Chapter 13: Replacing Modules
Replacing the AT-SBxPWRSYS1, AT-SBxPWRSYS2, or AT-
SBxPWRPOE1 AC Power Supply
248
This section contains the procedure for removing or replacing the AT-
SBxPWRSYS1, AT-SBxPWRSYS2, or AT-SBxPWRPOE1 AC Power
Supply in the AT-SBx3106 Chassis.
Note
The illustrations in the procedure show the AT-SBxPWRSYS1 AC
Power Supply. The procedure is the same for all AC power supplies.
Note
Allied Telesis recommends creating a backup copy of the database
file of the chassis with the BACKUP DATABASE FILE command
before removing or replacing a power supply. For instructions, refer
to the Software Reference for SwitchBlade x3100 Series Switches.
Note
The power supplies are hot swappable.
To replace the AT-SBxPWRSYS1, AT-SBxPWRSYS2, or AT-
SBxPWRPOE1 AC Power Supply in the chassis, perform the following
procedure:
1. Disconnect the AC power cord for the power supply from the AC
power source and the corresponding AC socket on the back panel of
the chassis. The figure in Figure 153 on page 249 shows the removal
of the power cord from connector D, which corresponds to slot D on
the front panel.