Automatic Mdix Detection; Straight-Through Or Crossover Cabling; Table 14. Twisted Pair Cable For The At-Sbx31Gp24 Line Card - Allied Telesis SwitchBlade x3106 Installation Manual

Table of Contents

Advertisement

Table 14. Twisted Pair Cable for the AT-SBx31GP24 Line Card

Cable Type
Standard TIA/EIA 568-
B-compliant Category 3
shielded or unshielded
cabling with 100 ohm
impedance and a
frequency of 16 MHz.
Standard TIA/EIA 568-
A-compliant Category 5
shielded or unshielded
cabling with 100 ohm
impedance and a
frequency of 100 MHz.
Standard TIA/EIA 568-
B-compliant Enhanced
Category 5 (Cat 5e)
shielded or unshielded
cabling with 100 ohm
impedance and a
frequency of 100 MHz.
Standard TIA/EIA 568-
B-compliant Category 6
or 6a shielded cabling.
Automatic MDIX
Detection
Straight-through
or Crossover
Cabling
SwitchBlade x3106 Chassis Switch and AT-SBx31CFC960 Card Installation Guide
10Mbps
Non-
PoE
PoE+
PoE
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
The 10/100/1000 Mbps twisted-pair ports on the AT-SBx31GT24, AT-
SBx31GT40, and AT-SBx31GP24 Line Cards are IEEE 802.3ab compliant
and feature automatic MDIX detection when operating at 10 or 100 Mbps.
(Automatic MDIX detection does not apply to 1000 Mbps.) This feature
automatically configures the ports to MDI or MDI-X depending on the
wiring configurations of the end nodes.
You may not disable automatic MDIX detection on the ports. For automatic
MDIX detection to work properly, it must also be present on the network
devices. Ports connected to network devices that do not support automatic
MDIX detection default to MDIX.
Here are the guidelines on whether to use straight-through or crossover
cables to connect network devices to the line cards:
You may use straight-through cables on ports that are connected
to network devices that operate at 1000 Mbps.
100Mbps
Non-
PoE
PoE+
PoE
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
1000Mbps
Non-
PoE
PoE+
PoE
No
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes