Chapter 12: Troubleshooting
242
flashing amber on the inactive master card.
Check to be sure that the operating parameters on the terminal or
the terminal emulation program have been set correctly. The
default settings for the RJ-45 serial terminal port are located in
"Using Local Management to Verify the Chassis" on page 212.
Check to be sure that the terminal emulator application is
compatible with a VT-100 terminal.
Fault Condition 5: The controller card has an onboard battery that it uses
to maintain the date and time when the chassis is powered off or reset. If
you manually set the date and time but the card loses the information after
you power off or reset the unit, you may have forgotten to remove the
battery insulator when you installed the card in the chassis. The insulator
is shown in Figure 71 on page 130. The only way to remedy the problem is
to remove the controller card from the chassis and remove the battery
insulator. For instructions, refer to "Replacing the AT-SBx31CFC960
Controller Fabric Card" on page 269.