GSE 60 SERIES Technical Reference Manual page 594

Programmable process controllers
Table of Contents

Advertisement

D-18 Appendix D
P
S
ARAMETER
ELECTION
P61104.6
150%
P61104.7
175%
P61104.8
0%
P61104.9
-25%
P61104.10
-50%
P61104.11
-75%
P61104.12
-100%
P61104.13
-125%
P61104.14
-150%
P61104.15
-175%
P61105.
0
P61106.0
25
P61106.1 †
50
P61106.2
100
P61106.3
200
P61107.
1.000000
P61110.
xxxxxx
P61111.
xxxxxx
P61112.
xxxxxx
P61113.
x.xxxxxx
P61114.
x.xxxxxx
P61115.
x.xxxxxx
P61116.
x.xxxxxx
P61117.
xxxxxx
P61118.
xxxxxx
P61119.
xxxxxx
P61120.
xxxxxx
P61121.
xxxxxx
P61122.
xxxxx
P61123.
BckUp GOOD!
P61130.
xxxxxx
P61131.
xxxxxx
P61132.
xxxxxx
P61133.
xxxxxx
P61134.
xxxxxx
P61135.
xxxxxx
P61136.
xxxxxx
P61137.
xxxxxx
P61138.
xxxxxx
P61139.
xxxxxx
P61150.
0
P61151.
2.000000
P61152.
2.000000
P61153.
2.000000
P61154.
2.000000
P61155.
2.000000
P61156.
2.000000
P61157.
2.000000
P61158.
2.000000
P61159.
100.0000
P61160.
2.000000
P61200.1 †
1
P61200.2
2
P61200.3
3
P61200.4
4
P61201.
xxxxx
P61202.
xxxxx
P61203.
xxxxx
P61204.
xxxxx
P61205.
xxxxx
GSE Scale Systems
D
(560 S
)
ESCRIPTION
ERIES
Fine Zero Calibration
Coarse Gain Calibration
Enter 1 à 4
Fine Gain Calibration
Zero Adjust 25
Enter Factory Determined Value
Zero Adjust 50
Enter Factory Determined Value
Zero Adjust 100
Enter Factory Determined Value
Gain Adjust 1
Enter Factory Determined Value
Gain Adjust 2
Enter Factory Determined Value
Gain Adjust 4
Enter Factory Determined Value
Gain Adjust 8
Enter Factory Determined Value
Analog In 1 NR Offset
Enter Factory Determined Value
Analog In 2 NR Offset
Enter Factory Determined Value
Analog In 4 NR Offset
Enter Factory Determined Value
Analog In 8 NR Offset
Enter Factory Determined Value
Voltage Reference Comp.
Enter Factory Determined Value
Multi-Scale Serial Number
Enter Serial Number
A/D Calibration Backup
First Linearization Weight
First Linearization Factor
Second Linearization Weight
Second Linearization Factor
Third Linearization Weight
Third Linearization Factor
Fourth Linearization Weight
Fourth Linearization Factor
Fifth Linearization Weight
Fifth Linearization Factor
Number of Load Cells
Load Cell #1 F.S mV/V Rating
Load Cell #2 F.S. mV/V Rating
Load Cell #3 F.S. mV/V Rating
Load Cell #4 F.S. mV/V Rating
Load Cell #5 F.S. mV/V Rating
Load Cell #6 F.S. mV/V Rating
Load Cell #7 F.S. mV/V Rating
Load Cell #8 F.S. mV/V Rating
Load Cell Full Scale Capacity
Average Load Cell mV/V Rating
Analog# for P61201 à P61207
Enter 1 à 4
Analog Zero Ref. (0-10V)
Analog Gain (0-10V)
Analog Zero Ref. (0-20mA)
Analog Gain (0-20mA)
Analog Zero Ref. (4-20mA)
P
S
ARAMETER
ELECTION
P61206.
xxxxx
P61207.
xxxxx
P62000.
P62001.
P62002.
P62010.1 †
1
P62010.2
2
P62010.3
3
P62010.4
4
P62011.
P62012.
P62013.
P64000.
P64001.
P64100.
0
P64101.
0
P64102.
None!
P64103.0
Off
P64103.1
Comm1
P64103.2
Comm2
P64103.3
Comm3
P65000.
P65001.
P65002.
P65003.
P65010.
P62002.
Table D-3: 660 Series Parameter Setup
P
S
ARAMETER
ELECTION
Scale Configuration
P108.01
Scale 1
P108.02
Scale 2
P108.03
Scale 3
D
(560 S
)
ESCRIPTION
ERIES
Analog Gain (4-20mA)
Analog Option Serial Number
Display Test
Press [ENTER]
Optional RAM Test
Press [ENTER]
2
EEPROM (E
) Test
Press [ENTER]
Analog Output Test for
P62011 à P62013
Enter 1 à 4
0-10V Analog Output Test
Press [ENTER]
0-20mA Analog Output Test
Press [ENTER]
4-20mA Analog Output Test
Press [ENTER]
Send Setup
Press [ENTER]
Send Setup & Parameter
Values
Press [ENTER]
Upload Line Count
Upload Error Count
First Upload Error
Upload Debug Output
2
Copy EEPROM (E
)
Press [ENTER]
Complete Factory Default
Press [ENTER]
Factory Default (except CAL)
Press [ENTER]
Script File
Press [TARE], then [ENTER]
Database Reset
Press [ENTER]
2
EEPROM (E
) Test
Press [ENTER]
D
(660 S
)
ESCRIPTION
ERIES
Scale Instance Selection
Enter 1 à 8