Appendix-1 Parameter List
Parameter
Function name
No.
Selection of non-stop
function at
b050
momentary power
interruption
[Ctrld decel. select]
Starting voltage of
non-stop function at
b051
momentary power
interruption
[DC Volt ctrld. decel]
Stop deceleration
level of non-stop
function at
b052
momentary power
interruption
[OV lvl ctrld. decel]
Deceleration time of
non-stop function at
b053
momentary power
interruption
[Decel time ctrld. dec]
Deceleration starting
width of non-stop
function at
b054
momentary power
interruption
[FQ drop ctrld. decel]
Proportional gain
setting of non-stop
function at
b055
momentary power
interruption
[P gain ctrld. decel]
Integral time setting
of non-stop function
b056
at momentary power
interruption
[I gain ctrld. decel]
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
App-21
Monitor or data range
00: OFF (Disabled)
01: V-Cnst (STOP) (Enabled (deceleration
stop))
02: NS1 (Enabled (without recovery))
03: NS2 (Enabled (with recovery))
0.0 to 1000.0
0.0 to 1000.0
0.01 to 3600.00
0.00 to 10.00
0.00 to 2.55
0.000 to 65.535
Changes
Default
during
Unit
Page
setting
operation
00
No
220/
No
V
440
360/
No
V
720
4-60
1.00
No
s
0.00
No
Hz
0.20
Yes
0.100
Yes
s
4-63