3-9 Parameter List

3-9 Parameter List
Monitor Mode (d)
•The default setting displays "d001" at power-on. To select the optional display, change the setting
in "b038".
3
Parameter
Function name
No.
Output frequency
d001
monitor
Output current
d002
monitor
Rotation direction
d003
monitor
PID feedback value
d004
monitor
Multi-function input
d005
monitor
Multi-function
d006
output monitor
Output frequency
d007
monitor
(after conversion)
Real frequency
d008
monitor
Torque reference
d009
monitor
Torque bias
d010
monitor
Output torque
d012
monitor
Output voltage
d013
monitor
d014
Input power monitor 0.0 to 999.9
Power ON time
d015
monitor
d016
Total RUN time
Power ON time
d017
monitor
Fin temperature
d018
monitor
3-21
Monitor or data range
0.00 to 400.00
0.0 to 9999.0
FWD: Forward
STOP: Stop
REV: Reverse
0.00 to 999000.00
(Enabled when the PID function is selected)
Example
MONITOR-A
M1-STOP ALL
FW, Multi-function input terminals 7, 2, 1: ON
d005 Input
Multi-function input terminals 8, 6, 5, 4, 3: OFF
HLHLLLLHH
FW
8
7
6
5
4
3
2
1
H001
00:OFF
Example
MONITOR-A
M1-STOP ALL
Multi-function output terminals 12, 11: ON
d006 Output
Relay output terminal AL2, Multi-function
LLLLH H
output terminals 15, 14, 13: OFF
15
12
11
AL2
14
13
H001
00:OFF
0.00 to 39960.00
(Output frequency × Conversion factor of b086)
-400.00 to 400.00
-200 to 200
-200 to 200
-200 to 200
0.0 to 600.0
0.0 to 999999.9
0 to 999999
0 to 999999
-020. to 200.0
Changes
Default
during
Unit
Page
setting
operation
Yes
Hz
A
Yes
Hz
%
%
%
V
W
h
h
C
4-1
4-1
4-1
4-1
4-2
4-2
4-2
4-3
4-3
4-3
4-3
4-3
4-4
4-4
4-4
4-4
4-4