4-4 Communication Function
Register
No.
Multi-function output
141Fh
terminal 11 contact
selection
Multi-function output
1420h
terminal 12 contact
selection
Multi-function output
1421h
terminal 13 contact
selection
Multi-function output
4
1422h
terminal 14 contact
selection
Multi-function output
1423h
terminal 15 contact
selection
Relay output (AL2, AL1)
1424h
contact selection
1425h
Not used
Light load signal output
1426h
mode
1427h
Light load detection level
Overload warning signal
1428h
output mode
1429h
Overload warning level
142Ah
Arrival frequency during
acceleration
142Bh
142Ch
Arrival frequency during
deceleration
142Dh
PID deviation excessive
142Eh
level
142Fh
Arrival frequency during
acceleration 2
1430h
4-205
Function
Function name
code
C031
C032
C033
C034
C035
C036
C038
C039
C040
C041
C042
(HIGH)
C042
(LOW)
C043
(HIGH)
C043
(LOW)
C044
C045
(HIGH)
C045
(LOW)
R/W
Monitor and setting parameters
R/W
R/W
00: NO
R/W
01: NC
R/W
R/W
00: NO contact at AL2, NC contact at AL1
R/W
01: NC contact at AL2, NO contact at AL1
00: ACC/DEC/CST (Enabled during
acceleration/deceleration/constant
R/W
speed)
01: Const (Enabled only during constant
speed)
0.0 to 2.00 x Rated current (0.4 to 55 kW)
R/W
0.0 to 1.80 x Rated current (75 to 132 kW)
00: ACC/DEC/CST (Enabled during
acceleration/deceleration/constant
R/W
speed)
01: Const (Enabled only during constant
speed)
0.0: Does not operate.
0.1 x Rated current to 2.00 x Rated
R/W
current (0.4 to 55 kW)
0.1 x Rated current to 1.80 x Rated
current (75 to 132 kW)
R/W
0.00 to 400.00
R/W
R/W
0.00 to 400.00
R/W
R/W
0.0 to 100.0
R/W
0.00 to 400.00
R/W
Resolu-
tion
0.1 [A]
0.1 [A]
0.01
[Hz]
0.01
[Hz]
0.1 [%]
0.01
[Hz]