<Command 09>
Checks if a set value can be stored in EEPROM.
•Transmission frame
Frame format
STX
Station No.
Description
STX
Control code (Start of TeXt)
Station No.
Station No. of the target Inverter
Command
Transmission command
BCC
Block check code
CR
Control code (Carriage Return)
•Response frame
Frame format
STX
Station No.
Description
STX
Control code (Start of TeXt)
Station No.
Station No. of the target Inverter
ACK
Control code (ACKnowledge)
Data
Data
BCC
Block check code
CR
Control code (Carriage Return)
Negative response: Refer to page 4-161.
<Command 0A>
Stores a set value in EEPROM.
•Transmission frame
Frame format
STX
Station No.
Description
STX
Control code (Start of TeXt)
Station No.
Station No. of the target Inverter
Command
Transmission command
BCC
Block check code
CR
Control code (Carriage Return)
•Response frame
Positive response: Refer to page 4-161.
Negative response: Refer to page 4-161.
Command
BCC
Data size
1 byte
2 bytes
2 bytes
2 bytes
1 byte
ACK
Data
Data size
1 byte
2 bytes
1 byte
2 bytes
2 bytes
1 byte
Command
BCC
Data size
1 byte
2 bytes
2 bytes
2 bytes
1 byte
4-4 Communication Function
CR
Setting
STX (0x02)
01 to 32
09
Exclusive OR from station No. to
data. (Refer to page 4-163.)
CR (0x0D)
BCC
CR
Setting
STX (0x02)
01 to 32
ACK (0x06)
01: Enabled
Exclusive OR from station No. to
data. (Refer to page 4-163.)
CR (0x0D)
CR
Setting
STX (0x02)
01 to 32
0A
Exclusive OR from station No. to
data. (Refer to page 4-163.)
CR (0x0D)
4
4-160