3-42 Chapter 3
GSE Scale Systems
P995 – P997: Scale Motion (Model 650 Compatibility)
Provided only for backward compatibility with the GSE 650 Series upload
files. Selections entered here for scale's 2, 3 and 4 will be reflected in
P994. For example, enabling motion delay for scale #2 at P995 (by
entering a value of '1') will result in scale #2 appearing at P994.
P998: Continuous Transmit Enable
Enables the custom transmit for continuous transmission. The continuous
transmit interval is specified at P980 or through use of the %I macro
command.
P999: Transmit Table Limited Access
Enables the contents of the custom transmit table to be blocked from
viewing, downloading or editing if only the limited access code specified at
P402 was used to enter the setup mode.
P1000: Transmit Entry Table
Begins the custom transmit data table.
S
ETPOINTS
The setpoint parameters provide configuration of physical and logical
input/output.
P5099: Setpoint Instance
Sets the setpoint# in effect when accessing the remainder of the setpoint
configuration parameters P5100 à P5150.
P5100: Setpoint Mode
Selects whether the setpoint is configured as an Output, Input or
Disabled setpoint. The mode selected will determine which of the
subsequent setpoint setup parameters will be available for configuration.
P5101: Setpoint Name
Assigns a name to the setpoint for documentation purposes.
P5110: Activation Condition
Selects the setpoint's activation criteria.
P5111: Activation Delay
Assigns an activation delay (in seconds) before the setpoint will become
active once the activation criteria is met.
P5112: Activation Macro#
Selects the macro to be invoked when the setpoint becomes activated.
P5113: Activation Motion
Selects whether the activation of the setpoint will be motion delayed or
ignored.