Parameter
Function name
No.
Overvoltage
protection function
b130
selection during
deceleration
Overvoltage
b131
protection level
during deceleration
Overvoltage
b132
protection parameter
Overvoltage
protection
b133
proportional gain
setting
Overvoltage
b134
protection integral
time setting
Auto return initial
b164
display
Data Read/Write
b166
selection
b180
Initialize trigger
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Monitor or data range
00: OFF (Disabled)
01: V-const (DC voltage kept constant)
02: Accel (Acceleration enabled)
200-V class: 330 to 390
400-V class: 660 to 780
0.10 to 30.00
0.00 to 2.55
0.000 to 65.535
00: OFF
01: ON
00: R/W OK (Read/Write OK)
01: R/W Protected (Read/Write Protected)
00: No action
01: Initialize
3-9 Parameter List
Changes
Default
during
Unit
Page
setting
operation
01
No
380/
No
V
760
1.00
No
s
4-78
0.50
Yes
0.060
Yes
s
00
No
00
No
00
No
3-40
3