SwitchBlade x3106 Chassis Switch and AT-SBx31CFC960 Card Installation Guide
System
Table 1. LEDs on the AT-SBxPWRSYS1 and AT-SBxPWRSYS2 AC
LED
State
Solid Green
AC
Off
Solid Green
DC
Off
Solid Amber The power supply has detected a fault condition,
Fault
Off
The LEDs on the AT-SBxPWRSYS1 DC System Power Supply are
described in Table 2.
Table 2. LEDs on the AT-SBxPWRSYS1 DC System Power Supply
LED
State
Solid Green
DC
IN
Off
Solid Green
DC
OUT
Off
Solid Amber The power supply has detected a fault condition,
Fault
Off
System Power Supplies
Description
The power supply is receiving AC power that is
within the normal operating range.
The power supply is not receiving power from the
AC power source.
The DC power that the module is providing to the
chassis components is within the normal
operating range.
The power supply is not generating DC power or
the power is outside the normal operating range.
such as an under-voltage or over-temperature
condition.
The power supply is operating normally or is
powered off.
Description
The power supply is receiving DC power that is
within the normal operating range.
The power supply is not receiving power from the
DC power source.
The DC power that the module is providing to the
chassis components is within the normal
operating range.
The power supply is not generating DC power or
the power is outside the normal operating range.
such as an under-voltage or over-temperature
condition.
The power supply is operating normally or is
powered off.
27