Parameter
Function name
No.
O2 selection
A006
[O2 Select]
O start frequency
A011
[[O] start FQ]
O end frequency
A012
[[O] end FQ]
O start ratio
A013
[[O] start %]
O end ratio
A014
[[O] end %]
O start selection
A015
[[O] start FQ select]
O, O2, OI sampling
A016
[Analog-in filter]
Drive Programming
A017
(EzSQ) Selection
[EzSQ select]
Multi-step speed
A019
selection
[Multispeed select]
Multi-step speed
A020
reference 0
[Multispeed 0]
* 2nd multi-step
A220
speed reference 0
[Multispeed 0-M2]
* 3rd multi-step speed
A320
reference 0
[Multispeed 0-M3]
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Monitor or data range
00: [O2] only
01: [O/OI-P] auxiliary frequency reference
(not reversible)
02: [O/OI-PM] auxiliary frequency reference
(reversible)
03: [OFF] O2 disabled
0.00 to 400.00
0.00 to 400.00
0 to 100
0 to 100
00: External start frequency
(A011 set value)
01: 0 Hz
1 to 30
31 (with 500 ms filter ± 0.1 Hz hysteresis)
0: Disable
1: [PRG] start
2: Always ON
00: Binary: 16-step selection with 4 terminals
01: Bit: 8-step selection with 7 terminals
0.00 to Max. Frequency [A004]
0.00 to Max. Frequency [A204]
0.00 to Max. Frequency [A304]
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
03
No
0.00
No
Hz
0.00
No
Hz
0
No
%
100
No
%
01
No
31
No
00
No
00
No
6.00
Yes
Hz
6.00
Yes
Hz
6.00
Yes
Hz
App-6
Page
4-12
4-14
4-15
4-16
4-8
4-16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents