Disabling VCStack

awplus> show stack
% Warning: Stacking is currently disabled
Virtual Chassis Stacking summary information
ID
Pending ID
1
-
Operational Status
Stack MAC address
Caution
You must reset the switch to disable the VCStack feature. If the
switch is already connected to a live network, some network traffic
may be lost.
To disable the VCStack feature to use the switch as stand-alone unit,
perform the following procedure:
1. Start a local management session. Refer to "Starting a Local
Management Session" on page 81 for instructions.
2. Enter the SHOW STACK command to display the status of the
VCStack feature. Figure 41 is an example of the command.
MAC address
000c.2527.aba6
Figure 41. SHOW STACK Command
3. Review the following items:
If the Operational Status is "Stacking Hardware Disabled," the
VCStack feature is already disabled on the switch and the SFP+
stacking slots may be used with regular SFP or SFP+ transceivers.
If the Operational Status is "Standalone Unit," as shown in Figure
41 on page 83, the VCStack feature is active on the unit. You must
disable it by performing the steps in the rest of this procedure
before you can use the SFP+ stacking slots with regular SFP or
SFP+ transceivers. The reason the status says "standalone" is
because the switch considers itself a stack of one switch.
4. Move to the Global Configuration mode by entering the ENABLE and
CONFIGURE TERMINAL commands, as shown in Figure 42.
Priority
Status
128
Ready
Stacking hardware disabled
000c.2527.aba6
AT-IE510-28GSX Installation Guide
Role
Active Master
83