Parameter
Function name
No.
Overtorque level
C055
(Forward power
running)
Overtorque level
C056
(Reverse
regeneration)
Overtorque level
C057
(Reverse power
running)
Overtorque level
C058
(Forward
regeneration)
Thermal warning
C061
level
C062
Alarm code selection
C063
0 Hz detection level
Fin overheat warning
C064
level
Communication
C071
speed selection
(Baud rate selection)
Communication
C072
station No. selection
Communication bit
C073
length selection
Communication
C074
parity selection
Communication stop
C075
bit selection
Communication error
C076
selection
Communication error
C077
timeout
Communication wait
C078
time
Communication
C079
method selection
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Monitor or data range
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
0 to 100
00: OFF (Disabled)
01: 3-bit
02: 4-bit
0.00 to 100.00
0 to 200
02: Loop-back test
03: 2400 bps
04: 4800 bps
05: 9600 bps
06: 19200 bps
1 to 247
7: 7-bit
8: 8-bit
00: No parity
01: Even
02: Odd
1: 1-bit
2: 2-bit
00: Trip
01: Decel-Trip (Trip after deceleration stop)
02: Ignore
03: Free-RUN (Free-run stop)
04: Decel-Stop (Deceleration stop)
0.00 to 99.99
0 to 1000
00: ASCII
01: ModBus-RTU
3-9 Parameter List
Changes
Default
during
Unit
Page
setting
operation
200
No
%
180
200
No
%
180
4-100
200
No
%
180
200
No
%
180
80
No
%
4-46
00
No
4-101
0.00
No
Hz
4-101
C
120
No
4-105
05
No
1
No
8
No
4-146
00
No
1
No
02
No
4-104
0.00
No
s
4-146
0
No
ms
4-146
01
No
3-46