Figure 151: Show Fanmodule Command; Figure 152: Show Card Command - Allied Telesis SwitchBlade x3106 Installation Manual

Table of Contents

Advertisement

Chapter 10: Verifying the Hardware Operations of the Chassis
214
The module is operating normally when its state is UP-UP-ONLINE, as
shown in Figure 151. If the state of the fan module is something other
than UP-UP-ONLINE, power off the chassis and contact your Allied
Telesis representative for assistance. Do not operate the chassis
without a fully operational fan unit.
SHOW FANMODULE
--- Fan Module ---
Fan Module..................... FM2
Module Number.................. AT-SBxFAN06
Serial Number.................. A0428400008
State.......................... UP-UP-Online
Actual
Fan Speed
Fan 1.................. 3897 rpm
Fan 2.................. 3903 rpm
Cold Temperature Shutdown... Off
Figure 151. SHOW FANMODULE Command
3. To view the states of the controller and line cards in the chassis, use
the SHOW CARD command.
An example of the status information is shown in Figure 152. A card is
operating normally when its state is UP-UP-ONLINE. If there is a
problem with a card, refer to "Ethernet Line Cards" on page 232 or "AT-
SBx31CFC960 Controller Fabric Card" on page 240 for
troubleshooting suggestions.
SHOW CARD
--- Card Information ---
Prov
Slot
Card Type
----
---------
0
GE24RJ
1
GE24RJ
2
GE24RJ
3
GE24RJ
4
CFC960
5
-
Figure 152. SHOW CARD Command
State
-------------------
UP-UP-Online
UP-UP-Online
UP-UP-Online
UP-UP-Online
UP-UP-Online (Active)
-
Faults
------
-
-
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents