Advertisement

4-4 Communication Function
<Command 04>
Reads the Inverter status.
•Transmission frame
Frame format
Station No.
Command
4
•Response frame
Frame format
Station No.
*
Inverter status data includes the following three elements (A, B, and C).
Data
Inverter status A
Code
Status
00
Initial status
01
02
During stop
03
During RUN
04
During FRS
05
During JG
06
During DB
07
During retry
08
During trip
09
During UV
4-155
STX
Station No.
Command
Description
STX
Control code (Start of TeXt)
Station No. of the target Inverter
Transmission command
BCC
Block check code
CR
Control code (Carriage Return)
STX
Station No.
Description
STX
Control code (Start of TeXt)
Station No. of the target Inverter
Data
Data
BCC
Block check code
CR
Control code (Carriage Return)
Status A
Status B
Code
00
-
01
02
BCC
Data size
1 byte
2 bytes
2 bytes
2 bytes
1 byte
Data
BCC
Data size
1 byte
2 bytes
8 bytes
2 bytes
1 byte
Status C
00 (Reserved)
Inverter status B
Status
During stop
During RUN
During trip
CR
Setting
STX (0x02)
01 to 32
04
Exclusive OR from station No. to
data. (Refer to page 4-163.)
CR (0x0D)
CR
Setting
STX (0x02)
01 to 32
*
Exclusive OR from station No. to
data. (Refer to page 4-163.)
CR (0x0D)
Inverter status C
Code
Status
00
01
Stop
02
Deceleration
03
Constant speed
04
Acceleration
05
Forward
06
Reverse
07
Forward to reverse
08
Reverse to forward
09
Forward run start
10
Reverse run start
-