Testing The Scr Module - GSE 60 SERIES Technical Reference Manual

Programmable process controllers
Table of Contents

Advertisement

"Delay Input", the next channel as a "Delay Output". Additional SCR
modules can be added by configuring successive PDIO channels as
"Delay Outputs" (only one "Delay Input" channel is required for multiple
SCR modules). Refer to page 3-41 for complete configuration details.
T
T
SCR M
ESTING
HE
To test an SCR module configured for output on channel #2:
1. Select the standard weigh mode (i.e. gross weight display).
2. Key In 50.2 [SELECT] to select the pulse width parameter.
3. Key In 1 [ENTER] to enter a pulse width of 1 ms.
4. Key In 51.2 [SELECT] to select the delay output parameter.
5. Key In 4 [ENTER] to enter a pulse output delay of 4 ms.
6. Key In 78 [SELECT] to select the manual setpoint control mode.
7. Key In 132 [ENTER] to select setpoint 132 for manual control.
This setpoint may have no effect if setpoint 132 is configured as an
output.
8. Press [F5] to activate setpoint 132 (runs device).
9. Press [F3] to deactivate setpoint 132 (stops device).
10. Press [SELECT] to return to the standard weigh mode.
If P862 is not configured for gating, the SCR output activates
immediately upon assigning a value to the delay output pulse (P51.2).
ODULE
60 Series Technical Reference Manual
Options 13-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents