Parameter
Function name
No.
Multi-function output
C021
terminal 11 selection
[Output [11] function]
Multi-function output
C022
terminal 12 selection
[Output [12] function]
Multi-function output
C023
terminal 13 selection
[Output [13] function]
Multi-function output
C024
terminal 14 selection
[Output [14] function]
Multi-function output
C025
terminal 15 selection
[Output [15] function]
Relay output (AL2,
AL1) function
C026
selection
[Alarm relay function]
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Monitor or data range
00: RUN (signal during RUN)
01: FA1 (constant speed arrival signal)
02: FA2 (over set frequency arrival signal)
03: OL (overload warning)
04: OD (excessive PID deviation)
05: AL (alarm output)
06: FA3 (set-frequency-only arrival signal)
07: OTQ (overtorque)
08: IP (signal during momentary power interruption)
09: UV (signal during undervoltage)
10: TRQ (torque limit)
11: RNT (RUN time over)
12: ONT (Power ON time over)
13: THM (thermal warning)
19: BRK (brake release)
20: BER (brake error)
21: ZS (0 Hz signal)
22: DSE (excessive speed deviation)
23: POK (position ready)
24: FA4 (set frequency exceeded 2)
25: FA5 (set frequency only 2)
26: OL2 (overload warning 2)
27: ODc (analog O disconnection detection)
28: OIDc (analog OI disconnection detection)
29: O2Dc (analog O2 disconnection detection)
31: FBV (PID FB status output)
32: NDc (network error)
33: LOG1 (logic operation output 1)
34: LOG2 (logic operation output 2)
35: LOG3 (logic operation output 3)
36: LOG4 (logic operation output 4)
37: LOG5 (logic operation output 5)
38: LOG6 (logic operation output 6)
39: WAC (capacitor life warning signal)
40: WAF (cooling fan life warning signal)
41: FR (starting contact signal)
42: OHF (fin overheat warning)
43: LOC (light load detection signal)
44: MO1 (Drive programming output 1)
45: MO2 (Drive programming output 2)
46: MO3 (Drive programming output 3)
47: MO4 (Drive programming output 4)
48: MO5 (Drive programming output 5)
49: MO6 (Drive programming output 6)
50: IRDY (operation ready signal)
51: FWR (forward run signal)
52: RVR (reverse run signal)
53: MJA (fatal fault signal)
54: WCO (window comparator O)
55: WCOI (window comparator OI)
56: WCO2 (window comparator O2)
63: OPO (Option board output)
no: Not used
(When C062 is used to select the alarm code
output, the multi-function output terminals 11 to
13, or 11 to 14 are forcibly changed to AC0 to
AC2 or AC0 to AC3 [Acn 'Alarm code output'],
respectively.)
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
00
21
03
No
07
01
05
App-28