Omron 3G3RX User Manual page 181

Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

•Intelligent output terminal that cannot set Normal Duty.
Code
19: BRK
20: BER
22: DSE
23: POK
•When the parameter becomes outside a set range when changing to Heavy Duty -> Normal Duty,
it changes to an initial value.
•An initial value of the following parameters is different in Heavy Duty ratings and Normal Duty
ratings. When Heavy Duty/Normal Duty is changed with b049, items other than H003/H203 are
changed to an initial value.
Func.
Name
code
00: VC (Const. torque)
01: VP (Reduced torque)
V/f
A044
02: Free V/F
characteristi
A244
03: SLV (sensorless vector)
cs selection
A344*
04: 0SLV (0-Hz sensorless)
05: V2 (Sensor vector)
DC injection
0 to 100 (%) 0.4 to 55kW
braking
A054
0 to 80 (%) 75 to 132kW
power
Startup DC
injection
0 to 100 (%) 0.4 to 55kW
A057
braking
0 to 80 (%) 75 to 132kW
power
DC injection
braking
0.5 to 15.0 (kHz) 0.4-55kW
A059
carrier
0.5 to 10.0 (kHz) 75-132kW
frequency
Electronic
(0.20 to 1.00) x Rated
b012
thermal level
current
Overload
b022/
(0.20 to 2.00) x Rated
limit level
b222
current (A) 0.4-55kW
(0.20 to 1.80) x Rated
Overload
b025
current (A) 75-132kW
limit level 2
Carrier
0.5 to 15.0 (kHz) 0.4-55kW
b083
frequency
0.5 to 10.0 (kHz) 75-132kW
Motor
H003/
capacity
0.2 to 160 (kW)
H203
selection
* For the A344 parameter there are only two options available: 00 (VC) and 01 (VP).
Intelligent output terminal name
Brake release
Brake error
Excessive speed deviation
Position ready
HD
Range
Initial data
00: Const.
torque
50% 0.4-55kW
40% 75-132kW
0 (%)
5.0 (kHz)
0.4-55kW
Rated current
(A)
1.50 x Rated
current (A)
5.0 (kHz)
0.4-55 kW
Depends on
type
4-2 Function Mode
ND
Range
00: VC (Const. torque)
01: VP (Reduced torque)
02: Free V/F
0 to 70 (%) 0.4 to 55kW
0 to 50 (%) 75 to 132kW
0 to 70 (%) 0.4 to 55kW
0 to 50 (%) 75 to 132kW
0.5 to 12.0 (kHz) 0.4-55kW
0.5 to 8.0 (kHz) 75-132kW
(0.20 to 1.00) x Rated
current
(0.20 to 1.50) x Rated
current (A)
0.5 to 10.0 (kHz) 0.4-55kW
0.5 to 8.0 (kHz) 75-132kW
0.4 to 160 (kW)
4
Initial data
00: Const.
torque
50% 0.4-55kW
40% 75-132kW
0 (%)
3.0 (kHz)
Rated current
(A)
1.20 x Rated
current (A)
3.0 (kHz)
One size up
than HD
4-62