Entering The Management Software Commands; Figure 150: Show Psu Command - Allied Telesis SwitchBlade x3106 Installation Manual

Table of Contents

Advertisement

4. Press Enter. You are prompted for a user name and password.
5. Enter the default user name and password. They are "manager" and
Entering the
To confirm the operations of the chassis with the commands in the
management software, perform the following procedure:
Management
Software
1. To display the status of the power supplies, enter the SHOW PSU
Commands
2. To display the state of the fan module, enter the SHOW FANMODULE
SwitchBlade x3106 Chassis Switch and AT-SBx31CFC960 Card Installation Guide
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
"friend" (without the quotes), respectively
Note
User names and passwords are case sensitive.
The local management session starts and the command line interface
(CLI) prompt is displayed.
command.
An example of the status information is shown in Figure 150. The
power supplies are operating normally when the states are UP-UP. If
there is a problem with a power supply, refer to "AT-SBxPWRSYS1,
AT-SBxPWRSYS2, or AT-SBxPWRPOE1 AC Power Supply" on
page 228 or "AT-SBxPWRSYS1 DC System Power Supply" on
page 230 for troubleshooting suggestions.
SHOW PSU
--- Power Supply Units ---
Slot Type
State
A
POE
UP-UP
B
POE
UP-UP
C
System
UP-UP
D
System
UP-UP
Figure 150. SHOW PSU Command
command.
Temp (C)
38
38
38
38
213