Torque Bias Function

This function applies bias to the torque reference generated by speed control, and is useful for ele-
vating applications (e.g. elevator).
Parameter No.
Function name
P036
Torque bias mode
P037
Torque bias value
Torque bias polarity
P038
selection *
Related functions
*1. When torque bias is set to the O2 terminal, -10 to +10 (V) is recognized as -200 to +200 (%).
*2. • When "00" (As per sign) is selected:
When the polarity of a torque bias signal is (+), the torque increases for forward rotation, and when it is (-),
the torque increases for reverse rotation, regardless of the RUN direction.
• When "01" (Depends on the RUN direction) is selected:
The torque bias signal polarity and torque bias direction vary depending on the RUN command direction.
Forward command: Applies torque in the same direction as the torque bias.
Reverse command: Applies torque in the opposite direction of the torque bias.

Torque Control

Under this function, the Inverter can be used in torque control, as well as in the speed and pulse
train position controls.
Torque control can be applied to winders, and more.
To run the Inverter in torque control mode, allocate "52" (ATR) to any of the multi-function inputs.
While the ATR terminal is turned on, the torque reference input is enabled.
In torque reference input selection P033, you can select one of the three analog inputs or the input
via the Digital Operator.
The torque control speed depends on the balance between torque and load. To prevent the Inverter
from running out of control, set a speed limit value in P039 (forward) or P040 (reverse).
Parameter No.
Function name
Torque reference input
P033
P034
Torque reference setting
Polarity selection at
P035
torque reference via O2
4-3 Functions When PG Option Board (3G3AX-PG01) Is Used
00: OFF (Disabled)
01: OPE (Digital Operator)
02: O2 (Terminal O2) *
05: Option 1
06: Option 2
-200 to 200 (0.4 to 55 kW)
-180 to 180 (75 to 132 kW)
Enabled when P036 = 01
00: Sign (Signed)
01: Direction (Depends on the RUN
2
direction)
00: O (Terminal O)
01: OI (Terminal OI)
02: O2 (Terminal O2)
selection
03: OPE (Digital Operator)
06: Option 1
07: Option 2
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
Torque reference when P033 = 03
00: Sign (Signed)
01: Direction (Depends on the RUN
direction)
Data
Default setting
1
d010
Data
Unit
00
0
%
00
Default setting
Unit
00
0
%
00
-
4-126