
H070
H071
H072
H073
•If control gain switching is selected in the multi-function input selection, turning off the signal
selects the gain setting of H050, H250, H051, H251, H052, or H252. Turning on the signal selects
the gain setting of H070, H071, or H072.
•If control gain switching is not selected in multi-function inputs 1 to 8 (C001 to C008), the gain
setting conforms to the status in which the signal is turned off.
4-89
STA
STP
F/R
Output frequency
Function name
V/f characteristics selection
Multi-function inputs
1 to 8 selection
Speed response
PI proportional gain
PI integral gain
P proportional gain
For PI proportional gain
switching
For PI integral gain switching 0.0 to 1000.0
For P proportional gain
switching
Gain switching time
ON
OFF
ON
OFF
Forward
Reverse
Data
03: SLV (Sensorless vector control)
04: 0SLV (0-Hz sensorless vector
control)
05: V2 (Sensor vector control)
26: CAS (control gain switching)
0.001 to 80.000
0.0 to 1000.0
0.0 to 1000.0
0.01 to 10.00
0.0 to 1000.0
0.00 to 10.00
0 to 9999 (ms):
Taper time during gain switching
Default setting
Unit
00
1.590
100.0
%
100.0
%
1.00
100.0
%
100.0
%
1.00
100
ms